Optimized management and control of household energy demand supplied from solar and traditional electrical and gas energy sources

2010 ◽  
Vol 43 (8) ◽  
pp. 280-285
Author(s):  
Michal Pawlowski ◽  
Mietek A. Brdyś
Afrika Focus ◽  
2018 ◽  
Vol 31 (1) ◽  
pp. 173-186 ◽  
Author(s):  
Felichesmi S. Lyakurwa ◽  
Eliaza Mkuna

Recently, energy access and efficiency have attracted much research interest due to their critical role in addressing the challenges of climate change and the country’s social and economic development. The major question in this study is whether household energy demand can be influenced by government institutions and political systems which switch their preferences towards clean energy sources including renewable energy. The analysis revealed that government agencies are not well-coordinated when dealing with energy access and efficiency issues e.g., ward and village leaders are not always in agreement and lack common understanding of issues arising out of increasing energy supply and use of energy efficient appliances. In addition, households witnessed that despite their low level of income, they would have done better in terms of accessing quality and affordable energy had they been educated or informed about the need to shift from using wood to electricity for different social and economic activities. The study recommends that universities offer training, research and consultancy in the energy field to help raise awareness among communities of costs and benefits of using clean energy sources. The results therefore, provide useful and current information to policy making and energy planning institutions on the barriers to energy access and efficiency in order to help formulate remedial action.


2021 ◽  
Vol 8 (1) ◽  
Author(s):  
Martin Pullinger ◽  
Jonathan Kilgour ◽  
Nigel Goddard ◽  
Niklas Berliner ◽  
Lynda Webb ◽  
...  

AbstractThe IDEAL household energy dataset described here comprises electricity, gas and contextual data from 255 UK homes over a 23-month period ending in June 2018, with a mean participation duration of 286 days. Sensors gathered 1-second electricity data, pulse-level gas data, 12-second temperature, humidity and light data for each room, and 12-second temperature data from boiler pipes for central heating and hot water. 39 homes also included plug-level monitoring of selected electrical appliances, real-power measurement of mains electricity and key sub-circuits, and more detailed temperature monitoring of gas- and heat-using equipment, including radiators and taps. Survey data included occupant demographics, values, attitudes and self-reported energy awareness, household income, energy tariffs, and building, room and appliance characteristics. Linked secondary data comprises weather and level of urbanisation. The data is provided in comma-separated format with a custom-built API to facilitate usage, and has been cleaned and documented. The data has a wide range of applications, including investigating energy demand patterns and drivers, modelling building performance, and undertaking Non-Intrusive Load Monitoring research.


2021 ◽  
pp. 0309524X2110241
Author(s):  
Nindra Sekhar ◽  
Natarajan Kumaresan

To overcome the difficulties of extending the main power grid to isolated locations, this paper proposes the local installation of a combination of three renewable energy sources, namely, a wind driven DFIG, a solar PV unit, a biogas driven squirrel-cage induction generator (SCIG), and an energy storage battery system. In this configuration one bi-directional SPWM inverter at the rotor side of the DFIG controls the voltage and frequency, to maintain them constant on its stator side, which feeds the load. The PV-battery also supplies the load, through another inverter and a hysteresis controller. Appropriately adding a capacitor bank and a DSTATCOM has also been considered, to share the reactive power requirement of the system. Performance of various modes of operation of this coordinated scheme has been studied through simulation. All the results and relevant waveforms are presented and discussed to validate the successful working of the proposed system.


Energies ◽  
2021 ◽  
Vol 14 (12) ◽  
pp. 3680
Author(s):  
Lasantha Meegahapola ◽  
Siqi Bu

Power network operators are rapidly incorporating wind power generation into their power grids to meet the widely accepted carbon neutrality targets and facilitate the transition from conventional fossil-fuel energy sources to the clean and low-carbon renewable energy sources [...]


2015 ◽  
Vol 785 ◽  
pp. 576-580 ◽  
Author(s):  
Liaw Geok Pheng ◽  
Rosnani Affandi ◽  
Mohd Ruddin Ab Ghani ◽  
Chin Kim Gan ◽  
Jano Zanariah

Solar energy is one of the more attractive renewable energy sources that can be used as an input energy source for heat engines. In fact, any heat energy sources can be used with the Stirling engine. Stirling engines are mechanical devices working theoretically on the Stirling cycle, or its modifications, in which compressible fluids, such as air, hydrogen, helium, nitrogen or even vapors, are used as working fluids. When comparing with the internal combustion engine, the Stirling engine offers possibility for having high efficiency engine with less exhaust emissions. However, this paper analyzes the basic background of Stirling engine and reviews its existing literature pertaining to dynamic model and control system for parabolic dish-stirling (PD) system.


Author(s):  
Bisma Imtiaz ◽  
Imran Zafar ◽  
Cui Yuanhui

Due to the rapid increase in energy demand with depleting conventional sources, the world’s interest is moving towards renewable energy sources. Microgrid provides easy and reliable integration of distributed generation (DG) units based on renewable energy sources to the grid. The DG’s are usually integrated to microgrid through inverters. For a reliable operation of microgrid, it must have to operate in grid connected as well as isolated mode. Due to sudden mode change, performance of the DG inverter system will be compromised. Design and simulation of an optimized microgrid model in MATLAB/Simulink is presented in this work. The goal of the designed model is to integrate the inverter-interfaced DG’s to the microgrid in an efficient manner. The IEEE 13 bus test feeder has been converted to a microgrid by integration of DG’s including diesel engine generator, photovoltaic (PV) block and battery. The main feature of the designed MG model is its optimization in both operated modes to ensure the high reliability. For reliable interconnection of designed MG model to the power grid, a control scheme for DG inverter system based on PI controllers and DQ-PLL (phase-locked loop) has been designed. This designed scheme provides constant voltage in isolated mode and constant currents in grid connected mode. For power quality improvement, the regulation of harmonic current insertion has been performed using LCL filter. The performance of the designed MG model has been evaluated from the simulation results in MATLAB/ Simulink.


2021 ◽  
Vol 69 (2) ◽  
pp. 21-30
Author(s):  
Nasreddine ATTOU ◽  
Sid-Ahmed ZIDI ◽  
Mohamed KHATIR ◽  
Samir HADJERI

Energy management in grid-connected Micro-grids (MG) has undergone rapid evolution in recent times due to several factors such as environmental issues, increasing energy demand and the opening of the electricity market. The Energy Management System (EMS) allows the optimal scheduling of energy resources and energy storage systems in MG in order to maintain the balance between supply and demand at low cost. The aim is to minimize peaks and fluctuations in the load and production profile on the one hand, and, on the other hand, to make the most of renewable energy sources and energy exchanges with the utility grid. In this paper, our attention has been focused on a Rule-based energy management system (RB EMS) applied to a residential multi-source grid-connected MG. A Microgrid model has been implemented that combines distributed energy sources (PV, WT, BESS), a number of EVs equipped with the Vehicle to Grid technology (V2G) and variable load. Different operational scenarios were developed to see the behaviour of the implemented management system during the day, including the random demand profile of EV users, the variation in load and production, grid electricity price variation. The simulation results presented in this paper demonstrate the efficacy of the suggested EMS and confirm the strategy's feasibility as well as its ability to properly share power among different sources, loads and vehicles by obeying constraints on each element.


1990 ◽  
Vol 12 (4) ◽  
pp. 279-288 ◽  
Author(s):  
Kamal Rijal ◽  
N.K. Bansal ◽  
P.D. Grover

2015 ◽  
Vol 48 (8) ◽  
pp. 385-390 ◽  
Author(s):  
Chudong Tong ◽  
Nael H. El-Farra ◽  
Ahmet Palazoglu

1999 ◽  
Vol 42 (3) ◽  
pp. 281-294
Author(s):  
Y. Toukourou ◽  
K.-J. Peters

Abstract. Title of the paper: Impaet of feed restriction on the growth performance of goat kids The influence of differential feeding levels on growth performance in 72 goat kids "Bunte Deutsche Edelziege" during the pre-weaning period was examined. The 72 animals were assigned to a control group and two experimental groups that received respectively 20% and 40% less milk/less concentrate compared to the control (fed at 2.4 times energy demand for maintenance). The experimental gained animals significantly less relative to the control group. However, during the subsequent realimentation period when all animals were fed at a energy level of 2.4 times maintenance same treatment, the daily weight gain among the kids was in inverse proportion to the level ofmilk deprivation in the pre-weaning phase. The rapid growth among the experimental animals was such that the initial differences in body weight between the experimental and control groups were fully compensated. Growth performance of kids with respect to different levels of concentrated feed was less clear cut and d.ffered significantly only behveen the group that received the lowest feed level relative to all the other groups.


Sign in / Sign up

Export Citation Format

Share Document