scholarly journals Five-Years Angiographic Follow-Up of Wide-Neck Intracranial Aneurysms Treated With LEO Plus Stent

2021 ◽  
Vol 12 ◽  
Author(s):  
José M. Pumar ◽  
Paula Sucasas ◽  
Antonio Mosqueira ◽  
Pedro Vega ◽  
Eduardo Murias

Background: This study aimed to evaluate the angiographic and clinical outcome, with an emphasis on long-term follow-up, of the LEO Plus stent for wide-neck intracranial aneurysms treated in a single center.Methods: We retrospectively examined a prospectively maintained database of patients treated with LEO Plus devices between January 2004 and December 2016. Data regarding patient demographics, aneurysm characteristics, and technical procedures were analyzed. Angiographic and clinical findings were recorded during the procedure and followed up over a period of at least 5 years.Results: We identified 101 patients with 116 aneurysms. In 16 patients, the stent could not safely be placed. Thus, a total of 97 LEO Plus devices were implanted in 97 aneurysms of 85 patients. Adverse events (acute and delayed) were observed in 21.6% of cases (17/85), and most were resolved (70.6%; 12/17). Moreover, 5 years after the procedure, total morbidity and mortality were 2.3% (2/85) and 3.5% (3/85), respectively. Long-term imaging follow-up showed complete occlusions, neck remnants, and residual aneurysms in 73.1% (57/78), 14.1% (11/78), and 12.8% (10/78) of cases, respectively.Conclusions: Long-term results of treatment of brain aneurysms with LEO stent show high rates of adequate and stable occlusion over time, with acceptable morbidity and mortality.

2017 ◽  
Vol 10 (2) ◽  
pp. 127-132 ◽  
Author(s):  
Benjamin Mine ◽  
Alexandra Goutte ◽  
Denis Brisbois ◽  
Boris Lubicz

PurposeTo evaluate the clinical and anatomical results of treatment of intracranial aneurysms (IA) with the Woven EndoBridge (WEB) device, with emphasis on mid term and long term follow-up.MethodsBetween November 2010 and November 2015, we retrospectively identified, in our prospectively maintained database, all patients treated by WEB device placement for an IA at three institutions. Clinical charts, procedural data, and angiographic results were reviewed.Results48 patients with 49 IAs were identified. There were 35 women and 13 men with a mean age of 57 years (range 35–76 years). All IA were wide necked. Mean aneurysm size was 8.6 mm. There were 44 unruptured IA and 5 ruptured IA. During endovascular treatment (EVT), adjunctive devices were used in 22.4% of procedures. A good clinical outcome (modified Rankin Scale score ≤2) was achieved in 44/48 patients (92%). There was no mortality. Mean follow-up was 25 months (range 3–72 months; median 24 months). Between mid term and long term follow-up, occlusion was stable in 19/23 IA (82.6%), improved in 2/23 IA (8.7%), and worsened in 2/23 IA (8.7%). Retreatment was performed in 8/49 IA (16.3%). At the latest available follow-up, there were 34/47 (72.3%) complete occlusions and 13/47 (27.7%) neck remnants.ConclusionsOur study suggests that EVT of IA with the WEB device provides adequate and stable long term occlusion.


2021 ◽  
Author(s):  
Marta Aguilar Pérez ◽  
Elina Henkes ◽  
Victoria Hellstern ◽  
Carmen Serna Candel ◽  
Christina Wendl ◽  
...  

Abstract BACKGROUND Flow diverters have become an important tool in the treatment of intracranial aneurysms, especially when dealing with difficult-to-treat or complex aneurysms. The p64 is the only fully resheathable and mechanically detachable flow diverter available for clinical use. OBJECTIVE To evaluate the safety and effectiveness of p64 for the treatment of intracranial saccular unruptured aneurysms arising from the anterior circulation over a long-term follow-up period. METHODS We retrospectively reviewed our prospectively maintained database to identify all patients who underwent treatment for an intracranial saccular (unruptured or beyond the acute hemorrhage phase) aneurysm arising from the anterior circulation with ≥1 p64 between December 2011 and December 2019. Fusiform aneurysms and dissections were excluded. Aneurysms with prior or concomitant saccular treatment (eg, coiling and clipping) were included. Aneurysms with parent vessel implants other than p64 were excluded. Anatomic features, intraprocedural complications, clinical outcome, as well as clinical and angiographic follow-ups were all recorded. RESULTS In total, 530 patients (388 females; median age 55.9 yr) with 617 intracranial aneurysms met the inclusion criteria. The average number of devices used per aneurysm was 1.1 (range 1-3). Mean aneurysm dome size was 4.8 mm (range 1-27 mm). Treatment-related morbimortality was 2.4%. Early, mid-term, and long-term angiographic follow-up showed complete or near-complete aneurysm occlusion in 76.8%, 89.7%, and 94.5%, respectively. CONCLUSION Treatment of intracranial saccular unruptured aneurysms of the anterior circulation using p64 is a safe and effective treatment option with high rate of occlusion at long-term follow-up and low morbimortality.


2018 ◽  
Vol 11 (5) ◽  
pp. 516-522 ◽  
Author(s):  
Idriss Haffaf ◽  
Frédéric Clarençon ◽  
Eimad Shotar ◽  
Claudia Rolla-Bigliani ◽  
Saskia Vande Perre ◽  
...  

Background and purposeThe Medina embolization device (MED) is a new flow disruption device combining the design of a detachable coil with an intrasaccular flow disrupter. Safety and short-term angiographic effectiveness of this device have recently been reported. However, long-term angiographic results are lacking. We report herein the 18 months’ angiographic outcome in patients treated for a wide-neck intracranial aneurysm with the MED.Materials and methodsNineteen patients (17 female, mean age 50 years) with 20 wide-neck intracranial aneurysms (six ruptured; 14 unruptured) were treated by the MED between January 2015 and June 2016. Procedure-related complications were systematically recorded; discharge and 6–9 months' follow-up modified Rankin Scale scores were assessed. Angiographic mid-term and long-term follow-up were performed with a mean delay of 6.4±1.5 months (n=16 aneurysms) and 17.7±4.2 months (n=15 aneurysms), respectively. Occlusion rates were evaluated after the procedure and at the mid-term and long-term follow-up using the Roy-Raymond scale.ResultsEmbolization with the MED was feasible in all except two cases (2/20, 10%). One per-procedural perforation was recorded (1/20, 5%) and one MED deployment failed because of the aneurysm’s shape (1/20, 5%). Three cases of thromboembolic complications were observed (3/20, 15%). Only one thromboembolic complication was responsible for clinical sequelae. Grade A occlusion rate was 61% (11/18) after the procedure, 75% at 6 months' follow-up (12/16), and 80% (12/15) at long-term follow-up. Two cases (2/18, 11%) of recanalization at mid-term were documented angiographically. No recanalization occurred between the mid-term and long-term follow-up.ConclusionMED is a hybrid embolization device, combining properties of a conventional coil with those of an intrasaccular flow disrupter. Our series focusing on long-term angiographic follow-up shows a satisfactory long-term occlusion rate. Larger series with longer angiographic follow-up times are warranted to confirm these preliminary results.


Author(s):  
Vitalii І. Kravchenko

Acute aortic dissection is a formidable disease. Its prevalence increases due to the population aging, as well as wider awareness of physicians about this pathology. The aim. To analyze immediate and long-term results of surgical treatment of aneurysms of ascending aorta and aortic arch and to determine optimal methods of correction of these lesions in order to improve the results of surgical treatment. Materials and methods. This was a comparative analysis of immediate and long-term treatment outcomes in 419 patients with aneurysms of ascending aorta and aortic arch. A comparative analysis of the results of treatment of two groups of patients was performed: the comparison group of 157 people operated before 2013, and the main group of 262 patients operated since 2013 using modified methods of aortic surgery. Results. The study showed significant reduction in the left ventricular dilatation according to echocardiography and satisfactory postoperative course in patients of both groups. Patients with valve-sparing aortic prosthetics had better results than those who underwent valve replacement surgery. Hospital mortality decreased from 17.2% to 5.3%. Analysis of long-term results showed that supracoronary aortic prosthetics with aortic valve plasty and elimination of the intimal tear zone make it possible to carry out effective aortic reconstruction. Due to events in the long run, regular lifelong monitoring is required. The analysis also showed that individualized approach to the choice of surgical tactics for the correction of aortic insufficiency in patients with aortic root and ascending aortic pathology allows to achieve comparable results in the immediate and long-term follow-up. Despite the complexity of the applied correction methods, the developed methods of surgical treatment of ascending aortic aneurysm (AAA) and aortic arch aneurysm and methods of protection of brain and visceral organs allowed to keep hospital mortality and the number of complications at the same level corresponding to one of the best world results. This gives hope for a good result in the long-term follow-up. Conclusions. Aneurysm of ascending aorta and aortic arch is a formidable life-threatening disease, and its only non-alternative treatment option is surgery. The optimized approach to the treatment of patients in the main group allowed to obtain better immediate and long-term results of surgical treatment and reduce postoperative complications from 34.4% to 8.4% and hospital mortality from 17.2% to 5.3%. Comparative analysis of long-term results in the studied groups showed more encouraging indicators of quality of life and life expectancy in patients when using modified surgical techniques, protection of the brain and visceral organs. We hope to get a final assessment of these data in the further study of the condition of these patients in the long-term follow-up.


2014 ◽  
Vol 8 (2) ◽  
pp. 158-162 ◽  
Author(s):  
Nicola Limbucci ◽  
Leonardo Renieri ◽  
Sergio Nappini ◽  
Arturo Consoli ◽  
Andrea Rosi ◽  
...  

BackgroundY-stent assisted coiling has been proposed for the treatment of wide-neck bifurcation aneurysms, but there are many technical variations. We report our single-center experience of Y-stent assisted coiling of bifurcation aneurysms with the closed cell Enterprise stent in order to evaluate the safety and long-term results of this technique. The literature on Y-stenting and its hemodynamic effects are reviewed.MethodsFifty-two consecutive patients with wide-neck bifurcation aneurysms underwent Y-stent assisted coiling with two Enterprise stents. The procedure was completed in 48 cases (92.3%) and technical failure occurred in 4 cases (7.3%). Cases performed with other stents were excluded. All procedures were performed under double antiplatelet therapy. Periodic clinical and neuroradiological follow-up was performed.ResultsMean neuroradiological follow-up time was 26 months. Complete immediate occlusion was obtained in 87.5% of patients. Two remnants had regrown at follow-up and were recoiled, achieving complete occlusion. The late neuroradiological occlusion rate was: complete occlusion 93.6%, neck remnant 4.3%, sac remnant 2.1%. No in-stent stenosis was detected at follow-up. Among the 48 procedures, two complications occurred (4.2%). Mortality was 2.1%. No delayed ischemic stroke occurred.ConclusionsY-stent assisted coiling has a high immediate occlusion rate and very good long-term stability. The procedure is relatively safe, although the complication and mortality rates are not negligible. Two Enterprise stents can be safely used for Y-stenting and, indeed, offer the advantage of easier catheterization, delivery and deployment into distal and tortuous vessels than open cell stents.


2017 ◽  
Vol 10 (7) ◽  
pp. 669-674 ◽  
Author(s):  
Nicholas K Cheung ◽  
Albert HY Chiu ◽  
Andrew K Cheung ◽  
Jason D Wenderoth

BackgroundPreliminary short-term results for stent-assisted coil embolization (SACE) using woven/braided stents have been promising. However, evidence supporting mid- to long-term efficacy and durability is lacking.ObjectiveTo report the long-term results for the durability of elective intracranial aneurysms treated with woven stents.Materials and methodsBetween May 2012 and May 2015, 98 consecutive patients with 103 aneurysms underwent elective woven SACE across three Australian neurovascular centres. All patients had immediate, 6- and 18-month clinical and radiological follow-up. Radiological assessment was performed with modified Raymond–Roy occlusion scores based on angiography results, while clinical assessment was based on the modified Rankin Scale.ResultsSix-month follow-up was available in 100 aneurysms, and an 18-month follow-up in 97 aneurysms. Total occlusion rates of 82% were achieved at inception, 82% at 6 months, and 90% at 18 months. Satisfactory occlusion with small neck remnants was present in 17% at inception, 16% at 6 months, and 9% at 18 months. Good neurological outcomes were achieved in 95% at 18 months. Intraprocedural thromboembolic events were recorded in 3% and delayed events in 1% (all in patients taking clopidogrel). Aneurysm recurrence occurred in one patient (1%). Technical complications occurred in 5%. The total complication rate was 10%.ConclusionsWoven SACE is safe, efficacious, and durable at long-term 18-month follow-up, with very low recurrence and re-treatment rates. Preliminary results appear better than those for traditional laser-cut stents.


2021 ◽  
pp. 159101992110402
Author(s):  
Adrien Guenego ◽  
Benjamin Mine ◽  
Thomas Bonnet ◽  
Stephanie Elens ◽  
Juan Vazquez Suarez ◽  
...  

Purpose Wide-neck bifurcation aneurysms remain challenging for the neurointerventionist and/or neurosurgeon despite many recent advances. The pCONus (Phenox, Bochum, Germany) is an emerging device for endovascular neck protection, we report the first long-term results of this device. Methods We performed a retrospective analysis of all consecutive intracranial wide-neck bifurcation aneurysms treated with the pCONus. Patients' characteristics were reviewed, procedural complications, angiographic (Roy-Raymond scale) and clinical outcomes were documented. Results Between January 2016 and September 2019, 43 patients (74% female, median age 56 [49–66] years) with 43 wide-neck bifurcation aneurysms (mean width of 6.8 ± 2.1 mm, dome/neck ratio of 1.3 ± 0.2 and neck of 5.2 ± 1.3 mm) were included. A procedural angiographic complication was reported in five patients (12%), no patient presented a post-operative neurological deficit or long-term complication, mortality rate was 0%. At last follow-up (median of 46.5 months [38.3–51.7]), an adequate occlusion (complete and neck remnant) was observed in 37/43 patients (86%) and an aneurysm remnant in 6/43 (14%). Four patients (9%) needed retreatment. No in-stent stenosis or branch occlusion was depicted. Conclusion pCONus device provides a safe and efficient alternative for endovascular wide-neck bifurcation aneurysms management, with long-term stability.


2020 ◽  
pp. 159101992098433
Author(s):  
Ali Burak Binboga ◽  
Mehmet Onay ◽  
Cetin Murat Altay

Background The objective of this study was to present the long-term safety and effectiveness of strand remodelling with a hypercompliant balloon. Methods Patients with complex wide-neck bifurcation aneurysms (WNBAs) who underwent strand remodelling with a hypercompliant balloon via Y-stent-assisted coil embolization (Y-SACE) between September 2016 and January 2020 were included in the study. The feasibility, safety, effectiveness, and complication rates of the strand remodelling technique were investigated. Results A total of 12 patients (6 females, 6 males) were included in this study. Significant expansion was obtained in the intersection zone after remodelling. No regression was observed in the expansion rates during follow-up. There was no additional morbidity or mortality. No delayed thromboembolic complications occurred in our patients during long-term follow-up. Conclusions Performing strand remodelling to reduce thromboembolic complications triggered by structural faults caused by the Y-stent configuration is feasible, safe, and effective. This new approach can aid in the prevention of thromboembolic complications in Y-SACE.


2010 ◽  
Vol 16 (3) ◽  
pp. 231-239 ◽  
Author(s):  
L.M. Pyysalo ◽  
L.H. Keski-Nisula ◽  
T.T. Niskakangas ◽  
V.J. Kähärä ◽  
J.E. Öhman

Long-term follow-up studies after endovascular treatment for intracranial aneurysm are still rare and inconclusive. The aim of this study was to assess the long-term clinical and angiographic outcome of patients with endovascularly treated aneurysms. The clinical outcome of all 185 patients with endovascularly treated aneurysms were analyzed and 77 out of 122 surviving patients were examined with MRI and MRA nine to 16 years (mean 11 years) after the initial endovascular treatment. Sixty-three patients were deceased at the time of follow-up. The cause of death was aneurysm-related in 34 (54%) patients. The annual rebleeding rate from the treated aneurysms was 1.3% in the ruptured group and 0.1% in the unruptured group. In long-term follow-up MRA 18 aneurysms (53%) were graded as complete, 11 aneurysms (32%) had neck remnants and five aneurysms (15%) were incompletely occluded in the ruptured group. The occlusion grade was lower in the unruptured group with 20 aneurysms (41%) graded as complete, 11 (22%) had neck remnants and 18 (37%) were incomplete. However, only three aneurysms were unstable during the follow-up period and needed retreatment. Endovascular treatment of unruptured aneurysms showed incomplete angiographic outcome in 37% of cases. However, the annual bleeding rate was as low as 0.1%. Endovascular treatment of ruptured aneurysms showed incomplete angiographic outcome in 15% of cases and the annual rebleeding rate was 1,3%.


2017 ◽  
Vol 59 (6) ◽  
pp. 619-624 ◽  
Author(s):  
Boris Lubicz ◽  
Ricardo Morais ◽  
Pierre-Julien Bruyère ◽  
Noémie Ligot ◽  
Benjamin Mine

Sign in / Sign up

Export Citation Format

Share Document