scholarly journals CT-to-fluoroscopy registration versus scan-and-plan registration for robot-assisted insertion of lumbar pedicle screws

2022 ◽  
Vol 52 (1) ◽  
pp. E8

OBJECTIVE Pedicle screw insertion for stabilization after lumbar fusion surgery is commonly performed by spine surgeons. With the advent of navigation technology, the accuracy of pedicle screw insertion has increased. Robotic guidance has revolutionized the placement of pedicle screws with 2 distinct radiographic registration methods, the scan-and-plan method and CT-to-fluoroscopy method. In this study, the authors aimed to compare the accuracy and safety of these methods. METHODS A retrospective chart review was conducted at 2 centers to obtain operative data for consecutive patients who underwent robot-assisted lumbar pedicle screw placement. The newest robotic platform (Mazor X Robotic System) was used in all cases. One center used the scan-and-plan registration method, and the other used CT-to-fluoroscopy for registration. Screw accuracy was determined by applying the Gertzbein-Robbins scale. Fluoroscopic exposure times were collected from radiology reports. RESULTS Overall, 268 patients underwent pedicle screw insertion, 126 patients with scan-and-plan registration and 142 with CT-to-fluoroscopy registration. In the scan-and-plan cohort, 450 screws were inserted across 266 spinal levels (mean 1.7 ± 1.1 screws/level), with 446 (99.1%) screws classified as Gertzbein-Robbins grade A (within the pedicle) and 4 (0.9%) as grade B (< 2-mm deviation). In the CT-to-fluoroscopy cohort, 574 screws were inserted across 280 lumbar spinal levels (mean 2.05 ± 1.7 screws/ level), with 563 (98.1%) grade A screws and 11 (1.9%) grade B (p = 0.17). The scan-and-plan cohort had nonsignificantly less fluoroscopic exposure per screw than the CT-to-fluoroscopy cohort (12 ± 13 seconds vs 11.1 ± 7 seconds, p = 0.3). CONCLUSIONS Both scan-and-plan registration and CT-to-fluoroscopy registration methods were safe, accurate, and had similar fluoroscopy time exposure overall.

2019 ◽  
Vol 18 (5) ◽  
pp. E171-E171
Author(s):  
Justice O Agyei ◽  
Asham Khan ◽  
Patrick K Jowdy ◽  
Timothy E O’Connor ◽  
Joshua E Meyers ◽  
...  

Abstract Robot-assisted pedicle screw insertion has been slowly gaining popularity in the spine surgery community. In previous studies, robotics has been shown to increase accuracy and reduce complication rates compared to other navigation technologies, although those studies have been conducted using traditional trajectories for pedicle screw insertion. We present a surgical video in which a robotics system (Mazor X; Mazor Robotics Ltd, Caesarea, Israel) was used to create cortical bone trajectories for the insertion of the screws. The patient in this case is a 52-yr-old woman with severe L4-5 disc herniation requiring a transforaminal interbody fusion with the insertion of pedicle screws. The robotic system's scan-and-plan technique was utilized, in which an intraoperative computed tomography (CT) scan generates a real-time operative plan. Other techniques for inserting pedicle screws using cortical bone trajectories include CT navigation and fluoroscopic guidance. These techniques allow the surgeon to manually direct the screw under precise guidance in multiple planes, although the surgeon is still using all 6 degrees of freedom the human hand provides. With robotic guidance, a pilot hole is drilled, which eliminates 4 of 6 degrees of freedom, which can potentially reduce the risk of misplaced screws. To our knowledge, this is the first video demonstrating pedicle screw insertion through cortical bone trajectories using robotic guidance. Future studies are warranted to compare cortical bone trajectory insertion using different navigation techniques to determine the long-term efficacy of each technique. The patient gave informed consent for surgery and video recording. Institutional review board approval was deemed unnecessary.


2019 ◽  
Vol 31 (1) ◽  
pp. 139-146 ◽  
Author(s):  
Camilo A. Molina ◽  
Nicholas Theodore ◽  
A. Karim Ahmed ◽  
Erick M. Westbroek ◽  
Yigal Mirovsky ◽  
...  

OBJECTIVEAugmented reality (AR) is a novel technology that has the potential to increase the technical feasibility, accuracy, and safety of conventional manual and robotic computer-navigated pedicle insertion methods. Visual data are directly projected to the operator’s retina and overlaid onto the surgical field, thereby removing the requirement to shift attention to a remote display. The objective of this study was to assess the comparative accuracy of AR-assisted pedicle screw insertion in comparison to conventional pedicle screw insertion methods.METHODSFive cadaveric male torsos were instrumented bilaterally from T6 to L5 for a total of 120 inserted pedicle screws. Postprocedural CT scans were obtained, and screw insertion accuracy was graded by 2 independent neuroradiologists using both the Gertzbein scale (GS) and a combination of that scale and the Heary classification, referred to in this paper as the Heary-Gertzbein scale (HGS). Non-inferiority analysis was performed, comparing the accuracy to freehand, manual computer-navigated, and robotics-assisted computer-navigated insertion accuracy rates reported in the literature. User experience analysis was conducted via a user experience questionnaire filled out by operators after the procedures.RESULTSThe overall screw placement accuracy achieved with the AR system was 96.7% based on the HGS and 94.6% based on the GS. Insertion accuracy was non-inferior to accuracy reported for manual computer-navigated pedicle insertion based on both the GS and the HGS scores. When compared to accuracy reported for robotics-assisted computer-navigated insertion, accuracy achieved with the AR system was found to be non-inferior when assessed with the GS, but superior when assessed with the HGS. Last, accuracy results achieved with the AR system were found to be superior to results obtained with freehand insertion based on both the HGS and the GS scores. Accuracy results were not found to be inferior in any comparison. User experience analysis yielded “excellent” usability classification.CONCLUSIONSAR-assisted pedicle screw insertion is a technically feasible and accurate insertion method.


2021 ◽  
Author(s):  
Vishal Kumar ◽  
Vishnu Baburaj ◽  
Prasoon Kumar ◽  
Sarvdeep Singh Dhatt

AbstractBackgroundPedicle screw insertion is routinely carried out in spine surgery that has traditionally been performed under fluoroscopy guidance. Robotic guidance has recently gained popularity in order to improve the accuracy of screw placement. However, it is unclear whether the use of robotics alters the accuracy of screw placement or clinical outcomes.ObjectivesThis systematic review aims to compare the results of pedicle screws inserted under fluoroscopy guidance, with those inserted under robotic guidance, in terms of both short-term radiographic outcomes, as well as long-term clinical outcomes.MethodsThis systematic review will be conducted according to the PRISMA guidelines. A literature search will be conducted on the electronic databases of PubMed, Embase, Scopus, and Ovid with a pre-determined search strategy. A manual bibliography search of included studies will also be done. Original articles in English that directly compare pedicle screw insertion under robotic guidance to those inserted under fluoroscopy guidance will be included. Data on outcomes will be extracted from included studies and analysis carried out with the help of appropriate software.


2010 ◽  
Vol 13 (4) ◽  
pp. 509-515 ◽  
Author(s):  
Cary Idler ◽  
Kevin W. Rolfe ◽  
Josef E. Gorek

Object This study was conducted to assess the in vivo safety and accuracy of percutaneous lumbar pedicle screw placement using the owl's-eye view of the pedicle axis and a new guidance technology system that facilitates orientation of the C-arm into the appropriate fluoroscopic view and the pedicle cannulation tool in the corresponding trajectory. Methods A total of 326 percutaneous pedicle screws were placed from L-3 to S-1 in 85 consecutive adult patients. Placement was performed using simple coaxial imaging of the pedicle with the owl's-eye fluoroscopic view. NeuroVision, a new guidance system using accelerometer technology, helped align the C-arm trajectory into the owl's-eye view and the cannulation tool in the same trajectory. Postoperative fine-cut CT scans were acquired to assess screw position. Medical records were reviewed for complications. Results Five of 326 screws breached a pedicle cortex—all breaches were less than 2 mm—for an accuracy rate of 98.47%. Five screws violated an adjacent facet joint. All were at the S-1 superior facet and included in a fusion. No screw violated an adjacent mobile facet or disc space. There were no cases of new or worsening neurological symptoms or deficits for an overall clinical accuracy of 100%. Conclusions The owl's-eye technique of coaxial pedicle imaging with the C-arm fluoroscopy, facilitated by NeuroVision, is a safe and accurate means by which to place percutaneous pedicle screws for degenerative conditions of the lumbar spine. This is the largest series reported to use the oblique or owl's-eye projection for percutaneous pedicle screw insertion. The accuracy of percutaneous screw insertion with this technique meets or exceeds that of other reported clinical series or techniques.


2013 ◽  
Vol 26 (6) ◽  
pp. E248-E253 ◽  
Author(s):  
Keitaro Matsukawa ◽  
Yoshiyuki Yato ◽  
Osamu Nemoto ◽  
Hideaki Imabayashi ◽  
Takashi Asazuma ◽  
...  

Author(s):  
Laura E. Buckenmeyer ◽  
Kristophe J. Karami ◽  
Ata M. Kiapour ◽  
Vijay K. Goel ◽  
Constantine K. Demetropoulos ◽  
...  

Osteoporosis is a critical challenge in orthopedic surgery. Osteoporotic patients have an increased risk of loosening and failure of implant constructs due to a weaker bone-implant interface than with healthy bone. Pullout strength of pedicle screws is enhanced by increased screw insertion depth. However, more knowledge is needed to define optimal pedicle screw insertion depth in relation to screw-bone interface biomechanics and the resulting loosening risk. This study evaluates the effects of screw length on loosening risk in the osteoporotic lumbar spine.


2017 ◽  
Vol 42 (5) ◽  
pp. E14 ◽  
Author(s):  
Granit Molliqaj ◽  
Bawarjan Schatlo ◽  
Awad Alaid ◽  
Volodymyr Solomiichuk ◽  
Veit Rohde ◽  
...  

OBJECTIVEThe quest to improve the safety and accuracy and decrease the invasiveness of pedicle screw placement in spine surgery has led to a markedly increased interest in robotic technology. The SpineAssist from Mazor is one of the most widely distributed robotic systems. The aim of this study was to compare the accuracy of robot-guided and conventional freehand fluoroscopy-guided pedicle screw placement in thoracolumbar surgery.METHODSThis study is a retrospective series of 169 patients (83 women [49%]) who underwent placement of pedicle screw instrumentation from 2007 to 2015 in 2 reference centers. Pathological entities included degenerative disorders, tumors, and traumatic cases. In the robot-assisted cohort (98 patients, 439 screws), pedicle screws were inserted with robotic assistance. In the freehand fluoroscopy-guided cohort (71 patients, 441 screws), screws were inserted using anatomical landmarks and lateral fluoroscopic guidance. Patients treated before 2009 were included in the fluoroscopy cohort, whereas those treated since mid-2009 (when the robot was acquired) were included in the robot cohort. Since then, the decision to operate using robotic assistance or conventional freehand technique has been based on surgeon preference and logistics. The accuracy of screw placement was assessed based on the Gertzbein-Robbins scale by a neuroradiologist blinded to treatment group. The radiological slice with the largest visible deviation from the pedicle was chosen for grading. A pedicle breach of 2 mm or less was deemed acceptable (Grades A and B) while deviations greater than 2 mm (Grades C, D, and E) were classified as misplacements.RESULTSIn the robot-assisted cohort, a perfect trajectory (Grade A) was observed for 366 screws (83.4%). The remaining screws were Grades B (n = 44 [10%]), C (n = 15 [3.4%]), D (n = 8 [1.8%]), and E (n = 6 [1.4%]). In the fluoroscopy-guided group, a completely intrapedicular course graded as A was found in 76% (n = 335). The remaining screws were Grades B (n = 57 [12.9%]), C (n = 29 [6.6%]), D (n = 12 [2.7%]), and E (n = 8 [1.8%]). The proportion of non-misplaced screws (corresponding to Gertzbein-Robbins Grades A and B) was higher in the robot-assisted group (93.4%) than the freehand fluoroscopy group (88.9%) (p = 0.005).CONCLUSIONSThe authors’ retrospective case review found that robot-guided pedicle screw placement is a safe, useful, and potentially more accurate alternative to the conventional freehand technique for the placement of thoracolumbar spinal instrumentation.


2020 ◽  
Vol 33 (6) ◽  
pp. 806-811
Author(s):  
Inge J. M. H. Caelers ◽  
Kim Rijkers ◽  
Sander M. J. van Kuijk ◽  
Henk van Santbrink ◽  
Rob A. de Bie ◽  
...  

OBJECTIVEThe risk of novel postoperative neurological events due to pedicle screw malpositioning in lumbar fusion surgery is minimized by using one of the several image-guided techniques for pedicle screw insertion. These techniques for guided screw insertion range from intraoperative fluoroscopy to intraoperative navigation. A practical technique consists of anatomical identification of the screw entry point followed by lateral fluoroscopy used for guidance during insertion of the screw. This technique is available in most clinics and is less expensive than intraoperative navigation. However, the safety of lateral fluoroscopy–guided pedicle screw placement with regard to novel postoperative neurological events due to screw malposition has been addressed only rarely in the literature. In this study the authors aimed to determine the rate of novel postoperative neurological events due to intraoperative and postoperatively established screw malpositioning during lateral fluoroscopy–assisted screw insertion.METHODSIncluded patients underwent lateral fluoroscopy–assisted lumbosacral screw insertion between January 2012 and August 2017. The occurrence of novel postoperative neurological events was analyzed from patient files. In case of an event, surgical reports were screened for the occurrence of intraoperative screw malposition. Furthermore, postoperative CT scans were analyzed to identify and describe possible screw malposition.RESULTSIn total, 246 patients with 1079 screws were included. Novel postoperative neurological events were present in 36 patients (14.6%). In 8 of these 36 patients (3.25% of the total study population), the neurological events could be directly attributed to screw malposition. Screw malpositioning was caused either by problematic screw insertion with immediate screw correction (4 patients) or by malpositioned screws for which the malposition was established postoperatively using CT scans (4 patients). Three patients with screw malposition underwent revision surgery without subsequent symptom relief.CONCLUSIONSLateral fluoroscopy–assisted lumbosacral screw placement results in low rates of novel postoperative neurological events caused by screw malposition. In the majority of patients suffering from novel postoperative neurological events, these events could not be attributed to screw malpositioning, but rather were due to postoperative neurapraxia of peripheral nerves, neuropathy, or intraoperative traction of nerve roots.


2015 ◽  
Vol 36 (11) ◽  
pp. 1161
Author(s):  
Xiao ZHAI ◽  
Zi-qiang CHEN ◽  
Ming-yuan YANG ◽  
Ying-chuan ZHAO ◽  
Hai-jian NI ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document