Biomechanical analysis of screw constructs for atlantoaxial fixation in cadavers: a systematic review and meta-analysis

2015 ◽  
Vol 22 (2) ◽  
pp. 151-161 ◽  
Author(s):  
Jerry Y. Du ◽  
Alexander Aichmair ◽  
Janina Kueper ◽  
Timothy Wright ◽  
Darren R. Lebl

OBJECT The unique and complex biomechanics of the atlantoaxial junction make the treatment of C1–2 instability a challenge. Several screw-based constructs have been developed for atlantoaxial fixation. The biomechanical properties of these constructs have been assessed in numerous cadaver studies. The purpose of this study was to systematically review the literature on the biomechanical stability achieved using various C1–2 screw constructs and to perform a meta-analysis of the available data. METHODS A systematic search of PubMed through July 1, 2013, was conducted using the following key words and Boolean operators: “atlanto [all fields]” AND “axial [all fields]” OR “C1–C2” AND “biomechanic.” Cadaveric studies on atlantoaxial fixation using screw constructs were included. Data were collected on instability models, fixation techniques, and range of motion (ROM). Forest plots were constructed to summarize the data and compare the biomechanical stability achieved. RESULTS Fifteen articles met the inclusion criteria. An average (± SD) of 7.4 ± 1.8 cadaveric specimens were used in each study (range 5–12). The most common injury models were odontoidectomy (53.3%) and cervical ligament transection (26.7%). The most common spinal motion segments potted for motion analysis were occiput–C4 (46.7%) and occiput–C3 (33.3%). Four screw constructs (C1 lateral mass–C2 pedicle screw [C1LM–C2PS], C1–2 transarticular screw [C1–C2TA], C1 lateral mass–C2 translaminar screw [C1LM-C2TL], and C1 lateral mass–C2 pars screw [C1LM–C2 pars]) were assessed for biomechanical stability in axial rotation, flexion/extension, and lateral bending, for a total of 12 analyses. The C1LM–C2TL construct did not achieve significant lateral bending stabilization (p = 0.70). All the other analyses showed significant stabilization (p < 0.001 for each analysis). Significant heterogeneity was found among the reported stabilities achieved in the analyses (p < 0.001; I2 > 80% for all significant analyses). The C1LM–C2 pars construct achieved significantly less axial rotation stability (average ROM 36.27° [95% CI 34.22°–38.33°]) than the 3 other constructs (p < 0.001; C1LM–C2PS average ROM 49.26° [95% CI 47.66°–50.87°], C1–C2TA average ROM 47.63° [95% CI 45.22°–50.04°], and C1LM–C2TL average ROM 53.26° [95% CI 49.91°–56.61°]) and significantly more flexion/extension stability (average ROM 13.45° [95% CI 10.53°–16.37°]) than the 3 other constructs (p < 0.001; C1LM–C2PS average ROM 9.02° [95% CI 8.25°–9.80°], C1–C2TA average ROM 7.39° [95% CI 5.60°–9.17°], and C1LM–C2TL average ROM 7.81° [95% CI 6.93°–8.69°]). The C1–C2TA (average ROM 5.49° [95% CI 3.89°–7.09°]) and C1LM–C2 pars (average ROM 4.21° [95% CI 2.19°–6.24°]) constructs achieved significantly more lateral bending stability than the other constructs (p < 0.001; C1LM–C2PS average ROM 1.51° [95% CI 1.23°–1.78°]; C1LM–C2TL average ROM −0.07° [95% CI −0.44° to 0.29°]). CONCLUSIONS Meta-analysis of the existing literature showed that all constructs provided significant stabilization in all axes of rotation, except for the C1LM–C2TL construct in lateral bending. There were significant differences in stabilization achieved in each axis of motion by the various screw constructs. These results underline the various strengths and weaknesses in biomechanical stabilization of different screw constructs. There was significant heterogeneity in the data reported across the studies. Standardized spinal motion segment configuration and injury models may provide more consistent and reliable results.

2011 ◽  
Vol 69 (suppl_1) ◽  
pp. ons1-ons7 ◽  
Author(s):  
Jae Taek Hong ◽  
Tomoyuki Takigawa ◽  
Ranjith Udayakunmar ◽  
Hun Kyu Shin ◽  
Peter Simon ◽  
...  

Abstract BACKGROUND: There have been no reports of biomechanical stability of C1-2 constructs after decortication of the C2 lamina. In addition, few studies have compared the stability of C2 laminar screw and pars screw constructs. OBJECTIVE: To compare the biomechanical stability of 3 different C1-2 construct conditions (C2 pars screw, C2 intralaminar screw, C2 intralaminar construct with C2 laminar decortication). METHODS: Fourteen fresh-frozen cadaveric cervical specimens (C1-3) were used. In 7 specimens, pure moments of 1.5 Nm were applied in flexion/extension, lateral bending, and axial rotation. Each specimen was tested in the normal state, in the destabilized state (after odontoidectomy and resection of transverse atlantal ligament), and after application of constructs. After kinematic study, these 7 specimens underwent axial pullout strength testing of pars screw and 50% decorticated C2 intralaminar screws. In another 7 specimens, insertion torque and pullout strength were measured to compare the pars screw and intact C2 intralaminar screw. RESULTS: There were no statistically significant differences between the intact C2 intralaminar and 50% decorticated C2 intralaminar screw constructs in terms of range-of-motion limitations. The C2 pars screw construct was significantly superior to the C2 laminar screw construct in lateral bending (P &lt; .01) and axial rotation (P &lt; .01) and equivalent to the C2 laminar screw construct in flexion/extension (P = .42). There was no significant pullout strength difference between the 3 kinds of C2 screw. CONCLUSION: The C1 lateral mass-C2 pars screws construct was stronger than the C1 lateral mass-C2 intralaminar screw construct. Decortication of C2 laminar (up to 50%) did not affect the immediate stability of the C1-2 construct.


2008 ◽  
Vol 9 (3) ◽  
pp. 296-300 ◽  
Author(s):  
Michael A. Finn ◽  
Daniel R. Fassett ◽  
Todd D. Mccall ◽  
Randy Clark ◽  
Andrew T. Dailey ◽  
...  

Object Stabilization with rigid screw/rod fixation is the treatment of choice for craniocervical disorders requiring operative stabilization. The authors compare the relative immediate stiffness for occipital plate fixation in concordance with transarticular screw fixation (TASF), C-1 lateral mass and C-2 pars screw (C1L-C2P), and C-1 lateral mass and C-2 laminar screw (C1L-C2L) constructs, with and without a cross-link. Methods Ten intact human cadaveric spines (Oc–C4) were prepared and mounted in a 7-axis spine simulator. Each specimen was precycled and then tested in the intact state for flexion/extension, lateral bending, and axial rotation. Motion was tracked using the OptoTRAK 3D tracking system. The specimens were then destabilized and instrumented with an occipital plate and TASF. The spine was tested with and without the addition of a cross-link. The C1L-C2P and C1L-C2L constructs were similarly tested. Results All constructs demonstrated a significant increase in stiffness after instrumentation. The C1L-C2P construct was equivalent to the TASF in all moments. The C1L-C2L was significantly weaker than the C1L-C2P construct in all moments and significantly weaker than the TASF in lateral bending. The addition of a cross-link made no difference in the stiffness of any construct. Conclusions All constructs provide significant immediate stability in the destabilized occipitocervical junction. Although the C1L-C2P construct performed best overall, the TASF was similar, and either one can be recommended. Decreased stiffness of the C1L-C2L construct might affect the success of clinical fusion. This construct should be reserved for cases in which anatomy precludes the use of the other two.


2020 ◽  
Vol 10 (20) ◽  
pp. 7291
Author(s):  
Soo-Bin Lee ◽  
Hwan-Mo Lee ◽  
Tae-Hyun Park ◽  
Sung Lee ◽  
Young-Woo Kwon ◽  
...  

Background: There are a few biomechanical studies that describe posterior fixation methods with pedicle screws (PS) and lateral mass screws (LMS); the combination of both screw types and their effect on an allograft spacer in a surgically treated cervical segment is unknown. Methods: Finite element model (FEM) analyses were used to investigate the effects of a hybrid technique using posterior PS and LMS. Stress distribution and subsidence risk from a combination of screws under hybrid motion control conditions, including flexion, extension, axial rotation, and lateral bending, were investigated to evaluate the biomechanical characteristics of different six-screw combinations. Findings: The load sharing on the allograft spacer in flexion mode was highest in the LMS model (74.6%) and lowest in the PS model (35.1%). The likelihood of subsidence of allograft spacer on C6 was highest in the screws from the distal LMS (type 5) model during flexion and extension (4.902 MPa, 30.1% and 2.189 MPa, 13.4%). In lateral bending, the left unilateral LMS (type 4) model screws on C5 (3.726 MPa, 22.9%) and C6 (2.994 MPa, 18.4%) yielded the greatest subsidence risks, because the lateral bending forces were supported by the LMS. In counterclockwise axial rotation, the left unilateral LMS (type 4) model screws on C5 (3.092 MPa, 19.0%) and C6 (3.076 MPa, 18.9%) demonstrated the highest subsidence risks. Conclusion: The asymmetrical ipsilateral use of LMS and posterior PS in lateral bending and axial rotation demonstrated the lowest stability and greatest subsidence risk. We recommend bilateral symmetrical insertion of LMS or posterior PS and posterior PS on distal vertebrae for increased stability and reduced risk of allograft spacer subsidence.


Neurosurgery ◽  
2006 ◽  
Vol 58 (3) ◽  
pp. 522-527 ◽  
Author(s):  
Aftab Karim ◽  
Debi Mukherjee ◽  
Murali Ankem ◽  
Jorge Gonzalez-Cruz ◽  
Donald Smith ◽  
...  

Abstract OBJECTIVE: Anterior lumbar interbody fusion (ALIF) has proven effective for indications including discogenic back pain, nonunion, and instability. Current practice involves posterior pedicle screw augmentation of the ALIF procedure (ALIF-PPS). This approach requires intraoperative repositioning of the patient for percutaneous posterior pedicle screw placement. We have developed a novel technique in which the ALIF procedure is augmented with anterior pedicle screws (APS; ALIF-APS). In this study, we introduce this new technique and compare the biomechanical stability of the novel ALIF-APS with the current standard ALIF-PPS. METHODS: The technique was demonstrated in a cadaveric L4–S1 specimen using neuronavigation and fluoroscopy. Plain radiographs and computed tomographic scans of the construct were obtained. Twelve cadaveric spines (7 men and 5 women) from donors with an average age of 81 years (range, 64–93 yr) were then harvested from L4–S1. Six specimens were dedicated to ALIF-APS constructs, and the remaining six were dedicated to ALIF-PPS constructs. The specimens were then studied at L5–S1 in the following steps: 1) intact form, 2) after anterior discectomy, 3) after implantation of titanium cages (ALIF), and 4) after APS or PPS fixation in conjunction with the ALIF. Measurements were obtained in axial rotation and left and right lateral bending flexion-extension. Data were normalized by calculating the ratio of the stiffness of the instrumented to the intact spine. Statistical analyses were then performed on the data. RESULTS: Radiographs and computed tomographic scans of the construct showed accurate placement of the APS at L5 and S1. The normalized data showed that ALIF-APS and ALIF-PPS had approximately equal stability in axial rotation (1.17 ± 0.43 versus 0.85 ± 0.14), lateral bending (0.93 ± 0.22 versus 0.95 ± 0.16), and flexion- extension (0.77 ± 0.13 versus 0.84 ± 0.2). Paired t test analysis did not show a significant difference between the biomechanical stiffness of ALIF-APS and ALIF-PPS in axial rotation, lateral bending, and flexion-extension. CONCLUSION: We demonstrate a new technique in a cadaveric specimen whereby the ALIF procedure is augmented with APS fixation using neuronavigation and fluoroscopy. Biomechanical evaluation of the constructs suggests that the ALIF-APS has comparable stability with ALIF-PPS. APS augmentation of ALIF has potential advantages over the current standard ALIF-PPS because it can 1) eliminate the patient repositioning step, 2) minimize the total number of incisions and the total operative time, and 3) protect against dislocation of the ALIF interbody graft or cage. Work is in progress to develop a low-profile system for the novel APS constructs described here.


2019 ◽  
Vol 30 (3) ◽  
pp. 314-322 ◽  
Author(s):  
Gilbert Cadena ◽  
Huy T. Duong ◽  
Jonathan J. Liu ◽  
Kee D. Kim

OBJECTIVEC1–2 is a highly mobile complex that presents unique surgical challenges to achieving biomechanical rigidity and fusion. Posterior wiring methods have been largely replaced with segmental constructs using the C1 lateral mass, C1 pedicle, C2 pars, and C2 pedicle. Modifications to reduce surgical morbidity led to the development of C2 laminar screws. The C1 posterior arch has been utilized mostly as a salvage technique, but recent data indicate that this method provides significant rigidity in flexion-extension and axial rotation. The authors performed biomechanical testing of a C1 posterior arch screw (PAS)/C2 pars screw construct, collected morphometric data from a population of 150 CT scans, and performed a feasibility study of a freehand C1 PAS technique in 45 cadaveric specimens.METHODSCervical spine CT scans from 150 patients were analyzed to determine the average C1 posterior tubercle thickness and size of C1 posterior arches. Eight cadavers were used to compare biomechanical stability of intact specimens, C1 lateral mass/C2 pars screw, and C1 PAS/C2 pars screw constructs. Paired comparisons were made using repeated-measures ANOVA and Holm-Sidak tests. Forty-five cadaveric specimens were used to demonstrate the feasibility and safety of the C1 PAS freehand technique.RESULTSMorphometric data showed the average craniocaudal thickness of the C1 posterior tubercle was 12.3 ± 1.94 mm. Eight percent (12/150) of cases showed thin posterior tubercles or midline defects. Average posterior arch thickness was 6.1 ± 1.1 mm and right and left average posterior arch length was 28.7 mm ± 2.53 mm and 28.9 ± 2.29 mm, respectively. Biomechanical testing demonstrated C1 lateral mass/C2 pars and C1 PAS/C2 pars constructs significantly reduced motion in flexion-extension and axial rotation compared with intact specimens (p < 0.05). The C1 lateral mass/C2 pars screw construct provided significant rigidity in lateral bending (p < 0.05). There was no statistically significant difference between the two constructs in flexion-extension, lateral bending, or axial rotation. Of the C1 posterior arches, 91.3% were successfully cannulated using a freehand technique with a low incidence of cortical breach (4.4%).CONCLUSIONSThis biomechanical analysis indicates equivalent stability of the C1 PAS/C2 pars screw construct compared with a traditional C1 lateral mass/C2 pars screw construct. Both provide significant rigidity in flexion-extension and axial rotation. Feasibility testing in 45 cadaveric specimens indicates a high degree of accuracy with low incidence of cortical breach. These findings are supported by a separate radiographic morphometric analysis.


2010 ◽  
Vol 13 (2) ◽  
pp. 234-239 ◽  
Author(s):  
Frank S. Bishop ◽  
Mical M. Samuelson ◽  
Michael A. Finn ◽  
Kent N. Bachus ◽  
Darrel S. Brodke ◽  
...  

Object Thoracolumbar corpectomy is a procedure commonly required for the treatment of various pathologies involving the vertebral body. Although the biomechanical stability of anterior reconstruction with plating has been studied, the biomechanical contribution of posterior instrumentation to anterior constructs remains unknown. The purpose of this study was to evaluate biomechanical stability after anterior thoracolumbar corpectomy and reconstruction with varying posterior constructs by measuring bending stiffness for the axes of flexion/extension, lateral bending, and axial rotation. Methods Seven fresh human cadaveric thoracolumbar spine specimens were tested intact and after L-1 corpectomy and strut grafting with 4 different fixation techniques: anterior plating with bilateral, ipsilateral, contralateral, or no posterior pedicle screw fixation. Bending stiffness was measured under pure moments of ± 5 Nm in flexion/extension, lateral bending, and axial rotation, while maintaining an axial preload of 100 N with a follower load. Results for each configuration were normalized to the intact condition and were compared using ANOVA. Results Spinal constructs with anterior-posterior spinal reconstruction and bilateral posterior pedicle screws were significantly stiffer in flexion/extension than intact spines or spines with anterior plating alone. Anterior plating without pedicle screw fixation was no different from the intact spine in flexion/extension and lateral bending. All constructs had reduced stiffness in axial rotation compared with intact spines. Conclusions The addition of bilateral posterior instrumentation provided significantly greater stability at the thoracolumbar junction after total corpectomy than anterior plating and should be considered in cases in which anterior column reconstruction alone may be insufficient. In cases precluding bilateral posterior fixation, unilateral posterior instrumentation may provide some additional stability.


2006 ◽  
Vol 5 (4) ◽  
pp. 336-342 ◽  
Author(s):  
Roger Härtl ◽  
Robert H. Chamberlain ◽  
Mary S. Fifield ◽  
Dean Chou ◽  
Volker K. H. Sonntag ◽  
...  

Object Two new techniques for atlantoaxial fixation have been recently described. In one technique, C-2 intra-laminar screws are connected with C-1 lateral mass screws; in the second, C-1 and C-3 lateral mass screws are interconnected and C-2 is wired sublaminarly. Both techniques include a C1–2 interspinous graft. The authors compared these techniques with the gold-standard, interspinous graft–augmented C1–2 transarticular screw fixation and with a control C1–2 interspinous graft fixation procedure alone. Methods In six human cadaveric occiput–C4 specimens, nonconstraining 1.5-Nm pure moments were applied to induce flexion, extension, lateral bending, and axial rotation during which three-dimensional angular motion was measured optoelectronically. Each specimen was tested in the normal state, with graft alone (after odontoidectomy), and then in varying order after applying each construct with a rewired graft. All three constructs allowed significantly less angular motion at the C1–2 junction than the wired interspinous graft alone during lateral bending and axial rotation (p < 0.01, paired Student t-test) but not during flexion or extension. Transarticular screw fixation with an interspinous graft allowed less motion at the atlantoaxial junction than the two new constructs in several conditions. Differences were greater between the transarticular screw construct and the intralaminar screw construct than between the transarticular screw construct and the C1–3 lateral mass screw construct. During lateral bending and axial rotation, the C1–3 construct allowed less motion at the atlantoaxial junction than the intralaminar screw construct. Conclusions Biomechanically, the gold-standard C1–2 transarticular screw fixation outperformed the two new techniques during lateral bending and axial rotation. Wiring C-2 to C1–3 rods provided greater stability than C1–2 laminar screws, but it sacrificed C2–3 mobility. It is unknown whether the small differences observed biomechanically would lead to clinically relevant differences in fusion rates.


2008 ◽  
Vol 8 (2) ◽  
pp. 143-152 ◽  
Author(s):  
Nicholas C. Bambakidis ◽  
Iman Feiz-Erfan ◽  
Eric M. Horn ◽  
L. Fernando Gonzalez ◽  
Seungwon Baek ◽  
...  

Object The stability provided by 3 occipitoatlantal fixation techniques (occiput [Oc]–C1 transarticular screws, occipital keel screws rigidly interconnected with C-1 lateral mass screws, and suboccipital/sublaminar wired contoured rod) were compared. Methods Seven human cadaveric specimens received transarticular screws and 7 received occipital keel–C1 lateral mass screws. All specimens later underwent contoured rod fixation. All conditions were studied with and without placement of a structural graft wired between the skull base and C-1 lamina. Specimens were loaded quasistatically using pure moments to induce flexion, extension, lateral bending, and axial rotation while recording segmental motion optoelectronically. Flexibility was measured immediately postoperatively and after 10,000 cycles of fatigue. Results Application of Oc–C1 transarticular screws, with a wired graft, reduced the mean range of motion (ROM) to 3% of normal. Occipital keel–C1 lateral mass screws (also with graft) offered less stability than transarticular screws during extension and lateral bending (p < 0.02), reducing ROM to 17% of normal. The wired contoured rod reduced motion to 31% of normal, providing significantly less stability than either screw fixation technique. Fatigue increased motion in constructs fitted with transarticular screws, keel screws/lateral mass screw constructs, and contoured wired rods, by means of 19, 5, and 26%, respectively. In all constructs, adding a structural graft significantly improved stability, but the extent depended on the loading direction. Conclusions Assuming the presence of mild C1–2 instability, Oc–C1 transarticular screws and occipital keel–C1 lateral mass screws are approximately equivalent in performance for occipitoatlantal stabilization in promoting fusion. A posteriorly wired contoured rod is less likely to provide a good fusion environment because of less stabilizing potential and a greater likelihood of loosening with fatigue.


Author(s):  
Timothy L Lasswell ◽  
John B Medley ◽  
Jack P Callaghan ◽  
Duane S Cronin ◽  
Colin D McKinnon ◽  
...  

The aim of this experimental study was to assess the biomechanical performance of a novel C1 posterior arch (C1PA) clamp compared with C1 lateral mass (C1LM) screws in constructs used to treat atlantoaxial instability. These constructs had either C2 pedicle (C2P) screws or C2 translaminar (C2TL) screws. Eight fresh-frozen human cadaveric ligamentous spine specimens (C0-C3) were tested under six conditions: the intact state, the destabilized state after a simulated odontoid fracture, and when instrumented with four constructs (C1LM-C2P, C1LM-C2TL, C1PA-C2P, C1PA-C2TL). Each specimen was tested in a spinal loading simulator that separately applied axial rotation, flexion-extension and lateral bending. In each test condition, displacement controlled angular motion was applied in both directions at a speed of 2 deg/s until a resulting moment of 1.5 Nm was achieved. The measured ranges of motion (ROM) of the C1-C2 segments were compared for each test condition using nonparametric Friedman tests. The destabilized state had significantly more C1-C2 motion ( p < 0.05) than the intact state in all cases, and all constructs greatly reduced this motion. C2 pedicle screw constructs that used the C1PA clamp had significantly less C1-C2 motion ( p < 0.05) than those with C1LM screws in flexion-extension as well as axial rotation and no statistically significant difference was detected in lateral bending. C2 translaminar screw constructs that used the C1PA clamp had significantly less C1-C2 motion ( p < 0.05) than those with C1LM screws in flexion-extension and no statistically significant difference was detected in axial rotation or in lateral bending. Data from the current study suggested that constructs using the novel C1PA clamp would provide as good, or improved, biomechanical stability to the C1-C2 segment compared with constructs using C1LM screws.


2010 ◽  
Vol 13 (2) ◽  
pp. 253-259 ◽  
Author(s):  
Fatih Ersay Deniz ◽  
Leonardo B. C. Brasiliense ◽  
Bruno C. R. Lazaro ◽  
Phillip M. Reyes ◽  
Anna G. U. Sawa ◽  
...  

Object The authors investigated the biomechanical properties of transpedicular discectomy in the thoracic spine and compared the effects on spinal stability of a partial and total facetectomy. Methods Human thoracic specimens were tested while intact, after a transpedicular discectomy with partial facetectomy, and after an additional total facetectomy was incorporated. Nonconstraining pure moments were applied under load control (maximum 7.5 Nm) to induce flexion, extension, lateral bending, and axial rotation while spinal motion was measured at T8–9 optoelectronically. The range of motion (ROM) and lax zone were determined in each specimen and compared among conditions. Results Transpedicular discectomy with and without a total facetectomy significantly increased the ROM and lax zone in all directions of loading compared with the intact spine (p < 0.008). The segmental increase in ROM observed with the transpedicular discectomy was 25%. The additional total facetectomy created an insignificant 3% further increase in ROM compared with medial facetectomy (p > 0.2). Conclusions Transpedicular discectomy can be performed in the thoracic spine with a modest decrease in stability expected. Because the biomechanical behavior of a total facetectomy is equivalent to that of a medial facetectomy, the additional facet removal may be incorporated without further biomechanical consequences.