Biomechanical testing of anterior and posterior thoracolumbar instrumentation in the cadaveric spine

2004 ◽  
Vol 1 (1) ◽  
pp. 116-121 ◽  
Author(s):  
Kurt M. Eichholz ◽  
Patrick W. Hitchon ◽  
Aaron From ◽  
Paige Rubenbauer ◽  
Satoshi Nakamura ◽  
...  

Object. Thoracolumbar burst fractures frequently require surgical intervention. Although the use of either anterior or posterior instrumentation has advantages and disadvantages, there have been few studies in which these two approaches have been compared biomechanically. Methods. Ten human cadaveric spines were subjected to subtotal L-3 corpectomy. In five spines placement of L-3 wooden strut grafts with lateral L2–4 dual rod and screw instrumentation was performed. Five other spines underwent L1–5 pedicle screw fixation. The spines were fatigued between steps of the experiment. The spines were load tested with pure moments of 1.5, 3, 4.5, and 6 Nm in the intact state and after placement of instrumentation in six degrees of freedom (flexion, extension, right and left lateral bending, and right and left axial rotation). In axial rotation posterior instrumentation significantly increased spinal rigidity compared with that of the intact state, whereas anterior instrumentation did not. Combined anterior—posterior instrumentation did not significantly increase the rigidity of the spine when compared with anterior or posterior instrumentation alone. Posterior instrumentation alone provided a greater reduction in angular rotation compared with anterior instrumentation alone in all degrees of freedom; however, statistical significance was achieved only in extension at 6 Nm. Conclusions. The increased rigidity provided by pedicle screw instrumentation compared with the intact state or with anterior instrumentation is due to the longer construct spanning five levels and the three-column engagement of the pedicle screws. The decision to use anterior or posterior instrumentation should be based on the clinical necessity of canal decompression and correction of angulation.

2000 ◽  
Vol 93 (1) ◽  
pp. 102-108 ◽  
Author(s):  
Patrick W. Hitchon ◽  
Vijay Goel ◽  
Thomas Rogge ◽  
Andrew Dooris ◽  
John Drake ◽  
...  

Object. The authors conducted a study to determine if the rigidity supplied to the spine by posterior placement of the Ray threaded fusion cage (TFC) is further enhanced by the placement of pedicle screws and, additionally, if bilateral anteriorly placed TFCs render the spine more rigid than a single anteriorly placed TFC. Methods. Ten human cadaveric spinal specimens (L2—S1) were affixed within a testing frame. Loads of 1.5, 3, 4.5, and 6 Nm were applied to the spine in six degrees of freedom: flexion—extension, right and left lateral bending, and right and left axial rotation. Motion in an x, y, and z cartesian axis system was tracked using dual video cameras following light-emitting diodes attached to the spine and base plate. Load testing of the spines was performed in the intact mode, following which the spinal segments were randomized to receive anterior or posterior instrumentation. In five spine specimens we performed posterior discectomy, posterior lumbar interbody fusion (PLIF) with placment of femoral rings and pedicle screws, PLIF with bilateral TFCs, and bilateral TFCs with pedicle screws. Five other spines underwent anterior-approach discectomy, followed by implantation of a unilateral cage and bilateral cages. Load testing was performed after each step. Conclusion. Spines in which PLIF with pedicle screws and TFCs with pedicle screws were placed were more rigid than after discectomy in all directions of motion except flexion. Anterior discectomy provided significantly (p ≤ 0.05) less stability in left and right axial rotation than the intact spines and following posterior discectomy. Following anterior implantation of bilateral TFCs, spines were significantly more rigid than after discectomy in all directions except extension.


2005 ◽  
Vol 2 (3) ◽  
pp. 339-343 ◽  
Author(s):  
Patrick W. Hitchon ◽  
Kurt Eichholz ◽  
Christopher Barry ◽  
Paige Rubenbauer ◽  
Aditya Ingalhalikar ◽  
...  

Object. The authors compared the biomechanical performance of the human cadaveric spine implanted with a metallic ball-and-cup artificial disc at L4–5 with the spine's intact state and after anterior discectomy. Methods. Seven human L2—S1 cadaveric spines were mounted on a biomechanical testing frame. Pure moments of 0, 1.5, 3.0, 4.5, and 6.0 Nm were applied to the spine at L-2 in six degrees of motion (flexion, extension, right and left lateral bending, and right and left axial rotation). The spines were tested in the intact state as well as after anterior L4–5 discectomy. The Maverick disc was implanted in the discectomy defect, and load testing was repeated. The artificial disc created greater rigidity for the spine than was present after discectomy, and the spine performed biomechanically in a manner comparable with the intact state. Conclusions. The results indicate that in an in vitro setting, this model of artificial disc stabilizes the spine after discectomy, restoring motion comparable with that of the intact state.


2001 ◽  
Vol 95 (2) ◽  
pp. 208-214 ◽  
Author(s):  
Hans-Joachim Wilke ◽  
Sinead Kavanagh ◽  
Sylvia Neller ◽  
Christian Haid ◽  
Lutz Eberhart Claes

Object. Current procedures for treatment of degenerative disc disease may not restore flexibility or disc height to the intervertebral disc. Recently, a prosthetic device, intended to replace the degenerated nucleus pulposus, was developed. In this biomechanical in vitro test the authors study the effect of implanting a prosthetic nucleus in cadaveric lumbar intervertebral discs postnucleotomy and determine if the flexibility and disc height of the L4–5 motion segment is restored. Methods. The prosthetic disc nucleus device consists of two hydrogel pellets, each enclosed in a woven polyethylene jacket. Six human cadaveric lumbar motion segments (obtained in individuals who, at the time of death, were a mean age of 56.7 years) were loaded with moments of ± 7.5 Nm in flexion—extension, lateral bending, and axial rotation. The following states were investigated: intact, postnucleotomy, and after device implantation. Range of motion (ROM) and neutral zone (NZ) measurements were determined. Change in disc height from the intact state was measured after nucleotomy and device implantation, with and without a 200-N preload. Conclusions. Compared with the intact state (100%), the nucleotomy increased the ROM in flexion—extension to 118%, lateral bending to 112%, and axial rotation to 121%; once the device was implanted the ROM was reduced to 102%, 88%, and 90%, respectively. The NZ increased the ROM to 210%, lateral bending to 173%, and axial rotation to 107% after nucleotomy, and 146%, 149%, 44%, respectively, after device implantation. A 200-N preload reduced the intact and postnucleotomy disc heights by approximately 1 mm and 2 mm, respectively. The original intact disc height was restored after implantation of the device. The results of the cadaveric L4–5 flexibility testing indicate that the device can potentially restore ROM, NZ, and disc height to the denucleated segment.


2014 ◽  
Vol 21 (4) ◽  
pp. 577-581 ◽  
Author(s):  
Stephanus V. Viljoen ◽  
Nicole A. DeVries Watson ◽  
Nicole M. Grosland ◽  
James Torner ◽  
Brian Dalm ◽  
...  

Object The objective of this study was to evaluate the biomechanical properties of lateral instrumentation compared with short- and long-segment pedicle screw constructs following an L-1 corpectomy and reconstruction with an expandable cage. Methods Eight human cadaveric T10–L4 spines underwent an L-1 corpectomy followed by placement of an expandable cage. The spines then underwent placement of lateral instrumentation consisting of 4 monoaxial screws and 2 rods with 2 cross-connectors, short-segment pedicle screw fixation involving 1 level above and below the corpectomy, and long-segment pedicle screw fixation (2 levels above and below). The order of instrumentation was randomized in the 8 specimens. Testing was conducted for each fixation technique. The spines were tested with a pure moment of 6 Nm in all 6 degrees of freedom (flexion, extension, right and left lateral bending, and right and left axial rotation). Results In flexion, extension, and left/right lateral bending, posterior long-segment instrumentation had significantly less motion compared with the intact state. Additionally, posterior long-segment instrumentation was significantly more rigid than short-segment and lateral instrumentation in flexion, extension, and left/right lateral bending. In axial rotation, the posterior long-segment construct as well as lateral instrumentation were not significantly more rigid than the intact state. The posterior long-segment construct was the most rigid in all 6 degrees of freedom. Conclusions In the setting of highly unstable fractures requiring anterior reconstruction, and involving all 3 columns, long-segment posterior pedicle screw constructs are the most rigid.


2000 ◽  
Vol 92 (1) ◽  
pp. 87-92 ◽  
Author(s):  
Annette Kettler ◽  
Hans-Joachim Wilke ◽  
Rupert Dietl ◽  
Matthias Krammer ◽  
Christianto Lumenta ◽  
...  

Object. The function of interbody fusion cages is to stabilize spinal segments primarily by distracting them as well as by allowing bone ingrowth and fusion. An important condition for efficient formation of bone tissue is achieving adequate spinal stability. However, the initial stability may be reduced due to repeated movements of the spine during everyday activity. Therefore, in addition to immediate stability, stability after cyclic loading is of remarkable relevance; however, this has not yet been investigated. The object of this study was to investigate the immediate stabilizing effect of three different posterior lumbar interbody fusion cages and to clarify the effect of cyclic loading on the stabilization. Methods. Before and directly after implantation of a Zientek, Stryker, or Ray posterior lumbar interbody fusion cage, 24 lumbar spine segment specimens were each evaluated in a spine tester. Pure lateral bending, flexion—extension, and axial rotation moments (± 7.5 Nm) were applied continuously. The motion in each specimen was measured simultaneously. The specimens were then loaded cyclically (40,000 cycles, 5 Hz) with an axial compression force ranging from 200 to 1000 N. Finally, they were tested once again in the spine tester. Conclusions. In general, a decrease of movement in all loading directions was noted after insertion of the Zientek and Ray cages and an increase of movement after implantation of a Stryker cage. In all three cage groups greater stability was demonstrated in lateral bending and flexion than in extension and axial rotation. Reduced stability during cyclic loading was observed in all three cage groups; however, loss of stability was most pronounced when the Ray cage was used.


1999 ◽  
Vol 90 (1) ◽  
pp. 91-98 ◽  
Author(s):  
A. Giancarlo Vishteh ◽  
Neil R. Crawford ◽  
M. Stephen Melton ◽  
Robert F. Spetzler ◽  
Volker K. H. Sonntag ◽  
...  

Object. The authors sought to determine the biomechanics of the occipitoatlantal (occiput [Oc]—C1) and atlantoaxial (C1–2) motion segments after unilateral gradient condylectomy. Methods. Six human cadaveric specimens (skull with attached upper cervical spine) underwent nondestructive biomechanical testing (physiological loads) during flexion—extension, lateral bending, and axial rotation. Axial translation from tension to compression was also studied across Oc—C2. Each specimen served as its own control and underwent baseline testing in the intact state. The specimens were then tested after progressive unilateral condylectomy (25% resection until completion), which was performed using frameless stereotactic guidance. At Oc—C1 for all motions that were tested, mobility increased significantly compared to baseline after a 50% condylectomy. Flexion—extension, lateral bending, and axial rotation increased 15.3%, 40.8%, and 28.1%, respectively. At C1–2, hypermobility during flexion—extension occurred after a 25% condylectomy, during axial rotation after 75% condylectomy, and during lateral bending after a 100% condylectomy. Conclusions. Resection of 50% or more of the occipital condyle produces statistically significant hypermobility at Oc—C1. After a 75% resection, the biomechanics of the Oc—C1 and C1–2 motion segments change considerably. Performing fusion of the craniovertebral junction should therefore be considered if half or more of one occipital condyle is resected.


2000 ◽  
Vol 93 (1) ◽  
pp. 109-116
Author(s):  
Albert V. B. Brasil ◽  
Danilo G. Coelho ◽  
Tarcísio Eloy P. B. Filho ◽  
Fernando M. Braga

Object. The authors conducted a biomechanical study in which they compared the uses of the Rogers interspinous and the Lovely-Carl tension band wiring techniques for internal fixation of the cervical spine. Method. An extensive biomechanical evaluation (stiffness in positive and negative rotations around the x, y, and z axes; range of motion in flexion—extension, bilateral axial rotation, and bilateral bending; and neutral zone in flexion—extension, bilateral axial rotation, and lateral bending to the right and to the left) was performed in two groups of intact calf cervical spines. After these initial tests, all specimens were subjected to a distractive flexion Stage 3 ligamentous lesion. Group 1 specimens then underwent surgical fixation by the Rogers technique, and Group 2 specimens underwent surgery by using the Lovely—Carl technique. After fixation, specimens were again submitted to the same biomechanical evaluation. The percentage increase or decrease between the pre- and postoperative parameters was calculated. These values were considered quantitative indicators of the efficacy of the techniques, and the efficacy of the two techniques was compared. Conclusions. Analysis of the findings demonstrated that in the spines treated with the Lovely—Carl technique less restriction of movement was produced without affecting stiffness, compared with those treated with the Rogers technique, thus making the Lovely—Carl technique clinically less useful.


2005 ◽  
Vol 3 (6) ◽  
pp. 465-470 ◽  
Author(s):  
Christopher P. Ames ◽  
Frank L. Acosta ◽  
Robert H. Chamberlain ◽  
Adolfo Espinoza Larios ◽  
Neil R. Crawford

Object. The authors present a biomechanical analysis of a newly designed bioabsorbable anterior cervical plate (ACP) for the treatment of one-level cervical degenerative disc disease. They studied anterior cervical discectomy and fusion (ACDF) in a human cadaveric model, comparing the stability of the cervical spine after placement of the bioabsorbable fusion plate, a bioabsorbable mesh, and a more traditional metallic ACP. Methods. Seven human cadaveric specimens underwent a C6–7 fibular graft—assisted ACDF placement. A one-level resorbable ACP was then placed and secured with bioabsorbable screws. Flexibility testing was performed on both intact and instrumented specimens using a servohydraulic system to create flexion—extension, lateral bending, and axial rotation motions. After data analysis, three parameters were calculated: angular range of motion, lax zone, and stiff zone. The results were compared with those obtained in a previous study of a resorbable fusion mesh and with those acquired using metallic fusion ACPs. For all parameters studied, the resorbable plate consistently conferred greater stability than the resorbable mesh. Moreover, it offered comparable stability with that of metallic fusion ACPs. Conclusions. Bioabsorbable plates provide better stability than resorbable mesh. Although the results of this study do not necessarily indicate that a resorbable plate confers equivalent stability to a metal plate, the resorbable ACP certainly yielded better results than the resorbable mesh. Bioabsorbable fusion ACPs should therefore be considered as alternatives to metal plates when a graft containment device is required.


1996 ◽  
Vol 84 (4) ◽  
pp. 552-558 ◽  
Author(s):  
Jens R. Chapman ◽  
Paul A. Anderson ◽  
Christopher Pepin ◽  
Sean Toomey ◽  
David W. Newell ◽  
...  

✓ Fractures, tumors, and other causes of instability at the cervicothoracic junction pose diagnostic and treatment challenges. The authors report on 23 patients with instability of the cervicothoracic region, which was treated with posterior plate fixation and fusion between the lower cervical and upper thoracic spine. During operation AO reconstruction plates with 8- or 12-mm hole spacing were affixed to the spine using screws in the cervical lateral masses and the thoracic pedicles. Postoperative immobilization consisted of the patient's wearing a simple external brace for 2 months. The following parameters were analyzed during the pre- and postoperative treatment period: neurological status, spine anatomy and reconstruction, and complications. Follow up consisted of clinical and radiographic examinations (mean duration of follow up, 15.4 months; range, 6–41 months). No neurovascular or pulmonary complications arose from surgery. All patients achieved a solid arthrodesis based on flexion-extension radiographs. There was no significant change in angulation during the postoperative period, but one patient had an increase in translation that was not clinically significant. There were no hardware complications that required reoperation. One patient requested hardware removal in hopes of reducing postoperative pain in the cervicothoracic region. One postoperative wound infection required debridement but not hardware removal. The authors conclude that posterior plate fixation is a satisfactory method of treatment of cervicothoracic instability.


2010 ◽  
Vol 13 (2) ◽  
pp. 234-239 ◽  
Author(s):  
Frank S. Bishop ◽  
Mical M. Samuelson ◽  
Michael A. Finn ◽  
Kent N. Bachus ◽  
Darrel S. Brodke ◽  
...  

Object Thoracolumbar corpectomy is a procedure commonly required for the treatment of various pathologies involving the vertebral body. Although the biomechanical stability of anterior reconstruction with plating has been studied, the biomechanical contribution of posterior instrumentation to anterior constructs remains unknown. The purpose of this study was to evaluate biomechanical stability after anterior thoracolumbar corpectomy and reconstruction with varying posterior constructs by measuring bending stiffness for the axes of flexion/extension, lateral bending, and axial rotation. Methods Seven fresh human cadaveric thoracolumbar spine specimens were tested intact and after L-1 corpectomy and strut grafting with 4 different fixation techniques: anterior plating with bilateral, ipsilateral, contralateral, or no posterior pedicle screw fixation. Bending stiffness was measured under pure moments of ± 5 Nm in flexion/extension, lateral bending, and axial rotation, while maintaining an axial preload of 100 N with a follower load. Results for each configuration were normalized to the intact condition and were compared using ANOVA. Results Spinal constructs with anterior-posterior spinal reconstruction and bilateral posterior pedicle screws were significantly stiffer in flexion/extension than intact spines or spines with anterior plating alone. Anterior plating without pedicle screw fixation was no different from the intact spine in flexion/extension and lateral bending. All constructs had reduced stiffness in axial rotation compared with intact spines. Conclusions The addition of bilateral posterior instrumentation provided significantly greater stability at the thoracolumbar junction after total corpectomy than anterior plating and should be considered in cases in which anterior column reconstruction alone may be insufficient. In cases precluding bilateral posterior fixation, unilateral posterior instrumentation may provide some additional stability.


Sign in / Sign up