fluoroscopy guidance
Recently Published Documents


TOTAL DOCUMENTS

94
(FIVE YEARS 37)

H-INDEX

11
(FIVE YEARS 1)

2022 ◽  
pp. rapm-2021-103183
Author(s):  
Guy Feigin ◽  
Ning Nan Wang ◽  
Vitaliano Di Grazia ◽  
Philip Peng

IntroductionCoccydynia is a multifactorial complex clinical challenge. A multimodal approach with both conservative measures and procedural interventions is often recommended. We described a novel approach of radiofrequency (RF) ablation for the management of coccydynia.MethodsThree patients with known history of coccydynia refractory to conservative therapy were referred to our clinic. All received different types of RF ablation before: one with anterior bipolar lesion with no analgesia benefit, one with posterior stripped lesion with good benefit but only after 8 weeks of pain flare and one received anterior monopolar lesion with 50% pain reduction for 2–3 months. All subjects underwent a novel RF ablation to the anterior surface of the sacrococcygeal and intercoccygeal joints with two bipolar lesions using multi-tined needles under fluoroscopy guidance. One bipolar lesion was between two needles: one in the sacrococcygeal and another in the intercoccygeal (between first and second coccyx) joints. Another bipolar lesion was between needles on both side of the sacrococcygeal joint.ResultsAll experienced at least 65% pain relief for 6 months. The sitting endurance increased from less than 5 min to an average of 70 min. No adverse effect was observed in two and in the patient who used to have pain flare after lesioning, the pain flare lasted only for 2 weeks.DiscussionThe configuration of the two bipolar lesions with multi-tined needles in this case series stimulates the thinking of new approach for the ablation technique for pain from coccyx. Further prospective large case cohort study is needed.


2021 ◽  
Author(s):  
Vishal Kumar ◽  
Vishnu Baburaj ◽  
Prasoon Kumar ◽  
Sarvdeep Singh Dhatt

AbstractBackgroundPedicle screw insertion is routinely carried out in spine surgery that has traditionally been performed under fluoroscopy guidance. Robotic guidance has recently gained popularity in order to improve the accuracy of screw placement. However, it is unclear whether the use of robotics alters the accuracy of screw placement or clinical outcomes.ObjectivesThis systematic review aims to compare the results of pedicle screws inserted under fluoroscopy guidance, with those inserted under robotic guidance, in terms of both short-term radiographic outcomes, as well as long-term clinical outcomes.MethodsThis systematic review will be conducted according to the PRISMA guidelines. A literature search will be conducted on the electronic databases of PubMed, Embase, Scopus, and Ovid with a pre-determined search strategy. A manual bibliography search of included studies will also be done. Original articles in English that directly compare pedicle screw insertion under robotic guidance to those inserted under fluoroscopy guidance will be included. Data on outcomes will be extracted from included studies and analysis carried out with the help of appropriate software.


2021 ◽  
Vol 2021 (3) ◽  
Author(s):  
Harris Kristanto ◽  
Ardian Rizal ◽  
Setyasih Anjarwani ◽  
Yoga Waranugraha

The temporary pacemaker (TPM) insertion must be done in symptomatic bradycardia to provide adequate heart rate and stable hemodynamic. Transvenous TPM is inserted under fluoroscopy guidance. However, in an extraordinary situation, such as the unavailability of the catheterization laboratory, transvenous TPM insertion can be performed using the blind approach. This case report focused on the procedural aspects of blind transvenous TPM insertion using femoral vein access when fluoroscopy is unavailable. By performing the blind transvenous TPM insertion, the patient should be stabilized as soon as possible. The confirmation of the lead placement using fluoroscopy was needed to ensure that the tip of the electrode was in the proper position.


2021 ◽  
Vol 11 ◽  
pp. 39
Author(s):  
Tyler John Richards ◽  
James Eric Schmitt ◽  
Leo J. Wolansky ◽  
Ameya P. Nayate

Objectives: Lumbar punctures performed in radiology departments have significantly increased over the last few decades and are typically performed in academic centers by radiology trainees using fluoroscopy guidance. Performing fluoroscopy-guided lumbar punctures (FGLPs) can often constitute a large portion of a trainee’s workday and the impact of performing FGLPs on the trainee’s clinical productivity (i.e. dictating reports on neuroradiology cross-sectional imaging) has not been studied. The purpose of the study was to evaluate the relationship between the number of FGLPs performed and cross-sectional neuroimaging studies dictated by residents during their neuroradiology rotation (NR). Material and Methods: The number of FGLPs and myelograms performed and neuroimaging studies dictated by radiology residents on our neuroradiology service from July 2008 to December 2017 were retrospectively reviewed. The relationship between the number of FGLPs performed and neuroimaging studies (CT and MRI) dictated per day by residents was examined. Results: Radiology residents (n = 84) performed 3437 FGLPs and myelograms and interpreted 33402 cross-sectional studies. Poisson regression demonstrated an exponential decrease in number of studies dictated daily with a rising number of FGLPs performed (P = 0.0001) and the following formula was derived: Number of expected studies dictated per day assuming no FGLPs × e-0.25 x number of FGLPs = adjusted expected studies dictated for the day. Conclusion: We quantified the impact performing FGLPs can have on the number of neuroimaging reports residents dictate on the NR. We described solutions to potentially decrease unnecessary FGLP referrals including establishing departmental guidelines for FGLP referrals and encouraging bedside lumbar punctures attempts before referral. We also emphasized equally distributing the FGLPs among trainees to mitigate procedural burden.


Animals ◽  
2021 ◽  
Vol 11 (6) ◽  
pp. 1838
Author(s):  
Alessandro Spadari ◽  
Giulia Forni ◽  
Sara Del Magno ◽  
Claudio Tagliavia ◽  
Marco Canova ◽  
...  

The aims of the present study were to compare the percentages of articular cartilage removed using a lateral drilling approach of the proximal interphalangeal joint (PIPJ) and a dorsal drilling approach, and to assess the usefulness of digital fluoroscopy when performing a lateral drilling approach. Sixty cadaveric PIPJs were drilled using a surgical drill bit to remove the articular cartilage. The limbs were divided into three groups containing 10 forelimbs and 10 hindlimbs each. One group received the dorsal drilling approach, the second one received the lateral drilling approach and the last one received the lateral drilling approach under digital fluoroscopy guidance. The percentage of articular cartilage removed from each articular surface was assessed using Adobe Photoshop ® software. The percentages of removed cartilage turned out to be significantly higher with lateral approach, especially under fluoroscopic guidance, both in the forelimbs (p = 0.00712) and hindlimbs (p = 0.00962). In conclusion, the lateral drilling approach seems to be a minimally invasive technique with which to perform PIPJ arthrodesis, even more efficient than the previously reported dorsal approach.


2021 ◽  
Author(s):  
Nicolas Amoretti ◽  
Danoob Dalili ◽  
Diego Palominos ◽  
Francois Cornelis ◽  
Nicolas Theumann ◽  
...  

2020 ◽  
pp. 112972982097626
Author(s):  
Tarik Hanane ◽  
James Lane ◽  
Eduardo Mireles-Cabodevila ◽  
Anita J Reddy ◽  
Jonathan J Taliercio ◽  
...  

COVID-19 patients admitted to the ICU have high incidence of AKI requiring prolonged renal replacement therapy and often necessitate the placement of a tunneled dialysis catheter (TDC). We describe our experience with two cases of COVID-19 patients who underwent successful bedside placement of TDC under ultrasound guidance using anatomical landmarks without fluoroscopy guidance. Tunneled dialysis catheter placement under direct fluoroscopy remains the standard of care; but in well selected patients, placement of tunneled dialysis catheter at the bedside using anatomic landmarks without fluoroscopy can be safely and successfully performed without compromising the quality of care and avoid transfer of COVID-19 infected patients outside the ICU.


Sign in / Sign up

Export Citation Format

Share Document