scholarly journals Case report - pre-transplant testing and post-transplant monitoring for an HLA-immunized recipient in heart transplantation

2020 ◽  
Vol 3 (1) ◽  
pp. 52-56
Author(s):  
Lucija Jukic ◽  
Biserka Palfi ◽  
Bosko Skoric ◽  
Marija Burek Kamenaric

We report the workflow of immunogenetic pre-transplant testing and post-transplant monitoring in the case of a recipient immunized to human leucocyte antigens (HLA) who was waitlisted for heart transplantation. The recipient underwent heart transplantation across preformed HLA class I Donor Specific Antibodies (DSAs) detected by solid phase Luminex screening method but not by complement dependent cytotoxicity (CDC) screening method. The CDC lymphocyte crossmatch, which was performed retrospectively, was a weak positive. Post-transplant DSA monitoring by Luminex method revealed the decrease of HLA-A1, A25 and B57 DSAs with, at the same time, an increase of HLA-B8 DSA, as well as weak transient non-DSA HLA-DP antibodies. This case presents the importance of extensive immunogenetic testing and monitoring for identifying recipients with increased immunological risk for successful heart transplantation.

Blood ◽  
2021 ◽  
Vol 138 (Supplement 1) ◽  
pp. 1798-1798
Author(s):  
Rebeca Bailen ◽  
Jose Luis Vicario ◽  
Beatriz Herruzo ◽  
Luisa Maria Guerra ◽  
Ana Vallés ◽  
...  

Abstract Background. Donor specific antibodies (DSAs) are preformed IgG antibodies with specificity against HLA molecules not shared with the donor that can lead to graft failure (GF) in the setting of mismatched HSCT. The aim of this study is to report the experience of the Spanish Group of Hematopoietic Transplant (GETH-TC) in patients with DSAs undergoing haplo-HSCT. Methods. Patients undergoing haplo-HSCT in centers from the GETH-TC from 2013 to 2021 were included in the study. DSAs were analyzed with a solid-phase single-antigen immunoassay (Luminex®); monitoring was performed prior to desensitization, prior to infusion and after infusion. Desensitization strategies used depended on center experience, immunofluorescence intensity, complement fixation and type of antibodies. Results. 59 haplo-HSCT with DSAs were performed in 57 patients in 13 centers. Characteristics of the population are shown in Table 1. 53 (93%) patients were female (91% with prior pregnancies). All patients lacked a suitable alternative donor. 51 (89%) received peripheral blood as stem cell source. Conditioning was myeloablative in 58% and all patients received post-transplant cyclophosphamide based GVHD prophylaxis; 3 (5%) patients received also ATG. 28 (49%) patients presented anti-HLA class I DSAs 22 of them with >5000MFI), 14 (25%) presented anti-HLA class II (6 with >5000MFI) and 15 (26%) presented both anti-HLA class I and II DSAs (13 with >5000MFI). Five patients did not receive desensitization treatment, 4 of them with <5000MFI. Of 52 patients receiving desensitization treatment, 49 received at least two treatments as desensitization strategy and all but 3 (6%) experienced a decrease of MFI after desensitization (mean reduction 80%); 2 out of those 3 patients developed GF. Desensitization treatments used included RTX in 83% of patients, IVIG (65%), therapeutic plasma exchange (TPE) (60%), incompatible platelets (16%), MMF (42%), buffy coat (only in patients with class II DSAs, 23%), tacrolimus (21%), bortezomib (4%) and steroids (2%). Cumulative incidence of neutrophil engraftment at day 30 was 74% (Figure 1), in a median of 18 days (IQR, 15-20); five patients died before engraftment due to toxicity and 7 patients experienced primary GF despite desensitization in 6 of them. 4 of them received a 2 nd transplant, one was alive after day 100. 30 (53%) patients died during the study period: 6 due to GF, 7 due to relapse, 7 due to infection, 6 due to endothelial complications (SOS, TA-TMA and diffuse alveolar hemorrhage) and 4 because of GVHD. After a median follow-up of 24 months, 2-year OS and EFS were 52% and 42%, respectively. 2-year cumulative incidence of relapse at was 14% and NRM was 41%. Cumulative incidence of grade II-IV aGVHD at day 180 was 13% and chronic GVHD was 25%. Conclusions. The use of desensitization treatment guided by DSAs intensity kinetics constitute an effective approach with high rates of engraftment for patients with DSAs in need for an haplo-HSCT lacking an alternative suitable donor, including non-malignant disorders. Figure 1 Figure 1. Disclosures Bailen: Pfizer, Kite-Gilead, Gilead: Honoraria. Oarbeascoa: Gilead: Honoraria, Speakers Bureau. Kwon: Novartis, Celgene, Gilead, Pfizer: Consultancy, Honoraria.


2021 ◽  
Vol 12 ◽  
Author(s):  
Rebeca Bailén ◽  
José Luis Vicario ◽  
Laura Solán ◽  
Irene Sánchez-Vadillo ◽  
Pilar Herrera ◽  
...  

BackgroundDonor specific antibodies (DSAs) can be responsible for graft failure (GF) in the setting of mismatched hematopoietic stem cell transplantation (HSCT). The aim of our study is to report the experience of the Madrid Group of Hematopoietic Transplant (GMTH) in patients with DSAs undergoing haplo-HSCT.MethodsPatients undergoing haplo-HSCT in centers from the GMTH from 2012 to 2020 were included in the study. DSAs were analyzed with a solid-phase single-antigen immunoassay; monitoring was performed during desensitization on days -14, -7, 0 and in a weekly basis until neutrophil engraftment. Desensitization strategies varied depending on center experience, immunofluorescence intensity, complement fixation and type of antibodies.ResultsWe identified a total of 20 haplo-HSCT in 19 patients performed with DSAs in 5 centers. 10 (53%) patients presented anti-HLA class I DSAs (6 of them with > 5000 mean fluorescence intensity (MFI)), 4 (21%) presented anti-HLA class II (1 with > 5000 MFI) and 5 (26%) presented both anti-HLA class I and II (5 with > 5000 MFI). 90% of patients received at least two treatments as desensitization strategy and all experienced a decrease of MFI after desensitization (mean reduction 74%). Only one patient who developed progressive increase of MFI after infusion developed GF. Desensitization treatments used included rituximab, immunoglobulins, therapeutic plasma exchange, incompatible platelets, buffy coat and immunosuppressors. Seventeen (90%) patients achieved neutrophil engraftment; one patient died before engraftment because of infection and one patient with class I DSAs developed primary GF despite an intensive desensitization. After a median follow-up of 10 months, OS and EFS were 60% and 58%, respectively, cumulative incidence of relapse was 5% and NRM was 32%.ConclusionsDespite the optimal strategy of DSAs desensitization remains unclear, the use of desensitization treatment guided by DSAs intensity kinetics constitute an effective approach with high rates of engraftment for patients with DSAs in need for an haplo-HSCT lacking an alternative suitable donor.


Hematology ◽  
2017 ◽  
Vol 2017 (1) ◽  
pp. 645-650 ◽  
Author(s):  
Douglas E. Gladstone ◽  
Maria P. Bettinotti

Abstract Allogenic hematopoietic stem cell recipients may have preformed antibodies directed against foreign HLA antigens. The use of partially HLA-mismatched allogeneic hematopoietic stem cell donors allows for the possibility of the presence of circulating HLA donor-specific antibodies (DSAs) in the recipient. The presence of DSAs at the time of stem cell infusion increases the risk of primary graft failure. More recently developed technology using solid phase immunoassays (SPIs) with fluorochrome-conjugated beads has greatly improved the ability to detect and classify DSAs. When used in combination with the classic lymphocytotoxic complement-dependent and flow cytometric crossmatch tests, SPIs help provide DSA strength assessment. Parous females frequently harbor DSAs. DSAs tend to be of higher intensity when directed against haploidentical first-degree relatives. DSA assessment requires frequent monitoring as their relative strength can change over time. Although the criteria that constitutes a prohibitive DSA is unknown, desensitization techniques can result in engraftment rates as experienced in fully HLA-matched allogeneic blood or marrow transplantation recipients.


2018 ◽  
Vol 37 (4) ◽  
pp. S423-S424
Author(s):  
I. Mahoney ◽  
A. Young ◽  
N. Shekiladze ◽  
A. Morris ◽  
D. Gupta ◽  
...  

2016 ◽  
Vol 2016 ◽  
pp. 1-8 ◽  
Author(s):  
José M. Arreola-Guerra ◽  
Natalia Castelán ◽  
Adrián de Santiago ◽  
Adriana Arvizu ◽  
Norma Gonzalez-Tableros ◽  
...  

The aim of the present study was to describe the association of positive flow cross match (FXM) and C1q-SAB.Methods. In this observational, cross-sectional, and comparative study, patients included had negative AHG-CDC-XM and donor specific antibodies (DSA) and were tested with FXM. All pretransplant sera were tested with C1q-SAB assay.Results. A total of 50 donor/recipient evaluations were conducted; half of them had at least one C1q+ Ab (n=26, 52%). Ten patients (20.0%) had DSA C1q+ Ab. Twenty-five (50%) FXMs were positive. Factors associated with a positive FXM were the presence of C1q+ Ab (DSA C1q+ Ab: OR 27, 2.80–259.56,P=0.004, and no DSA C1q+ Ab: OR 5, 1.27–19.68,P=0.021) and the DSA LABScreen-SAB MFI (OR 1.26, 95% CI 1.06–1.49,P=0.007). The cutoff point of immunodominant LABScreen SAB DSA-MFI with the greatest sensitivity and specificity to predict FXM was 2,300 (sensitivity: 72% and specificity: 75%). For FXM prediction, DSA C1q+ Ab was the most specific (95.8%, 85–100) and the combination of DSA-MFI > 2,300 and C1q+ Ab was the most sensitive (92.0%, 79.3–100).Conclusions. C1q+ Ab and LABScreen SAB DSA-MFI were significantly associated with FXM. DSA C1q+ Ab was highly specific but with low sensitivity.


Sign in / Sign up

Export Citation Format

Share Document