scholarly journals Feasibility of Determination of Foodborne Microbe Contamination of Fresh-Cut Shredded Cabbage Using SW-NIR

2019 ◽  
Vol 1 (2) ◽  
pp. 246-256
Author(s):  
Benjamaporn Matulaprungsan ◽  
Chalermchai Wongs-Aree ◽  
Pathompong Penchaiya ◽  
Phonkrit Maniwara ◽  
Sirichai Kanlayanarat ◽  
...  

Shredded cabbage is widely used in much ready-to-eat food. Therefore, rapid methods for detecting and monitoring the contamination of foodborne microbes is essential. Short wavelength near infrared (SW-NIR) spectroscopy was applied on two types of solutions, a drained solution from the outer surface of the shredded cabbage (SC) and a ground solution of shredded cabbage (GC) which were inoculated with a mixture of two bacterial suspensions, Escherichia coli and Salmonella typhimurium. NIR spectra of around 700 to 1100 nm were collected from the samples after 0, 4, and 8 h at 37 °C incubation, along with the growth of total bacteria, E. coli and S. typhimurium. The raw spectra were obtained from both sample types, clearly separated with the increase of incubation time. The first derivative, a Savitzky–Golay pretreatment, was applied on the GC spectra, while the second derivative was applied on the SC spectra before developing the calibration equation, using partial least squares regression (PLS). The obtained correlation (r) of the SC spectra was higher than the GC spectra, while the standard error of cross-validation (SECV) was lower. The ratio of prediction of deviation (RPD) of the SC spectra was higher than the GC spectra, especially in total bacteria, quite normal for the E. coli but relatively low for the S. typhimurium. The prediction results of microbial spoilage were more reliable on the SC than on the GC spectra. Total bacterial detection was best for quantitative measurement, as E. coli contamination could only be distinguished between high and low values. Conversely, S. typhimurium predictions were not optimal for either sample type. The SW-NIR shows the feasibility for detecting the existence of microbes in the solution obtained from SC, but for a more specific application for discrimination or quantitation is needed, proving further research in still required.


2017 ◽  
Vol 62 (2) ◽  
pp. 3472-3477 ◽  
Author(s):  
MARIEL MONRROY ◽  
DEHYLIS GUTIÉRREZ ◽  
MARISSA MIRANDA ◽  
KARLA HERNÁNDEZ ◽  
JOSÉ RENÁN GARCÍA


2001 ◽  
Vol 9 (2) ◽  
pp. 133-139 ◽  
Author(s):  
L.G. Thygesen ◽  
S.B. Engelsen ◽  
M.H. Madsen ◽  
O.B. Sørensen

A set of 97 potato starch samples with a phosphate content corresponding to a phosphorus content between 0.029 and 0.11 g per 100 g dry matter was analysed using a Rapid Visco Analyzer (RVA) and near infrared (NIR) spectroscopy, (700–2498 nm). NIR-based prediction of phosphate content was possible with a root mean square error of cross-validation ( RMSECV) of 0.006% using PLSR (partial least squares regression). However, the NIR/PLSR model relied on weak spectral signals, and was highly sensitive to sample preparation. The best prediction of phosphate content from the RVA viscograms was a linear regression model based on the RVA variable Breakdown, which gave a RMSECV of 0.008%. NIR/PLSR prediction of the RVA variables Peak viscosity and Breakdown was successful, probably because they were highly related to phosphate content in the present data. Prediction of the other RVA variables from NIR/PLSR was mediocre (Through, Final Viscosity) or not possible (Setback, Peak time, Pasting temperature).



2020 ◽  
Vol 38 (No. 2) ◽  
pp. 131-136
Author(s):  
Wojciech Poćwiardowski ◽  
Joanna Szulc ◽  
Grażyna Gozdecka

The aim of the study was to elaborate a universal calibration for the near infrared (NIR) spectrophotometer to determine the moisture of various kinds of vegetable seeds. The research was conducted on the seeds of 5 types of vegetables – carrot, parsley, lettuce, radish and beetroot. For the spectra correlation with moisture values, the method of partial least squares regression (PLS) was used. The resulting qualitative indicators of a calibration model (R = 0.9968, Q = 0.8904) confirmed an excellent fit of the obtained calibration to the experimental data. As a result of the study, the possibilities of creating a calibration model for NIR spectrophotometer for non-destructive moisture analysis of various kinds of vegetable seeds was confirmed.<br /><br />



2013 ◽  
Vol 848 ◽  
pp. 313-316
Author(s):  
Xiao Li Yang ◽  
Fan Wang ◽  
Ji Shu Chen ◽  
Gong Zhe Ma

We studied moisture and volatile determination in bituminous coal samples using near-infrared (NIR) spectra. This research was developted by applying partial least squares regression (PLS) and discrete wavelet transform (DWT). Firstly, NIR spectra were pre-processed by DWT for fitting and compression. Then, DWT coefficients were used to build regression model with PLS. We used NIR spectra to determination moisture and volatile determination in coal samples seperately and simultaneously. Through parameters optimization, the results show that DWT-PLS can obtain satisfactory performance for separate and simultanous determination.



2020 ◽  
Vol 23 (8) ◽  
pp. 740-756
Author(s):  
Naifei Zhao ◽  
Qingsong Xu ◽  
Man-lai Tang ◽  
Hong Wang

Aim and Objective: Near Infrared (NIR) spectroscopy data are featured by few dozen to many thousands of samples and highly correlated variables. Quantitative analysis of such data usually requires a combination of analytical methods with variable selection or screening methods. Commonly-used variable screening methods fail to recover the true model when (i) some of the variables are highly correlated, and (ii) the sample size is less than the number of relevant variables. In these cases, Partial Least Squares (PLS) regression based approaches can be useful alternatives. Materials and Methods : In this research, a fast variable screening strategy, namely the preconditioned screening for ridge partial least squares regression (PSRPLS), is proposed for modelling NIR spectroscopy data with high-dimensional and highly correlated covariates. Under rather mild assumptions, we prove that using Puffer transformation, the proposed approach successfully transforms the problem of variable screening with highly correlated predictor variables to that of weakly correlated covariates with less extra computational effort. Results: We show that our proposed method leads to theoretically consistent model selection results. Four simulation studies and two real examples are then analyzed to illustrate the effectiveness of the proposed approach. Conclusion: By introducing Puffer transformation, high correlation problem can be mitigated using the PSRPLS procedure we construct. By employing RPLS regression to our approach, it can be made more simple and computational efficient to cope with the situation where model size is larger than the sample size while maintaining a high precision prediction.



2012 ◽  
Vol 622-623 ◽  
pp. 1532-1535
Author(s):  
Zhen Bo Liu ◽  
Wen Yang Kong ◽  
Yi Xing Liu ◽  
Zhan Chuan Xue ◽  
Xiao Yan Shen ◽  
...  

Many studies have successfully applied near infrared (NIR) spectroscopy to estimate important wood properties. In this paper, the use of NIR (350–2500 nm) spectroscopy to predict the cellulose crystallinity of Poplar (Populus nigra var.) was investigated. The calibration and test models were constructed using partial least squares regression (PLS). The correlations were significant both the calibration and the test samples using six factors, and the correlation coefficients (R2) were 0.9367, 0.9472 respectively. The results suggest that NIR spectroscope may provide a useful tool for rapid and accurate prediction of the cellulose crystallinity of Poplar.



1996 ◽  
Vol 26 (4) ◽  
pp. 590-600 ◽  
Author(s):  
Katherine L. Bolster ◽  
Mary E. Martin ◽  
John D. Aber

Further evaluation of near infrared reflectance spectroscopy as a method for the determination of nitrogen, lignin, and cellulose concentrations in dry, ground, temperate forest woody foliage is presented. A comparison is made between two regression methods, stepwise multiple linear regression and partial least squares regression. The partial least squares method showed consistently lower standard error of calibration and higher R2 values with first and second difference equations. The first difference partial least squares regression equation resulted in standard errors of calibration of 0.106%, with an R2 of 0.97 for nitrogen, 1.613% with an R2 of 0.88 for lignin, and 2.103% with an R2 of 0.89 for cellulose. The four most highly correlated wavelengths in the near infrared region, and the chemical bonds represented, are shown for each constituent and both regression methods. Generalizability of both methods for prediction of protein, lignin, and cellulose concentrations on independent data sets is discussed. Prediction accuracy for independent data sets and species from other sites was increased using partial least squares regression, but was poor for sample sets containing tissue types or laboratory-measured concentration ranges beyond those of the calibration set.



2015 ◽  
Vol 2015 ◽  
pp. 1-10 ◽  
Author(s):  
Xuesong Liu ◽  
Chunyan Wu ◽  
Shu Geng ◽  
Ye Jin ◽  
Lianjun Luan ◽  
...  

This paper used near-infrared (NIR) spectroscopy for the on-line quantitative monitoring of water precipitation during Danhong injection. For these NIR measurements, two fiber optic probes designed to transmit NIR radiation through a 2 mm flow cell were used to collect spectra in real-time. Partial least squares regression (PLSR) was developed as the preferred chemometrics quantitative analysis of the critical intermediate qualities: the danshensu (DSS, (R)-3, 4-dihydroxyphenyllactic acid), protocatechuic aldehyde (PA), rosmarinic acid (RA), and salvianolic acid B (SAB) concentrations. Optimized PLSR models were successfully built and used for on-line detecting of the concentrations of DSS, PA, RA, and SAB of water precipitation during Danhong injection. Besides, the information of DSS, PA, RA, and SAB concentrations would be instantly fed back to site technical personnel for control and adjustment timely. The verification experiments determined that the predicted values agreed with the actual homologic value.



Sign in / Sign up

Export Citation Format

Share Document