scholarly journals The accuracy of modified risk malignancy index (RMI) in predicting malignancy of epithelial type ovarian cancer

Author(s):  
Esfi Triana ◽  
Defrin Dr. ◽  
Joserizal Serudji ◽  
Adriswan Dr.

Abstract Objective:To investigate the accuracy of modified Risk of Malignancy Index (RMI) in predicting malignancy of epithelial type ovarian tumour. Method: This research was comparative research using cross-sectional study design, which compared RMI modification and RMI method in predicting malignancy of epithelial type ovarian tumour. The sampling technique was consecutive sampling. This research was conducted on October 2017 until samples were fulfilled in Obstetrics and Gynecology Division of RSUP Dr. M. Djamil and Laboratory of RSUP Dr. M Djamil in Padang. Chi-square test was used to compare specificity, sensitivity, positive predictive value (PPV), negative predictive value (NPV), positive likelihood ratio (PLR), negative likelihood ratio (NLR, and accuracy of RMI modification and RMI with 95% CI (p≤0,05). Results: A total of 61 subjects were recruited in this study. Sensitivity, specificity, PPV, NPV, PLR, NLR, and accuracy RMI modification scoring was 90.5%, 82.5%, 73.1%, 94.3%, 5.1, 0.1, dan 85.2%. Sensitivity, specificity, PPV, NPV, PLR, NLR, and accuracy RMI scoring was 66.7%, 70%, 53.8%, 80%, 2.2, 0.4, and 70% Conclusions:Modified RMI scoring method was more accurate in predicting the malignancy of ovarian type epithelial tumours than RMI. Keywords: CA125, malignancy, ovarian tumor,pelvic mass, RMI,   Abstrak Tujuan: Mengetahui akurasi Risk of Malignancy Index (RMI) dalam prediksi keganasan tumor ovarium tipe epitel.  Metode: Penelitian ini merupakan penelitian komparatif dengan desain penelitian potong lintang yang membandingkan metode RMI modifikasi dan RMI dalam prediksi keganasan tumor ovarium tipe epitel. Jumlah sampel sebanyak 61 orang. Teknik pengambilan sampel berurutan. Penelitian di mulai pada bulan Oktober 2017 hingga jumlah sampel terpenuhi di Departemen Obstetri dan Ginekologi RSUP Dr. M Djamil dan Laboratorium RSUP Dr. M Djamil Padang. Untuk membandingkan spesifisitas, sensitivitas, nilai duga positif (NDP), nilai duga negatif (NDN), rasio kemungkinan positif (RKP), rasio kemungkinan negatif (RKN), dan akurasi RMI modifikasi dan RMI digunakan uji chi-square dengan 99% CI (p≤0,01). Hasil: Sensitivitas, spesifisitas, NDP, NDN, RKP, RKN, dan akurasi skoring RMI modifikasi adalah 90,5%, 82,5%, 73,1%, 94,3%, 5,1, 0,1, dan 85,2%. Sensitivitas, spesifisitas, NDP, NDN, RKP, RKN, dan akurasi skoring RMI adalah 66,7%, 70%, 53,8%, 80%, 2,2, 0,4, dan 70%. Kesimpulan: Metode skoring RMI modifikasi lebih akurat dalam memprediksi keganasan tumor ovarium tipe epitel dibandingkan RMI. Kata kunci: CA125, keganasan, massapelvik, RMI, tumor ovarium

Author(s):  
Amita Ray ◽  
Divya S. ◽  
B. N. Kumar Guru ◽  
A. S. Ramaswamy ◽  
Bharat Kumar

Background: Identification of the nature of an adnexal mass can ensure optimum management. Single parameters as well as diagnostic models using a combination of several parameters are in use. The International Ovarian Tumor Analysis (IOTA) consortium has developed and published the Assessment of Different NEoplasias in the adneXa (ADNEX) model, which differentiates between benign and malignant masses. Authors conducted this study with the aim of finding a cut off value for this model in the study population and comparing the diagnostic accuracy of this model to that of the risk of malignancy (RMI).Methods: Women with adnexal masses admitted to the 3 medical college affiliated hospitals for surgical management were included in this study. Appropriate investigations were done to calculate the RMI-I and ADNEX score for each participant. A cut off score for the ADNEX model was determined and diagnostic accuracy tests were done for comparison.Results: At a cut-off of 29 for the ADNEX model and 200 for RMI model the sensitivity was 75% and 77.8, specificity 100% and 80.6%; Positive Predictive Value (PPV) 100%and 60%; Negative Predictive Value (NPV) 91% and 90.6%; Positive Likelihood ratio of infinity and 4 and a negative Likelihood Ratio of 2.8 and 2.5 respectively.Conclusions: The ADNEX model rates higher than the RMI in almost all tests of diagnostic accuracy and can be used for triaging, framing a referral policy and prioritizing surgery.


Author(s):  
Richard Norris ◽  
Christian Kopkow ◽  
Michael James McNicholas

ObjectivesTo determine the accuracy of the dial test, used alone and in combination with additional clinical tests, in the diagnosis of an isolated posterolateral corner (PLC) injury, combined PLC-posterior cruciate ligament (PCL) injury or medial knee injury.MethodsA retrospective analysis of consecutive patients who underwent arthroscopic and/or open knee ligament reconstruction surgery was conducted. The dial test was performed in an outpatient’s clinic as part of a routine knee examination. Examination under anaesthetic and intraoperative findings were used as the reference standard test to determine the diagnostic accuracy of the dial test used alone and in combination with other PCL and medial knee tests. Sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV), positive likelihood ratio (LR+) and negative likelihood ratio (LR−) were calculated with corresponding 95% CI.ResultsData from 87 patients were available and included in the data analysis. For an isolated PLC injury, the dial test sensitivity and specificity were 0.20 (95% CI 0.08 to 0.39) and 1.00 (95% CI 0.92 to 1.00). The PPV and NPV were 1.00 (95% CI 0.52 to 1.00) and 0.70 (95% CI 0.59 to 0.80). LR+ and LR− of the dial test detecting isolated PLC injury were infinity (95% CI calculation not possible, infinity) and 0.80 (95% CI 0.41 to 1.57). The diagnostic accuracy of the dial test, when used alone and in combination with other PCL and medial knee tests, was also calculated for combined PLC-PCL and medial knee injuries.ConclusionA negative dial test at 30° of knee flexion can rule out a PLC injury, while a test that is positive at 30° and negative at 90° indicates a PLC injury, without concomitant injury to the PCL or medial knee ligaments. A positive test at both 30° and 90° can indicate isolated PLC, combined PLC-PCL or medial ligament injuries, and other knee examination findings are required to differentially diagnose these injury patterns.Level of evidenceII.


2015 ◽  
Vol 22 (5) ◽  
pp. 510-515 ◽  
Author(s):  
Linchuan Wang ◽  
Yan Yu ◽  
Wei Chen ◽  
Jin Feng ◽  
Jinyuan Wang ◽  
...  

ABSTRACTThe purpose of this study was to evaluate the characteristics of the T-SPOT.TB test for the diagnosis of active tuberculosis (ATB) and to distinguish ATB from other diseases using a receiver operating characteristic (ROC) curve. A total of 535 patients with suspected active tuberculosis were enrolled in the study and divided into ATB and nonactive tuberculosis (NATB) groups, as well as pulmonary tuberculosis (PTB) and extrapulmonary tuberculosis (EPTB) subgroups. The sensitivity, specificity, positive predictive value, negative predictive value, positive likelihood ratio, and negative likelihood ratio of the T-SPOT.TB test for the diagnosis of ATB were 84.95%, 85.12%, 82.94%, 86.93%, 5.71, and 0.18, respectively. The median number of spot-forming cells (SFCs) in the ATB group was higher than that in the NATB group (71 versus 1;P< 0.0001). The sensitivities in the PTB and EPTB subgroups were 92.31% and 81.77%. The areas under the curve (AUC) for the diagnosis of ATB using the T-SPOT.TB, early secreted antigenic target 6 (ESAT-6), and culture filtrate protein 10 (CFP-10) were 0.906, 0.884, and 0.877, respectively. A cutoff of 42.5 SFCs for ATB yielded a positive predictive value of 100%. Our study shows that the T-SPOT.TB test is useful for the diagnosis of ATB. Utilizing an ROC curve to select an appropriate cutoff made it possible to discriminate ATB from NATB.


2020 ◽  
Author(s):  
Paul Kearney ◽  
Robert Getts ◽  
Clive Hayward ◽  
David Luta ◽  
Alex Porter ◽  
...  

AbstractBackgroundMisdiagnosis of peanut allergy is a significant clinical challenge. Here, a novel diagnostic blood-based test using a Bead-Based Epitope Assay (“peanut BBEA”) has been developed on the LEAP cohort and then independently validated on the CoFAR2 and POISED cohorts.MethodsDevelopment of the peanut BBEA followed the National Academy of Medicine’s established guidelines with discovery performed on 133 subjects from the non-interventional arm of the LEAP trial and an independent validation performed on 81 subjects from the CoFAR2 study and 84 subjects from the POISED study. All subject samples were analyzed using the BBEA methodology. The peanut BBEA test measures levels of two Ara h 2 epitopes and compares their combination to a pre=specified threshold. If the combination of the two epitope levels is at or below the threshold, then the subject is ruled “Not Allergic”, otherwise the subject is ruled “Allergic”.All allergic diagnoses were OFC confirmed and subjects’ ages were 7-55 years.ResultsIn validation on the CoFAR2 and POISED cohorts, the peanut BBEA test had a combined sensitivity, specificity, positive predictive value, negative predictive value, positive likelihood ratio, negative likelihood ratio and accuracy of 91%, 95%, 95%, 91%, 18.2, 0.09 and 93%, respectively.ConclusionThe peanut BBEA test performance in validation demonstrated overall high accuracy and compared very favorably with existing diagnostic tests for peanut allergy including skin prick testing, peanut sIgE and peanut component testing.


2020 ◽  
Vol 7 (6) ◽  
pp. 1225
Author(s):  
Gokul Krishnan R. ◽  
Mangalabharathi S. ◽  
Mohammed Sajjid ◽  
Ramya S.

Background: Endtidalcarbonmonoxide (ETCOc) and Carboxyhemoglobin (COHB) levels correlate well to bilirubin production and an availability of non-invasive point of care (POC) device in predicting significant hyperbilirubinemia is of great advantage when compared to measurement of serum bilirubin. Objective of the study is to measure a value of ETCOc and COHB in the early neonatal period for the prediction of significant hyperbilirubinemia.Methods: This was the descriptive Cross Sectional Study. ETCOc and COHB were measured 12th hourly for 72 hours followed by TSB in whom the TCB was >14mg/dl. Neonates were classified as jaundiced whose TSB values were in phototherapy range as per AAP Recommendations. Receiver Operative Curves (ROC) were created by appropriate statistical software for ETCOc and COHb to predict significant hyperbilirubinemia. The Sensitivity, Specificity, Positive predictive value, Negative predictive value and likelihood ratios of each was determined and the correlation between ETCOc and COHb levels, ETCOc and TCB, COHB and TCB at different hours of age was evaluated.Results: Among the total 320 infants, 156 of them developed significant hyperbilirubinemia. The ETCOc and COHB level at 60 hours of age was the most predictive of significant hyperbilirubinemia by ROC analysis. ETCOc cut-off of 1.65 ppm at 60 hours of age has a sensitivity, specificity, positive predictive value, negative predictive value, positive likelihood ratio and negative likelihood ratio of 84.6%, 80.5%, 80.5% and 84.6%, 4.33 and 0.19. COHB cut-off of 1.32 ppm at 60 hours of age has a sensitivity, specificity, positive predictive value, negative predictive value, positive likelihood ratio and negative likelihood ratio of 84.6%, 81%, 80% and 84.2%, 4.34 and 0.19.ETCOc had a maximum correlation with COHB at 48 hours of age.Conclusions: An increased level of Endtidalcarbonmonoxide and Carboxyhemoglobin in the early neonatal period is useful as a screening test for prediction of significant hyperbilirubinemia.


2021 ◽  
Vol 20 ◽  
pp. 153303382110119
Author(s):  
Wen-Ting Zhang ◽  
Guo-Xun Zhang ◽  
Shuai-Shuai Gao

Background: Leukemia is a common malignant disease in the human blood system. Many researchers have proposed circulating microRNAs as biomarkers for the diagnosis of leukemia. We conducted a meta-analysis to evaluate the diagnostic accuracy of circulating miRNAs in the diagnosis of leukemia. Methods: A comprehensive literature search (updated to October 13, 2020) in PubMed, EMBASE, Web of Science, Cochrane Library, Wanfang database and China National Knowledge Infrastructure (CNKI) was performed to identify eligible studies. The sensitivity, specificity, positive likelihood ratio (PLR), negative likelihood ratio (NLR), diagnostic odds ratio (DOR), and area under the curve (AUC) for diagnosing leukemia were pooled for both overall and subgroup analysis. The meta-regression and subgroup analysis were performed to explore heterogeneity and Deeks’ funnel plot was used to assess publication bias. Results: 49 studies from 22 publications with a total of 3,489 leukemia patients and 2,756 healthy controls were included in this meta-analysis. The overall sensitivity, specificity, positive likelihood ratio, negative likelihood ratio, diagnostic odds ratio and area under the curve were 0.83, 0.92, 10.8, 0.18, 59 and 0.94, respectively. Subgroup analysis shows that the microRNA clusters of plasma type could carry out a better diagnostic accuracy of leukemia patients. In addition, publication bias was not found. Conclusions: Circulating microRNAs can be used as a promising noninvasive biomarker in the early diagnosis of leukemia.


2021 ◽  
Vol 49 (3) ◽  
pp. 030006052199296
Author(s):  
Juan Wang ◽  
Liu Yang ◽  
Yanjun Diao ◽  
Jiayun Liu ◽  
Jinjie Li ◽  
...  

Objective To evaluate the performance of a DNA methylation-based digital droplet polymerase chain reaction (ddPCR) assay to detect aberrant DNA methylation in cell-free DNA (cfDNA) and to determine its application in the detection of hepatocellular carcinoma (HCC). Methods The present study recruited patients with liver-related diseases and healthy control subjects. Blood samples were used for the extraction of cfDNA, which was then bisulfite converted and the extent of DNA methylation quantified using a ddPCR platform. Results A total of 97 patients with HCC, 80 healthy control subjects and 46 patients with chronic hepatitis B/C virus infection were enrolled in the study. The level of cfDNA in the HCC group was significantly higher than that in the healthy control group. For the detection of HCC, based on a cut-off value of 15.7% for the cfDNA methylation ratio, the sensitivity and specificity were 78.57% and 89.38%, respectively. The diagnostic accuracy was 85.27%, the positive predictive value was 81.91% and the negative predictive value was 87.20%. The positive likelihood ratio of 15.7% in HCC diagnosis was 7.40, while the negative likelihood ratio was 0.24. Conclusions A sensitive methylation-based assay might serve as a liquid biopsy test for diagnosing HCC.


2015 ◽  
Vol 9 (11-12) ◽  
pp. 387 ◽  
Author(s):  
Nathan C Wong ◽  
Rahul K Bansal ◽  
Armando J Lorenzo ◽  
Jorge DeMaria ◽  
Luis H Braga

<p><strong>Introduction:</strong> Although previous evidence has shown that ultrasound is unreliable to diagnose undescended testis, many primary care providers (PCP) continue to misuse it. We assessed the performance of ultrasound as a diagnostic tool for palpable undescended testis, as well as the diagnostic agreement between PCP and pediatric urologists.</p><p><strong>Methods:</strong> We performed a prospective observational cohort study between 2011 and 2013 for consecutive boys referred with a diagnosis of undescended testis to our tertiary pediatric hospital. Patients referred without an ultrasound and those with non-palpable testes were excluded. Data on referring diagnosis, pediatric urology examination and ultrasound reports were analyzed.</p><p><strong>Results:</strong> Our study consisted of 339 boys. Of these, patients without an ultrasound (n = 132) and those with non-palpable testes (n = 38) were excluded. In the end, there were 169 pateints in this study. Ultrasound was performed in 50% of referred boys showing 256 undescended testis. The mean age at time of referral was 45 months. When ultrasound was compared to physical examination by the pediatric urologist, agreement was only 34%. The performance of ultrasound for palpable undescended testis was: sensitivity = 100%; specificity = 16%; positive predictive value = 34%; negative predictive value = 100%; positive likelihood ratio = 1.2; and negative likelihood ratio = 0. Diagnosis of undescended testis by PCP was confirmed by physical examination in 30% of cases, with 70% re-diagnosed with normal or retractile testes.</p><p><strong>Conclusion:</strong> Ultrasound performed poorly to assess for palpable undescended testis in boys and should not be used. Although the study has important limitations, there is an increasing need for education and evidence-based guidelines for PCP in the management of undescended testis.</p>


2019 ◽  
Vol 39 (1) ◽  
Author(s):  
Zhanzhan Li ◽  
Yanyan Li ◽  
Jun Fu ◽  
Na Li ◽  
Liangfang Shen

AbstractWe conducted comprehensive analyses to assess the diagnostic ability of miRNA-451 in cancers. A systematic online search was conducted in PubMed, Web of Science, China’s national knowledge infrastructure, and VIP databases from inception to July 31, 2017. The bivariate random effect model was used for calculating sensitivity, specificity, positive likelihood ratio, negative likelihood ratio, diagnostic odds ratio, and area under cure (AUC). The whole pooled sensitivity and specificity were 0.85 (0.77–0.90) and 0.85 (0.78–0.90) with their 95% confidence interval (95%CI), respectively. The pooled AUC was 0.91 (95%CI: 0.89–0.94). Positive likelihood ratio was 5.57 (95%CI: 3.74–8.31), negative likelihood ratio was 0.18 (95%CI: 0.11–0.28), and diagnostic odds ratio was 31.33 (95%CI: 15.19–64.61). Among Asian population, the sensitivity and specificity were 0.85 (95%CI: 0.77–0.91) and 0.86 (95%CI: 0.78–0.91), respectively. The positive likelihood ratio and negative likelihood ratio were 5.87 (95%CI: 3.78–9.12) and 0.17 (95%CI: 0.11–0.28). The diagnostic odds ratio and AUC were 34.31 (15.51–75.91) and 0.92 (0.89–0.94). The pooled sensitivity, specificity, positive likelihood ratio, negative likelihood ratio, diagnostic odds ratio, and AUC for digestive system cancer were 0.83, 0.88, 6.87, 0.20, 35.13, and 0.92, respectively. The other cancers were 0.87, 0.81, 4.55, 0.16, 28.51, and 0.90, respectively. For sample source, the results still remain consistent. Our results indicated miRNA-451 has a moderate diagnostic ability for cancers, and could be a potential early screening biomarker, and considered as an adjuvant diagnostic index when being combined with other clinical examinations.


2015 ◽  
Vol 2015 ◽  
pp. 1-8 ◽  
Author(s):  
Na Sun ◽  
Jinhua Zhao ◽  
Wenli Qiao ◽  
Taisong Wang

Objective.We conducted a meta-analysis to evaluate the predictive value of interim18F-FDG PET/CT in patients with DLBCL treated with R-CHOP chemotherapy.Methods.We searched for articles published in PubMed, ScienceDirect, Wiley, Scopus, and Ovid database from inception to March 2014. Articles related to interim PET/CT in patients with DLBCL treated with R-CHOP chemotherapy were selected. PFS with or without OS was chosen as the endpoint to evaluate the prognostic significance of interim PET/CT.Results.Six studies with a total of 605 cases were included. The sensitivity of interim PET/CT ranged from 21.2% to 89.7%, and the pooled sensitivity was 52.4%. The specificity of interim PET/CT ranged from 37.4% to 90.7%, and the pooled specificity was 67.8%. The pooled positive likelihood ratio and negative likelihood ratio were 1.780 and 0.706, respectively. The explained AUC was 0.6978 and theQ*was 0.6519.Conclusions.The sensitivity and specificity of interim PET/CT in predicting the outcome of DLBCL patients treated with R-CHOP chemotherapy were not satisfactory (52.4% and 67.8%, resp.). To improve this, some more work should be done to unify the response criteria and some more research to assess the prognostic value of interim PET/CT with semiquantitative analysis.


Sign in / Sign up

Export Citation Format

Share Document