Considering the large energy consumption of conventional water heaters in residential buildings, the performance of a new type of water heater has been characterized through conducting experiments and numerical modelling. The specific water heater investigated in this work benefits from heat absorption from the indoor air, denoted as the air source heat pump water heater (ASHPWH), and is located in the Archetype Sustainable Twin House B in Toronto. The experiments have been conducted under three different indoor conditions associated with temperature and humidity. The coefficient of performance (COP), which quantifies the ratio of heating capacity to the consumed power of ASHPWH, ranges between 1.5 and 5, depending on the indoor dry bulb and water inlet temperatures. A TRNSYS model of ASHPWH has been constructed based on the obtained experimental results and has subsequently been integrated with a TRNSYS model of the Archetype Sustainable House (ASH). The numerical results were verified with the experimental data. The model results suggests that after employing ASHPWH, the domestic hot water energy consumption reduces by 60.3% and 53.2% compared to the electric water heater in summer and winter respectively. Due to the energy absorption of ASHPWH from the indoor environment, the heating load of the ASH house increases while its cooling load decreases. Furthermore, the annual electricity consumption of the ASH house due to the required heating and cooling as well as the domestic hot water demand is reduced by 21.3%. Finally, as a consequence of employing ASHPWH, the energy cost and GHG emission were reduced respectively by 22% and 21.7%. By investigating the system in four other Canadian cities, it appears that Vancouver and Edmonton would have the maximum and minimum energy savings respectively.

2021 ◽  
Author(s):  
Afarin Amirirad

Considering the large energy consumption of conventional water heaters in residential buildings, the performance of a new type of water heater has been characterized through conducting experiments and numerical modelling. The specific water heater investigated in this work benefits from heat absorption from the indoor air, denoted as the air source heat pump water heater (ASHPWH), and is located in the Archetype Sustainable Twin House B in Toronto. The experiments have been conducted under three different indoor conditions associated with temperature and humidity. The coefficient of performance (COP), which quantifies the ratio of heating capacity to the consumed power of ASHPWH, ranges between 1.5 and 5, depending on the indoor dry bulb and water inlet temperatures. A TRNSYS model of ASHPWH has been constructed based on the obtained experimental results and has subsequently been integrated with a TRNSYS model of the Archetype Sustainable House (ASH). The numerical results were verified with the experimental data. The model results suggests that after employing ASHPWH, the domestic hot water energy consumption reduces by 60.3% and 53.2% compared to the electric water heater in summer and winter respectively. Due to the energy absorption of ASHPWH from the indoor environment, the heating load of the ASH house increases while its cooling load decreases. Furthermore, the annual electricity consumption of the ASH house due to the required heating and cooling as well as the domestic hot water demand is reduced by 21.3%. Finally, as a consequence of employing ASHPWH, the energy cost and GHG emission were reduced respectively by 22% and 21.7%. By investigating the system in four other Canadian cities, it appears that Vancouver and Edmonton would have the maximum and minimum energy savings respectively.


2015 ◽  
Vol 797 ◽  
pp. 185-191
Author(s):  
Arkadiusz Gużda ◽  
Norbert Szmolke

The article compares two means for domestic hot water production (DHW) for a detached house that is using gas boiler with a closed combustion chamber and air source heat pump water heater (ASHPWH). An analysis of domestic hot water production using an air source heat pump was made taking into account coefficient of performance listed according to the new BS EN 16147 standard. The analysis of outlay related to the investment and operating costs was also performed. Ultimately, the more profitable choice for domestic hot water production was made.


2016 ◽  
Author(s):  
Gabriel Agila ◽  
Guillermo Soriano

This research develops a detailed model for a Water to Water Heat Pump Water Heater (HPWH), operating for heating and cooling simultaneously, using two water storage tanks as thermal deposits. The primary function of the system is to produce useful heat for domestic hot water services according to the thermal requirements for an average household (two adults and one child) in the city of Quito, Ecuador. The purpose of the project is to analyze the technical and economic feasibility of implementing thermal storage and heat pump technology to provide efficient thermal services and reduce energy consumption; as well as environmental impacts associated with conventional systems for residential water heating. An energy simulation using TRNSYS 17 is carried to evaluate model operation for one year. The purpose of the simulation is to assess and quantifies the performance, energy consumption and potential savings of integrating heat pump systems with thermal energy storage technology, as well as determines the main parameter affecting the efficiency of the system. Finally, a comparative analysis based on annual energy consumption for different ways to produce hot water is conducted. Five alternatives were examined: (1) electric storage water heater; (2) gas fired water heater; (3) solar water heater; (4) air source heat pump water heater; and (5) a heat pump water heater integrated with thermal storage.


Author(s):  
Yahya I. Sharaf-Eldeen ◽  
Craig V. Muccio ◽  
Eric Gay

This work involves measurements, analyses, and evaluations of the performance of add-on, Heat Pump Water Heater (HPWH) systems in residential and small commercial applications. Two air-source Heat Pump (HP) systems rated at 7,000- and 12,000-BTU (2.051- and 3.517-kWh), were utilized in this work. The two HPs were retrofitted to two 50-gallon (189.3 liters) electric-resistance storage water-heaters with their electric heating elements removed. A third, standard electric water-heater (EWH), was used for comparison. The testing set-up was fully instrumented for measurements of pertinent parameters, including inlet and outlet water temperatures, inlet and outlet air temperatures of the HPs, temperature and humidity of the air in the surrounding space, volume of water draws out of the storage heater tanks, as well as electric energy consumptions of the systems. Several performance measures were used in this work, including the Coefficient of Performance (COP), which is a measure of the instantaneous energy output in comparison with the energy input; Energy Factor (EF), which is an average measure of the COP taken over extended periods of time; and the First Hour Rating (FHR), which is a measure of the maximum volume of hot water that a storage type water-heater can supply to a residence within an hour. The results obtained clearly indicate that, HPWH systems are much more efficient as compared to standard EWHs. While the average value of the EF for a standard EWH is close to 1.0, the HPWH systems yield EFs averaging more than 2.00, resulting in annual energy savings averaging more than 50%. The results also showed that, HPWH systems are effective at reducing utility peak demand-loads, in addition to providing substantial cost savings to consumers.


2014 ◽  
Vol 521 ◽  
pp. 748-751
Author(s):  
Zhao Xia Zhou

A survey for water heater in urban residential buildings is carried in Wuhan. The results show that more than 40% subjects use solar energy water heat. More than 20% subjects point out the energy consumption of water heater should be decreased. There are about 24.8% subjects take initial cost as the first place when they chose water heater. 44.2% subjects know about heat pump water heater, but they could not buy it if the initial cost is too high. There are 84% subjects could select heat pump water heater when the cost is no more 20% high than the average price of the common water heaters. Moreover, the energy consumptions of residential water heaters are also investigated. The energy consumption characteristics of water heater in Wuhan are analyzed.


Author(s):  
H. I. Abu-Mulaweh

Heat pump water heater was designed and a prototype was developed and constructed. The performance of the heat pump water heater prototype is described by presenting some experimental test data. The experimental measurements include temperature, flow rates, and power consumption. The testing procedure consisted of evaluating the recovery rate and the coefficient of performance (COP) of the system. The results strongly indicate that heat pump water heater system design is very practical and it provides the consumer with a more efficient hot water heater alternative.


Author(s):  
Shuang Lu ◽  
Jingyi Wu

In Chinese market, many homes use heat pump systems for heating and cooling. Domestic hot water is usually provided by a domestic water heater making use of electricity, natural gas or solar energy, which is known for its great energy costs. These systems consume much energy and increase the total cost of the required domestic energy. A new system combining heat pump with water heater is proposed in this paper, and it is named domestic energy system. The system can realize the provision of space heating, cooling and domestic hot water throughout the year. Based on the different types of heat pumps and water heaters, domestic energy consumption patterns are divided into five categories: heat pump and gas-fired water heater system, heat pump and solar water heater system, heat pump and electricity water heater system, heat pump and heat pump water heater system, and domestic energy system. This study describes and compares all of the above-mentioned systems including energy and exergy analysis. Results showed that the domestic energy system can save energy and provide good economy.


2019 ◽  
Vol 9 (3) ◽  
pp. 310-318
Author(s):  
Fengguo Liu ◽  
Zhenxi Ma ◽  
Rui Zhang

Abstract Shower wastewater contains large amounts of heat, and recovering and utilizing shower wastewater heat energy to heat shower water is of great significance for energy saving. This paper proposed a gas engine heat pump water heater (GEHPWH) using shower wastewater as the heat source. Thermodynamic models were built to evaluate the performance of the GEHPWH and compare it with an electrical heat pump water heater (EHPWH). The results show that the GEHPWH has higher hot water outlet temperature and coefficient of performance (COP) than the EHPWH under the same conditions. Furthermore, the GEHPWH can maintain stable hot water outlet temperature and higher primary energy ratio (PER) in variable water flow mode, which resolves the issue that the conventional EHPWH needs an auxiliary heat source. Finally, based on a case, the GEHPWH reveals smaller energy consumption and lower operating costs compared with three other conventional hot-water schemes.


2018 ◽  
Vol 132 ◽  
pp. 1-13 ◽  
Author(s):  
Fujun Ju ◽  
Xiaowei Fan ◽  
Yaping Chen ◽  
Tuanjie Wang ◽  
Xiangyang Tang ◽  
...  