scholarly journals STUDY ON TORSIONAL VIBRATION OF HIGH RISE BUILDING IN WIND : Part II・Dynamic Model Test in Shear Flow in Wind Tunnel

1976 ◽  
Vol 249 (0) ◽  
pp. 35-40
Author(s):  
TAKESHI OHKUMA ◽  
AKIO KANAYA
2021 ◽  
Vol 11 (8) ◽  
pp. 3315
Author(s):  
Fabio Rizzo

Experimental wind tunnel test results are affected by acquisition times because extreme pressure peak statistics depend on the length of acquisition records. This is also true for dynamic tests on aeroelastic models where the structural response of the scale model is affected by aerodynamic damping and by random vortex shedding. This paper investigates the acquisition time dependence of linear transformation through singular value decomposition (SVD) and its correlation with floor accelerometric signals acquired during wind tunnel aeroelastic testing of a scale model high-rise building. Particular attention was given to the variability of eigenvectors, singular values and the correlation coefficient for two wind angles and thirteen different wind velocities. The cumulative distribution function of empirical magnitudes was fitted with numerical cumulative density function (CDF). Kolmogorov–Smirnov test results are also discussed.


2018 ◽  
Vol 174 ◽  
pp. 391-403 ◽  
Author(s):  
R. Sheng ◽  
L. Perret ◽  
I. Calmet ◽  
F. Demouge ◽  
J. Guilhot

2013 ◽  
Vol 12 (2) ◽  
pp. 079-086
Author(s):  
Grzegorz Bosak

The paper summarizes the results of wind tunnel tests of the influence of aerodynamic interference on wind action of a high-rise building design in Warsaw. Measurements were accomplished in Wind Engineering Laboratory of Cracow University of Technology. Wind pressures on external surfaces of the building model were acquired in two different situations. Firstly, only the building model was placed in the tunnel working section, secondly, the building model with the nearest surroundings was taken under consideration. A study of the character of wind action differences caused by the nearest surroundings of the building was the main aim of the paper. Wind pressure coefficients on the external building surfaces and the difference of horizontal wind action on full scale were compared.


Author(s):  
CHARLES C. K. CHENG ◽  
K. M. LAM ◽  
RICHARD K. K. YUEN ◽  
S. M. LO

2020 ◽  
Vol 2020 ◽  
pp. 1-24
Author(s):  
Fu-Bin Chen ◽  
Xiao-Lu Wang ◽  
Yun Zhao ◽  
Yuan-Bo Li ◽  
Qiu-Sheng Li ◽  
...  

High-rise buildings are very sensitive to wind excitations, and wind-induced responses have always been the key factors for structural design. Facade openings have often been used as aerodynamic measures for wind-resistant design of high-rise buildings to meet the requirement of structural safety and comfort. Obvious wind speed amplifications can also be observed inside the openings. Therefore, implementing wind turbines in the openings is of great importance for the utilization of abundant wind energy resources in high-rise buildings and the development of green buildings. Based on numerical simulation and wind tunnel testing, the wind loads and wind speed amplifications on high-rise buildings with openings are investigated in detail. The three-dimensional numerical simulation for wind effects on high-rise building with openings was firstly carried out on FLUENT 15.0 platform by SST k − ε model. The mean wind pressure coefficients and the wind flow characteristics were obtained. The wind speed amplifications at the opening were analyzed, and the distribution law of wind speed in the openings is presented. Meanwhile, a series of wind tunnel tests were conducted to assess the mean and fluctuating wind pressure coefficients in high-rise building models with various opening rates. The variation of wind pressure distribution at typical measuring layers with wind direction was analyzed. Finally, the wind speed amplifications in the openings were studied and verified by the numerical simulation results.


2012 ◽  
Vol 446-449 ◽  
pp. 3889-3893
Author(s):  
Bin Zhao ◽  
Juan He ◽  
Hui Gao ◽  
Xu Gang Chen

For many high-rising buildings, large local space is very useful for its special function needs, such as conference hall and hotel lobby. The shake table test results of a high-rising building with large local space show that the dynamic characteristics of such structure are complex and the torsional mode becomes the first mode, while the torsional responses under earthquake excitation, especially of the floor just above the large local space, are very remarkable. In this paper, the bidirectional Tuned Mass Damper (TMD) is employed for reducing the torsional vibration of such complex high-rise building structure. A reduced-scale model is design and constructed. A series of shake table tests are carried out and the test results indicate that the TMD system is very effective in torsional vibration control of structural system.


Sign in / Sign up

Export Citation Format

Share Document