scholarly journals Perspective: Humanized Pig Models of Bladder Cancer

2021 ◽  
Vol 8 ◽  
Author(s):  
Natália Vieira Segatto ◽  
Camila Bonemann Bender ◽  
Fabiana Kommling Seixas ◽  
Kyle Schachtschneider ◽  
Lawrence Schook ◽  
...  

Bladder cancer (BC) is the 10th most common neoplasia worldwide and holds expensive treatment costs due to its high recurrence rates, resistance to therapy and the need for lifelong surveillance. Thus, it is necessary to improve the current therapy options and identify more effective treatments for BC. Biological models capable of recapitulating the characteristics of human BC pathology are essential in evaluating the effectiveness of new therapies. Currently, the most commonly used BC models are experimentally induced murine models and spontaneous canine models, which are either insufficient due to their small size and inability to translate results to clinical basis (murine models) or rarely spontaneously observed BC (canine models). Pigs represent a potentially useful animal for the development of personalized tumors due to their size, anatomy, physiology, metabolism, immunity, and genetics similar to humans and the ability to experimentally induce tumors. Pigs have emerged as suitable biomedical models for several human diseases. In this sense, the present perspective focuses on the genetic basis for BC; presents current BC animal models available along with their limitations; and proposes the pig as an adequate animal to develop humanized large animal models of BC. Genetic alterations commonly found in human BC can be explored to create genetically defined porcine models, including the BC driver mutations observed in the FGFR3, PIK3CA, PTEN, RB1, HRAS, and TP53 genes. The development of such robust models for BC has great value in the study of pathology and the screening of new therapeutic and diagnostic approaches to the disease.

2011 ◽  
Vol 2011 ◽  
pp. 1-10 ◽  
Author(s):  
Yoriyasu Suzuki ◽  
Alan C. Yeung ◽  
Fumiaki Ikeno

To improve human health, scientific discoveries must be translated into practical applications. Inherent in the development of these technologies is the role of preclinical testing using animal models. Although significant insight into the molecular and cellular basis has come from small animal models, significant differences exist with regard to cardiovascular characteristics between these models and humans. Therefore, large animal models are essential to develop the discoveries from murine models into clinical therapies and interventions. This paper will provide an overview of the more frequently used large animal models, especially porcine models for preclinical studies.


2021 ◽  
Vol 22 (11) ◽  
pp. 6092
Author(s):  
Bastian Amend ◽  
Niklas Harland ◽  
Jasmin Knoll ◽  
Arnulf Stenzl ◽  
Wilhelm K. Aicher

Stress urinary incontinence (SUI) is a significant health concern for patients affected, impacting their quality of life severely. To investigate mechanisms contributing to SUI different animal models were developed. Incontinence was induced under defined conditions to explore the pathomechanisms involved, spontaneous recovery, or efficacy of therapies over time. The animal models were coined to mimic known SUI risk factors such as childbirth or surgical injury. However, animal models neither reflect the human situation completely nor the multiple mechanisms that ultimately contribute to the pathogenesis of SUI. In the past, most SUI animal studies took advantage of rodents or rabbits. Recent models present for instance transgenic rats developing severe obesity, to investigate metabolic interrelations between the disorder and incontinence. Using recombinant gene technologies, such as transgenic, gene knock-out or CRISPR-Cas animals may narrow the gap between the model and the clinical situation of patients. However, to investigate surgical regimens or cell therapies to improve or even cure SUI, large animal models such as pig, goat, dog and others provide several advantages. Among them, standard surgical instruments can be employed for minimally invasive transurethral diagnoses and therapies. We, therefore, focus in this review on large animal models of SUI.


2017 ◽  
Vol 28 (1) ◽  
pp. 31-43 ◽  
Author(s):  
Lan Huang ◽  
Fengyan Zhao ◽  
Yi Qu ◽  
Li Zhang ◽  
Yan Wang ◽  
...  

AbstractHypoxic-ischemic encephalopathy (HIE), a serious disease leading to neonatal death, is becoming a key area of pediatric neurological research. Despite remarkable advances in the understanding of HIE, the explicit pathogenesis of HIE is unclear, and well-established treatments are absent. Animal models are usually considered as the first step in the exploration of the underlying disease and in evaluating promising therapeutic interventions. Various animal models of HIE have been developed with distinct characteristics, and it is important to choose an appropriate animal model according to the experimental objectives. Generally, small animal models may be more suitable for exploring the mechanisms of HIE, whereas large animal models are better for translational studies. This review focuses on the features of commonly used HIE animal models with respect to their modeling strategies, merits, and shortcomings, and associated neuropathological changes, providing a comprehensive reference for improving existing animal models and developing new animal models.


Author(s):  
Peter W. Walsh ◽  
Craig S. McLachlan ◽  
Leigh Ladd ◽  
Arie Blitz ◽  
R. Mark Gillies ◽  
...  

Numerous large animal models of chronic cardiac ischemia have been developed to explore either pathological mechanisms and or device interventions in developed heart failure models. Traditionally chronic heart failure in large animal models such as sheep or pigs has been induced by either coronary ligation with or without reperfusion. Coronary ligation is often attempted in the open chest surgical model or more recently in the closed chest animal via angiography [1]. Both techniques can be challenging and also induce high mortality with the risk of myocardial stunning and resultant shock and or lethal arrhythmias. There is also difficulty in developing stable heart failure across cases where infarct sizes can be variable. One strategy to over come this variability has been via rapid ventricular pacing, however inducing heart failure does not induce sustained heart failure in many cases if the pacing is switched off, and additionally pacing does not induce some of the underlying pathology seen in the development of heart failure [1].


Cells ◽  
2021 ◽  
Vol 10 (3) ◽  
pp. 713
Author(s):  
Shu Fang ◽  
Ditte Gry Ellman ◽  
Ditte Caroline Andersen

To date, a wide range of materials, from synthetic to natural or a mixture of these, has been explored, modified, and examined as small-diameter tissue-engineered vascular grafts (SD-TEVGs) for tissue regeneration either in vitro or in vivo. However, very limited success has been achieved due to mechanical failure, thrombogenicity or intimal hyperplasia, and improvements of the SD-TEVG design are thus required. Here, in vivo studies investigating novel and relative long (10 times of the inner diameter) SD-TEVGs in large animal models and humans are identified and discussed, with emphasis on graft outcome based on model- and graft-related conditions. Only a few types of synthetic polymer-based SD-TEVGs have been evaluated in large-animal models and reflect limited success. However, some polymers, such as polycaprolactone (PCL), show favorable biocompatibility and potential to be further modified and improved in the form of hybrid grafts. Natural polymer- and cell-secreted extracellular matrix (ECM)-based SD-TEVGs tested in large animals still fail due to a weak strength or thrombogenicity. Similarly, native ECM-based SD-TEVGs and in-vitro-developed hybrid SD-TEVGs that contain xenogeneic molecules or matrix seem related to a harmful graft outcome. In contrast, allogeneic native ECM-based SD-TEVGs, in-vitro-developed hybrid SD-TEVGs with allogeneic banked human cells or isolated autologous stem cells, and in-body tissue architecture (IBTA)-based SD-TEVGs seem to be promising for the future, since they are suitable in dimension, mechanical strength, biocompatibility, and availability.


Author(s):  
Amira D. Rghei ◽  
Brenna A. Y. Stevens ◽  
Sylvia P. Thomas ◽  
Jacob G. E. Yates ◽  
Benjamin M. McLeod ◽  
...  

2012 ◽  
Vol 78 (8) ◽  
pp. 1733-1748 ◽  
Author(s):  
G.P. Adams ◽  
J. Singh ◽  
A.R. Baerwald

Sign in / Sign up

Export Citation Format

Share Document