A STUDY ON HEAT OUTPUT FOR JIS A 1310 “TEST METHOD FOR FIRE PROPAGATION OVER BUILDING FAÇADES”

2018 ◽  
Vol 83 (753) ◽  
pp. 851-860
Author(s):  
Yuhei NISHIO ◽  
Takafumi NOGUCHI ◽  
Hideki YOSHIOKA ◽  
Manabu KANEMATSU
2016 ◽  
Vol 46 ◽  
pp. 01002 ◽  
Author(s):  
István Móder ◽  
Ádám Varga ◽  
Péter Geier ◽  
Bálint Vágó ◽  
Edit Rajna

2016 ◽  
Vol 38 (3) ◽  
pp. 269-286
Author(s):  
David Johnston ◽  
David Glew ◽  
Dominic Miles-Shenton ◽  
Moaad Benjaber ◽  
Richard Fitton

In the UK, approximately 16% of the energy use can be attributed to domestic wet central heating systems. Government financial support and advances in technology have led to boilers becoming more efficient and a range of technologies are now available that claim to be able to improve the efficiency of domestic wet central heating systems. One such low cost technology is a passive deaerator. This article presents the results obtained from installing a passive deaerator on the closed loop of a gas-fired wet central heating system, under controlled conditions in the Salford Energy House. The results indicate that although marginally less heat output was required from the boiler when the passive deaerator was operating, these savings are more or less out weighted by the boiler short cycling more frequently. Consequently, the overall reduction is gas consumption achieved by utilising the passive deaerator device is only of the order of 0.5%; this scale of savings may just be a consequence of measurement noise. The implications are that although a marginal benefit may be attributed to these products, if short cycling takes place, then these savings may become insignificant. Practical application: This article describes a test method that has been used to quantify the energy savings that could be achieved by installing a passive deaerator on the closed loop of a wet central heating system. Although the results indicate that the energy savings associated with using such a device are likely to be marginal, the test method described could be used to test a range of other devices that claim to improve the performance of domestic wet central heating systems, to directly compare before and after performance.


2011 ◽  
Vol 17 (36) ◽  
pp. 537-542
Author(s):  
Hideki YOSHIOKA ◽  
Hsin-Chieh YANG ◽  
Masamichi TAMURA ◽  
Masashi YOSHIDA ◽  
Takafumi NOGUCHI ◽  
...  

2019 ◽  
pp. 52-56
Author(s):  
Yu.F. Glukhov ◽  
N.V. Krutikov ◽  
A.V. Ivanov ◽  
N.P. Muravskaya

We have studied and analyzed status and metrological supervision of blood glucose monitors, individual devices for a person’s blood glucose level measurement. It has been indicated that nowadays blood glucose monitors like other individual devices for medical measurement are not allowed to be involved in telemedicine public service. This accounts for absence of metrological supervision with these measurement devices in telemedicine. In addition, the key problem is absence of safe methods and means of remote verificaition, calibration and transmission of measurement data to health care centers. The article offers a remote test method for blood glucose monitors using a number of resistors with values correlating with measured blood glucose level. The available method has been successfully trialed in real practice.


Author(s):  
Tran Minh Hieu ◽  
Nguyen Duong Ngoc Mai Chi

This study applied SERVQUAL scale of Parasuraman et al to measure factors affecting customer satisfaction on service quality at Vietnam Technological and Commercial Joint Stock Bank - An Giang Branch (Techcombank An Giang). The study was conducted to survey 207 customers who have been using the service at Techcombank An Giang. The survey results were analyzed by the Cronbach's Alpha reliability test method, then used Exploratory factor analysis (EFA) to verify and evaluate the scale of service quality. The results of the regression analysis show that customer's satisfaction about service quality at Techcombank An Giang includes four factors: The factor with the highest level is the Empathy with Beta = 0.253, the second of factor is the Responsibility with Beta = 0.248, ranked third in the influence level is the Tangible with Beta = 0.235, and the lowest impact level is the Reliability with Beta = 0.144. The research also uses statistical methods to describe and test the differences of demographic factors with customer's satisfactionon service quality.The analysis results show that there is no difference between customer's satisfaction on service quality and factors such as gender, age, income, number of transaction banks, regular transaction banks, and time to use the service at Techcombank An Giang. Through the research results, the author would like to propose some ideas to improve the quality of services, thereby attracting new customers and importantly, keeping traditional customers because the development orientation of Techcombank is to take care of old customers to cross sell other products of the bank. The Stud results offer a basis for the branch to identify the factors influencing customer satisfaction on their service quality, thereby having an appropriate strategy to improve customer satisfaction.


TAPPI Journal ◽  
2009 ◽  
Vol 8 (6) ◽  
pp. 24-28
Author(s):  
CORY JAY WILSON ◽  
BENJAMIN FRANK

TAPPI test T811 is the specified method to ascertain ECT relative to box manufacturer’s certification compliance of corrugated fiberboard under Rule 41/ Alternate Item 222. T811 test sample heights were derived from typical board constructions at the time of the test method’s initial development. New, smaller flute sizes have since been developed, and the use of lighter weight boards has become more common. The T811 test method includes sample specifications for typical A-flute, B-flute, and C-flute singlewall (and doublewall and triplewall) structures, but not for newer thinner E-flute or F-flute structures. This research explores the relationship of ECT sample height to measured compressive load, in an effort to determine valid E-flute and F-flute ECT sample heights for use with the T811 method. Through this process, it identifies challenges present in our use of current ECT test methods as a measure of intrinsic compressive strength for smaller flute structures. The data does not support the use of TAPPI T 811 for ECT measurement for E and F flute structures, and demonstrates inconsistencies with current height specifi-cations for some lightweight B flute.


TAPPI Journal ◽  
2019 ◽  
Vol 18 (3) ◽  
pp. 161-169
Author(s):  
Doug Cash ◽  
Benjamin Frank

The corrugated industry typically quantifies crush resistance using the Concora corrugated medium test (CMT) on fluted medium or flat crush on combined board. These tests compress the materials until the point of complete failure of the flutes. Combined board elastically resists crushing forces until a certain point, the hardness of the structure, while additional load causes permanent damage and deformation. This study investigates how hardness can be measured directly from a load curve collected during CMT (or flat crush) testing and how it varies throughout the North American paper supply. It also explores how hardness correlates with the values obtained from the newly developed S-test. This new test method deserves further study as a potentially more appropriate specification for crush resistance of corrugated medium.


Sign in / Sign up

Export Citation Format

Share Document