scholarly journals Mortality predictors in acute kidney injury patients who underwent continuous venovenous hemodiafiltration: A retrospective, single-center study

Author(s):  
Alper Alp ◽  
Hakan Akdam ◽  
Harun Akar ◽  
Yavuz Yeniçerioğlu

Continuous renal replacement therapy (CRRT) is an increasingly preferred treatment that is easier to use in patients with hemodynamic impairment and can be applied in critical care settings. There are various subtypes of CRRT, one of which is continuous venovenous hemodiafiltration (CVVHDF). In this study, we examined the general characteristics of intensive care patients who underwent CVVHDF. Methods. The clinical and biochemical data of 123 patients who underwent CVVHDF in the intensive care units of our center between February 2012 and November 2014 were analyzed retrospectively. Patients who died during the course of therapy were compared with those who survived. Results. The study included 123 patients, 73 males (59.3%) and 50 females (40.7%). The mean age was 64.4 years. Eighty-eight patients (71.5%) died during CVVHDF while 35 patients survived (28.5%). Hemodynamic parameters such as systolic and diastolic arterial blood pressure, mean arterial pressure, and pulse pressure were significantly lower in patients who died compared to survivors (p<0.001). Mean lactic acid level was significantly higher in the deceased group than in the surviving group (8.54 mmol/L vs. 3.68 mmol/L, p<0.001, chi-square test). Conclusions. Low bicarbonate level, low systolic arterial blood pressure, and older age were significant independent predictors of mortality in this study. Mortality rates were significantly higher among patients with lactic acidosis and those over 66 years of age. Lactic acid levels can be used to predict mortality in patients undergoing CVVHDF.

2003 ◽  
Vol 98 (6) ◽  
pp. 1338-1344 ◽  
Author(s):  
Gilles Boccara ◽  
Alexandre Ouattara ◽  
Gilles Godet ◽  
Eric Dufresne ◽  
Michèle Bertrand ◽  
...  

Background Terlipressin, a precursor that is metabolized to lysine-vasopressin, has been proposed as a drug for treatment of intraoperative arterial hypotension refractory to ephedrine in patients who have received long-term treatment with renin-angiotensin system inhibitors. The authors compared the effectiveness of terlipressin and norepinephrine to correct hypotension in these patients. Methods Among 42 patients scheduled for elective carotid endarterectomy, 20 had arterial hypotension following general anesthesia that was refractory to ephedrine. These patients were the basis of the study. After randomization, they received either 1 mg intravenous terlipressin (n = 10) or norepinephrine infusion (n = 10). Beat-by-beat recordings of systolic arterial blood pressure and heart rate were stored on a computer. The intraoperative maximum and minimum values of blood pressure and heart rate, and the time spent with systolic arterial blood pressure below 90 mmHg and above 160 mmHg, were used as indices of hemodynamic stability. Data are expressed as median (95% confidence interval). Results Terlipressin and norepinephrine corrected arterial hypotension in all cases. However, time spent with systolic arterial blood pressure below 90 mmHg was less in the terlipressin group (0 s [0-120 s] vs. 510 s [120-1011 s]; P &lt; 0.001). Nonresponse to treatment (defined as three boluses of terlipressin or three changes in norepinephrine infusion) occurred in zero and eight cases (P &lt; 0.05), respectively. Conclusions In patients who received long-term treatment with renin-angiotensin system inhibitors, intraoperative refractory arterial hypotension was corrected with both terlipressin and norepinephrine. However, terlipressin was more rapidly effective for maintaining normal systolic arterial blood pressure during general anesthesia.


PEDIATRICS ◽  
1982 ◽  
Vol 69 (5) ◽  
pp. 583-586
Author(s):  
Ronald N. Goldberg ◽  
Steven L. Goldman ◽  
R. Eugene Ramsay ◽  
Rosalyn Feller

In experimental animals neurologic damage may occur during seizure activity whether the seizure is accompanied by motor activity and hypoxemia or whether the animal is paralyzed and normoxemic. These findings suggest that it may be important to detect seizure activity in the paralyzed neonate. Nine infants who were mechanically ventilated and paralyzed with pancuronium had their condition diagnosed as seizure activity. Vital signs were continuously monitored and six infants had either oxygen saturation or transcutaneous oxygen measured during seizure activity. For the group as a whole, rhythmic fluctuations in vital signs, cardiac rhythm, and oxygenation occurred every four minutes (range one to seven minutes) and lasted two minutes (range one to four minutes). In seven patients whose seizures were not accompanied by cardiac arrhythmias the following mean increases were noted: systolic arterial blood pressure, 15 mm Hg (range 7 to 36 mm Hg); heart rate, ten beats per minute (-11 to 30/min); oxygen saturation, 12% (range 4% to 20%); and transcutaneous oxygen, 31 mm Hg (range 14 to 45 mm Hg). Seizures in the two patients with cardiac arrhythmias were accompanied by a decrease in systolic arterial blood pressure of 27 mm Hg (range 15 to 40 mm Hg) and in oxygen saturation of 24% (range 20% to 28%). The presence of rhythmic fluctuation in vital signs and oxygenation should alert the physician to the possibility of seizure activity in the paralyzed neonate.


2004 ◽  
Vol 286 (6) ◽  
pp. H2408-H2415 ◽  
Author(s):  
Steven E. Whitesall ◽  
Janet B. Hoff ◽  
Alan P. Vollmer ◽  
Louis G. D'Alecy

Radiotelemetry of mouse blood pressure accurately monitors systolic pressure, diastolic pressure, heart rate, and locomotor activity but requires surgical implantation. Noninvasive measurements of indirect systolic blood pressure have long been available for larger rodents and now are being reported more frequently for mice. This study compared mouse systolic arterial blood pressure measurements using implanted radiotelemetry pressure transducer with simultaneous tail-cuff measurements in the same unanesthetized mice. The pressure range for comparison was extended by inducing experimental hypertension or by observations of circadian elevations between 3 AM and 6 AM. Both trained and untrained tail-cuff operators used both instruments. Every effort was made to follow recommended manufacturer's instructions. With the initial flow-based tail-cuff instrument, we made 671 comparisons (89 sessions) and found the slope of the linear regression to be 0.118, suggesting poor agreement. In an independent assessment, 277 comparisons (35 sessions) of radiotelemetry measurements with the pulse based tail-cuff instrument were made. The slope of the linear regression of the simultaneous measurements of systolic pressures was 0.98, suggesting agreement. Bland-Altman analysis also supported our interpretation of the linear regression. Thus although reliable systolic pressure measurements are possible with either tail-cuff or radiotelemetry techniques, in our hands some tail-cuff instruments fail to accurately detect elevated blood pressures. These data, however, do not distinguish whether this instrument-specific tail-cuff failure was due to operator or instrument inadequacies. We strongly advise investigators to obtain an independent and simultaneous validation of tail-cuff determinations of mouse blood pressure before making critical genotyping determinations.


2019 ◽  
Vol 114 (1) ◽  
pp. S578-S579
Author(s):  
Jennifer L. Peng ◽  
Sarah M. Russell ◽  
Hani Shamseddeen ◽  
Carla D. Kettler ◽  
Caitriona A. Buckley ◽  
...  

Author(s):  
Jaswinder Kaur ◽  
Siddharth Bhargava ◽  
Puneet Aulakh Pooni ◽  
Deepak Bhat ◽  
Gurdeep S. Dhooria ◽  
...  

AbstractIntra-arterial blood pressure (IABP) measurement, although considered the gold standard in critically ill children, is associated with certain risks and lacks widespread availability. This study was conducted to determine the differences and agreements between oscillometric non-invasive blood pressure (NIBP) and invasive IABP measurements in children. Inclusion criteria consisted of children (from 1 month to 18 years) admitted to the pediatric intensive care unit (PICU) of a teaching hospital who required arterial catheter insertion for blood pressure (BP) monitoring. The comparison between IABP and NIBP was studied using paired t-test, Bland–Altman analysis, and Pearson's correlation coefficient. In total, 4,447 pairs of simultaneously recorded hourly NIBP and IABP measurements were collected from 65 children. Mean differences between IABP and NIBP were −3.6 ± 12.85, −4.7 ± 9.3, and −3.12 ± 9.30 mm Hg for systolic, diastolic, and mean arterial BP, respectively (p < 0.001), with wide limits of agreement. NIBP significantly overestimated BP (p < 0.001) in all three BP states (hypotensive, normotensive, and hypertensive), except systolic blood pressure (SBP) during hypertension where IABP was significantly higher. The difference in SBP was most pronounced during hypotension. The difference in SBP was significant in children <10 years (p < 0.001), with the maximum difference being in infants. It was insignificant in adolescents (p = 0.28) and underweight children (p = 0.55). NIBP recorded significantly higher BP in all states of BP except SBP in the hypertensive state. SBP measured by NIBP tended to be the most reliable in adolescents and underweight children. NIBP was the most unreliable in infants, obese children, and during hypotension.


Sign in / Sign up

Export Citation Format

Share Document