Effect of a prosthetic disc nucleus on the mobility and disc height of the L4–5 intervertebral disc postnucleotomy

2001 ◽  
Vol 95 (2) ◽  
pp. 208-214 ◽  
Author(s):  
Hans-Joachim Wilke ◽  
Sinead Kavanagh ◽  
Sylvia Neller ◽  
Christian Haid ◽  
Lutz Eberhart Claes

Object. Current procedures for treatment of degenerative disc disease may not restore flexibility or disc height to the intervertebral disc. Recently, a prosthetic device, intended to replace the degenerated nucleus pulposus, was developed. In this biomechanical in vitro test the authors study the effect of implanting a prosthetic nucleus in cadaveric lumbar intervertebral discs postnucleotomy and determine if the flexibility and disc height of the L4–5 motion segment is restored. Methods. The prosthetic disc nucleus device consists of two hydrogel pellets, each enclosed in a woven polyethylene jacket. Six human cadaveric lumbar motion segments (obtained in individuals who, at the time of death, were a mean age of 56.7 years) were loaded with moments of ± 7.5 Nm in flexion—extension, lateral bending, and axial rotation. The following states were investigated: intact, postnucleotomy, and after device implantation. Range of motion (ROM) and neutral zone (NZ) measurements were determined. Change in disc height from the intact state was measured after nucleotomy and device implantation, with and without a 200-N preload. Conclusions. Compared with the intact state (100%), the nucleotomy increased the ROM in flexion—extension to 118%, lateral bending to 112%, and axial rotation to 121%; once the device was implanted the ROM was reduced to 102%, 88%, and 90%, respectively. The NZ increased the ROM to 210%, lateral bending to 173%, and axial rotation to 107% after nucleotomy, and 146%, 149%, 44%, respectively, after device implantation. A 200-N preload reduced the intact and postnucleotomy disc heights by approximately 1 mm and 2 mm, respectively. The original intact disc height was restored after implantation of the device. The results of the cadaveric L4–5 flexibility testing indicate that the device can potentially restore ROM, NZ, and disc height to the denucleated segment.

2005 ◽  
Vol 2 (3) ◽  
pp. 339-343 ◽  
Author(s):  
Patrick W. Hitchon ◽  
Kurt Eichholz ◽  
Christopher Barry ◽  
Paige Rubenbauer ◽  
Aditya Ingalhalikar ◽  
...  

Object. The authors compared the biomechanical performance of the human cadaveric spine implanted with a metallic ball-and-cup artificial disc at L4–5 with the spine's intact state and after anterior discectomy. Methods. Seven human L2—S1 cadaveric spines were mounted on a biomechanical testing frame. Pure moments of 0, 1.5, 3.0, 4.5, and 6.0 Nm were applied to the spine at L-2 in six degrees of motion (flexion, extension, right and left lateral bending, and right and left axial rotation). The spines were tested in the intact state as well as after anterior L4–5 discectomy. The Maverick disc was implanted in the discectomy defect, and load testing was repeated. The artificial disc created greater rigidity for the spine than was present after discectomy, and the spine performed biomechanically in a manner comparable with the intact state. Conclusions. The results indicate that in an in vitro setting, this model of artificial disc stabilizes the spine after discectomy, restoring motion comparable with that of the intact state.


2000 ◽  
Vol 92 (1) ◽  
pp. 87-92 ◽  
Author(s):  
Annette Kettler ◽  
Hans-Joachim Wilke ◽  
Rupert Dietl ◽  
Matthias Krammer ◽  
Christianto Lumenta ◽  
...  

Object. The function of interbody fusion cages is to stabilize spinal segments primarily by distracting them as well as by allowing bone ingrowth and fusion. An important condition for efficient formation of bone tissue is achieving adequate spinal stability. However, the initial stability may be reduced due to repeated movements of the spine during everyday activity. Therefore, in addition to immediate stability, stability after cyclic loading is of remarkable relevance; however, this has not yet been investigated. The object of this study was to investigate the immediate stabilizing effect of three different posterior lumbar interbody fusion cages and to clarify the effect of cyclic loading on the stabilization. Methods. Before and directly after implantation of a Zientek, Stryker, or Ray posterior lumbar interbody fusion cage, 24 lumbar spine segment specimens were each evaluated in a spine tester. Pure lateral bending, flexion—extension, and axial rotation moments (± 7.5 Nm) were applied continuously. The motion in each specimen was measured simultaneously. The specimens were then loaded cyclically (40,000 cycles, 5 Hz) with an axial compression force ranging from 200 to 1000 N. Finally, they were tested once again in the spine tester. Conclusions. In general, a decrease of movement in all loading directions was noted after insertion of the Zientek and Ray cages and an increase of movement after implantation of a Stryker cage. In all three cage groups greater stability was demonstrated in lateral bending and flexion than in extension and axial rotation. Reduced stability during cyclic loading was observed in all three cage groups; however, loss of stability was most pronounced when the Ray cage was used.


1999 ◽  
Vol 90 (1) ◽  
pp. 91-98 ◽  
Author(s):  
A. Giancarlo Vishteh ◽  
Neil R. Crawford ◽  
M. Stephen Melton ◽  
Robert F. Spetzler ◽  
Volker K. H. Sonntag ◽  
...  

Object. The authors sought to determine the biomechanics of the occipitoatlantal (occiput [Oc]—C1) and atlantoaxial (C1–2) motion segments after unilateral gradient condylectomy. Methods. Six human cadaveric specimens (skull with attached upper cervical spine) underwent nondestructive biomechanical testing (physiological loads) during flexion—extension, lateral bending, and axial rotation. Axial translation from tension to compression was also studied across Oc—C2. Each specimen served as its own control and underwent baseline testing in the intact state. The specimens were then tested after progressive unilateral condylectomy (25% resection until completion), which was performed using frameless stereotactic guidance. At Oc—C1 for all motions that were tested, mobility increased significantly compared to baseline after a 50% condylectomy. Flexion—extension, lateral bending, and axial rotation increased 15.3%, 40.8%, and 28.1%, respectively. At C1–2, hypermobility during flexion—extension occurred after a 25% condylectomy, during axial rotation after 75% condylectomy, and during lateral bending after a 100% condylectomy. Conclusions. Resection of 50% or more of the occipital condyle produces statistically significant hypermobility at Oc—C1. After a 75% resection, the biomechanics of the Oc—C1 and C1–2 motion segments change considerably. Performing fusion of the craniovertebral junction should therefore be considered if half or more of one occipital condyle is resected.


2004 ◽  
Vol 1 (1) ◽  
pp. 116-121 ◽  
Author(s):  
Kurt M. Eichholz ◽  
Patrick W. Hitchon ◽  
Aaron From ◽  
Paige Rubenbauer ◽  
Satoshi Nakamura ◽  
...  

Object. Thoracolumbar burst fractures frequently require surgical intervention. Although the use of either anterior or posterior instrumentation has advantages and disadvantages, there have been few studies in which these two approaches have been compared biomechanically. Methods. Ten human cadaveric spines were subjected to subtotal L-3 corpectomy. In five spines placement of L-3 wooden strut grafts with lateral L2–4 dual rod and screw instrumentation was performed. Five other spines underwent L1–5 pedicle screw fixation. The spines were fatigued between steps of the experiment. The spines were load tested with pure moments of 1.5, 3, 4.5, and 6 Nm in the intact state and after placement of instrumentation in six degrees of freedom (flexion, extension, right and left lateral bending, and right and left axial rotation). In axial rotation posterior instrumentation significantly increased spinal rigidity compared with that of the intact state, whereas anterior instrumentation did not. Combined anterior—posterior instrumentation did not significantly increase the rigidity of the spine when compared with anterior or posterior instrumentation alone. Posterior instrumentation alone provided a greater reduction in angular rotation compared with anterior instrumentation alone in all degrees of freedom; however, statistical significance was achieved only in extension at 6 Nm. Conclusions. The increased rigidity provided by pedicle screw instrumentation compared with the intact state or with anterior instrumentation is due to the longer construct spanning five levels and the three-column engagement of the pedicle screws. The decision to use anterior or posterior instrumentation should be based on the clinical necessity of canal decompression and correction of angulation.


2001 ◽  
Vol 95 (2) ◽  
pp. 215-220 ◽  
Author(s):  
Patrick W. Hitchon ◽  
Vijay Goel ◽  
John Drake ◽  
Derek Taggard ◽  
Matthew Brenton ◽  
...  

Object. Polymethylmethacrylate (PMMA) has long been used in the stabilization and reconstruction of traumatic and pathological fractures of the spine. Recently, hydroxyapatite (HA), an osteoconductive, biocompatible cement, has been used as an alternative to PMMA. In this study the authors compare the stabilizing effects of the HA product, BoneSource, with PMMA in an experimental compression fracture of L-1. Methods. Twenty T9—L3 cadaveric spine specimens were mounted individually on a testing frame. Light-emitting diodes were placed on the neural arches as well as the base. Motion was tracked by two video cameras in response to applied loads of 0 to 6 Nm. The weight-drop technique was used to induce a reproducible compression fracture of T-11 after partially coring out the vertebra. Load testing was performed on the intact spine, postfracture, after unilateral transpedicular vertebroplasty with 7 to 10 ml of PMMA or HA, and after flexion—extension fatiguing to 5000 cycles at ± 3 Nm. No significant difference between the HA- and PMMA cemented—fixated spines was demonstrated in flexion, extension, left lateral bending, or right and left axial rotation. The only difference between the two cements was encountered before and after fatiguing in right lateral bending (p ≤ 0.05). Conclusions. The results of this study suggest that the same angular rigidity can be achieved using either HA or PMMA. This is of particular interest because HA is osteoconductive, undergoes remodeling, and is not exothermic.


2003 ◽  
Vol 99 (2) ◽  
pp. 214-220 ◽  
Author(s):  
Paul W. Detwiler ◽  
Christina B. Spetzler ◽  
Sara B. Taylor ◽  
Neil R. Crawford ◽  
Randall W. Porter ◽  
...  

Object. The authors compared differences in biomechanical stability between two decompressive laminectomy techniques for treating lumbar stenosis. A Christmas tree laminectomy (CTL), in which bilateral facetectomies and foraminotomies are performed, was compared with facet-sparing laminectomy (FSL), in which the facets are undercut but not resected. Spinal instability was assessed immediately postoperatively and again after discectomy to model long-term degeneration. Methods. Sixteen motion segments obtained from five human cadaveric lumbar specimens were studied in vitro by conducting nondestructive flexibility tests. Specimens were tested intact, after FSL or CTL, and again after discectomy. Nonconstraining torques (≤ 5 Nm) were applied to induce flexion, extension, axial rotation, and lateral bending; strings and pulleys were used while vertebral angles were measured. Anteroposterior translation in response to shear loading (≤ 100 N) was also measured. Angular motion, shear motion, and sagittal-plane axes of rotation were compared to evaluate stability. Compared with the intact condition, CTL-treated specimens had significantly larger increases in angular motion during flexion, lateral bending, and axial rotation than their FSL-treated counterparts (p < 0.05, nonpaired Student t-tests). Subsequent discectomy caused greater increases in motion in the CTL group. Axes of rotation shifted less from their normal positions after FSL than after CTL. Conclusions. This study provides objective evidence that the treatment of lumbar stenosis with FSL induces less biomechanical instability and alters kinematics less than FSL. These findings support the use of the FSL in treating lumbar stenosis.


Author(s):  
Héctor E Jaramillo S

The annulus fibrosus has substantial variations in its geometrical properties (among individuals and between levels), and plays an important role in the biomechanics of the spine. Few works have studied the influence of the geometrical properties including annulus area, anterior / posterior disc height, and over the range of motion, but in general these properties have not been reported in the finite element models. This paper presents a probabilistic finite element analyses (Abaqus 6.14.2) intended to assess the effects of the average disc height ( hp) and the area ( A) of the annulus fibrosus on the biomechanics of the lumbar spine. The annulus model was loaded under flexion, extension, lateral bending, and axial rotation and analyzed for different combinations of hpand A in order to obtain their effects over the range of motion. A set of 50 combinations of hp(mean = 18.1 mm, SD = 3.5 mm) and A (mean = 49.8%, SD = 4.6%) were determined randomly according to a normal distribution. A Yeoh energy function was used for the matrix and an exponential function for the fibers. The range of motion was more sensitive to hpthan to A. With regard to the range of motion the segment was more sensitive in the following order: flexion, axial rotation, extension, and lateral bending. An increase of the hpproduces an increase of the range of motion, but this decreases when A increases. Comparing the range of motion with the experimental data, on average, 56.0% and 73.0% of the total of data were within the experimental range for the L4–L5 and L5–S1 segments, respectively. Further, an analytic equation was derived to obtain the range of motion as a function of the hpand A. This equation can be used to calibrate a finite element model of the spine segment, and also to understand the influence of each geometrical parameter on the range of motion.


2004 ◽  
Vol 100 (3) ◽  
pp. 277-283 ◽  
Author(s):  
Sung-Min Kim ◽  
T. Jesse Lim ◽  
Josemaria Paterno ◽  
Tae-Jin Hwang ◽  
Kun-Woo Lee ◽  
...  

Object. The authors compared the biomechanical stability of two anterior fixation procedures—anterior C1–2 Harms plate/screw (AHPS) fixation and the anterior C1–2 transarticular screw (ATS) fixation; and two posterior fixation procedures—the posterior C-1 lateral mass combined with C-2 pedicle screw/rod (PLM/APSR) fixation and the posterior C1–2 transarticular screw (PTS) fixation after destabilization. Methods. Sixteen human cervical spine specimens (Oc—C3) were tested in three-dimensional flexion—extension, axial rotation, and lateral bending motions after destabilization by using an atlantoaxial C1–2 instability model. In each loading mode, moments were applied to a maximum of 1.5 Nm, and the range of motion (ROM), neutral zone (NZ), and elastic zone (EZ) were determined and values compared using the intact spine, the destabilized spine, and the postfixation spine. The AHPS method produced inferior biomechanical results in flexion—extension and lateral bending modes compared with the intact spine. The lateral bending NZ and ROM for this method differed significantly from the other three fixation techniques (p < 0.05), although statistically significant differences were not obtained for all other values of ROM and NZ for the other three procedures. The remaining three methods restored biomechanical stability and improved it over that of the intact spine. Conclusions. The PLM/APSR fixation method was found to have the highest biomechanical stiffness followed by PTS, ATS, and AHPS fixation. The PLM/APSR fixation and AATS methods can be considered good procedures for stabilizing the atlantoaxial joints, although specific fixation methods are determined by the proper clinical and radiological characteristics in each patient.


2004 ◽  
Vol 100 (4) ◽  
pp. 337-342 ◽  
Author(s):  
Yoshihisa Kotani ◽  
Kuniyoshi Abumi ◽  
Yasuo Shikinami ◽  
Masahiko Takahata ◽  
Ken Kadoya ◽  
...  

Object. This 2-year experimental study was conducted to investigate the efficacy of a bioactive three-dimensional (3D) fabric disc for lumbar intervertebral disc replacement. The authors used a bioresorbable spinal fixation rod consisting of a forged composite of particulate unsintered hydroxyapatite/poly-l-lactide acid (HA/PLLA) for stability augmentation. The biomechanical and histological alterations as well as possible device-related loosening were examined at 2 years postoperatively. Methods. Two lumbar intervertebral discs (L2–3 and L4–5) were replaced with the 3D fabric discs, which were augmented by two titanium screws and a spanning bioresorbable rod (HA/PLLA). The segmental biomechanics and interface bone ingrowth were investigated at 6, 15, and 24 months postoperatively, and results were compared with the other two surgical groups (3D fabric disc alone; 3D fabric disc with additional anterior instrumentation stabilization). The 3D fabric disc and HA/PLLA—spinal segments demonstrated segmental mobility at 15 and 24 months; however, the range of motion (ROM) in flexion—extension decreased to 49 and 40%, respectively, despite statistically equivalent preserved torsional ROM. Histologically there was excellent osseous fusion at the 3D fabric disc surface—vertebral body interface. At 2 years posttreatment, no adverse tissue reaction nor aseptic loosening of the device was observed. Conclusions. Intervertebral disc replacement with the 3D fabric disc was viable and when used in conjunction with the bioresorbable HA/PLLA spinal augmentation. Further refinements of device design to create a stand-alone type are necessary to obviate the need for additional spinal stabilization.


2003 ◽  
Vol 98 (2) ◽  
pp. 202-209 ◽  
Author(s):  
L. Fernando Gonzalez ◽  
Neil R. Crawford ◽  
Robert H. Chamberlain ◽  
Luis E. Perez Garza ◽  
Mark C. Preul ◽  
...  

Object. The authors compared the biomechanical stability resulting from the use of a new technique for occipitoatlantal motion segment fixation with an established method and assessed the additional stability provided by combining the two techniques. Methods. Specimens were loaded using nonconstraining pure moments while recording the three-dimensional angular movement at occiput (Oc)—C1 and C1–2. Specimens were tested intact and after destabilization and fixation as follows: 1) Oc—C1 transarticular screws plus C1–2 transarticular screws; 2) occipitocervical transarticular (OCTA) plate in which C1–2 transarticular screws attach to a loop from Oc to C-2; and (3) OCTA plate plus Oc—C1 transarticular screws. Occipitoatlantal transarticular screws reduced motion to well within the normal range. The OCTA loop and transarticular screws allowed a very small neutral zone, elastic zone, and range of motion during lateral bending and axial rotation. The transarticular screws, however, were less effective than the OCTA loop in resisting flexion and extension. Conclusions. Biomechanically, Oc—C1 transarticular screws performed well enough to be considered as an alternative for Oc—C1 fixation, especially when instability at C1–2 is minimal. Techniques for augmenting these screws posteriorly by using a wired bone graft buttress, as is currently undertaken with C1–2 transarticular screws, may be needed for optimal performance.