scholarly journals A Reversed-Phase HPLC Method for Determination of Osteopontin in Infant Formula

2019 ◽  
Vol 9 (18) ◽  
pp. 3711 ◽  
Author(s):  
Md Abdul Wazed ◽  
Mohammed Farid

Osteopontin (OPN) is a multifunctional whey protein which has recently received much attention for possibly applications in fortifying infant milk formula (IMF) with its bioactivity. However, to date, there is no established high-performance liquid chromatography (HPLC) method to quantify this protein in milk or IMF. In this study, a rapid, simple, isocratic and reliable reversed-phase HPLC method was developed and validated to quantify the OPN in IMF. A C18 column (4.6 × 150 mm × 5 micron) was employed with 20% of 0.1% trifluoroacetic acid (TFA) and 80% of 60% acetonitrile in 0.1% TFA for 10 min detected at 214 nm. The flow rate was 0.3 mL/min with an injection volume of 10 µL. The column temperature was 40 °C, and the peak appeared after 4 min. The validation was based on the system suitability, linearity (r2 = 0.999), limit of detection (LOD) (0.14 mg/L), limit of quantitation (LOQ) (0.41 mg/L), precision (% relative standard deviation (RSD) < 0.2), recovery (% RSD < 3) and robustness. The results confirm that the method developed is suitable for OPN determination in IMF.

Author(s):  
Dilshad Ahmad ◽  
Faisal A. Al Meshaiti ◽  
Yazeed K. Al Anazi ◽  
Osama Al Owassil ◽  
Alaa Eldeen B. Yassin

Anastrozole, an aromatase inhibitor drug, is used for the treatment of breast cancer in pre- and postmenopausal women. Anastrozole’s incorporation into nanoparticulate carriers would enhance its therapeutic performance. To perceive the exact loaded amount of drug in nanocarriers, a valid analytical method is required. The reversed-phase high-performance liquid chromatography (RP-HPLC) method was developed and validated by using the C18 column, 150 × 4.6 mm, 5 µm particle size, in isocratic mobile phase composed of 50:50 V/V (volume/volume) acetonitrile–phosphate buffer (pH 3) flowing at a rate of 1.0 mL/min, and a diode array detector (DAD) set at λmax = 215 nm. The validation parameters such as linearity, accuracy, specificity, precision, and robustness have proven the accuracy of the method, with the relative standard deviation percentage (% RSD) values < 2. The limit of detection of the method was found equal to 0.0150 µg/mL, and the limit of quantitation was 0.0607 µg/mL. The percent recovery of sample was in the range of 98.04–99.25%. The method has the advantage of being rapid with a drug retention time of 2.767 min, specific in terms of resolution of peaks void of interference with any of the excipients, and high reproducibility. This makes it highly applicable for quality control purposes.


2017 ◽  
Vol 9 (2) ◽  
pp. 34
Author(s):  
N. Balaji ◽  
Sayeeda Sultana

Objective: An efficient, high performance liquid chromatographic method has been developed and validated for the quantification of related substances in pioglitazone hydrochloride drug substance.Methods: This method includes the determination of three related substances in pioglitazone hydrochloride. The mobile phase A is 0.1% w/v triethylamine in water with pH 2.5 adjusted by dilute phosphoric acid. The mobile phase B is premixed and degassed mixtures of acetonitrile and methanol. The flow rate was 1 ml/min. The elution used was gradient mode. The HPLC column used for the analysis was symmetry C18 with a length of 250 mm, the internal diameter of 4.6 mm and particle size of 5.0 microns.Results: The developed method was found to be linear with the range of 0.006-250% with a coefficient of correlation 0.99. The precision study revealed that the percentage relative standard deviation was within the acceptable limit. The limit of detection and limit of quantitation of the impurities was less than 0.002%and 0.006% with respect to pioglitazone hydrochloride test concentration of 2000 µg/ml respectively. This method has been validated as per ICH guidelines Q2 (R1).Conclusion: A reliable, economical HPLC method was magnificently established for quantitative analysis of related substances of pioglitazone hydrochloride drug substance.


Author(s):  
İbrahim Bulduk

AbstractFavipiravir (FVP), a pyrazine analog, has shown antiviral activity against a wide variety of viruses. It is considered to be worth further investigation as a potential candidate drug for COVID-19. It is not officially available in any pharmacopoeia. A rapid, simple, precise, accurate, and isocratic high performance liquid chromatography (HPLC) method has been developed for routine quality control of favipiravir in pharmaceutical formulations. Separation was carried out by C18 column. The mobile phase was a mixture of 50 mM potassium dihydrogen phosphate (pH 2.3) and acetonitrile (90:10, v/v) at a flow rate of 1 mL min−1. The ultraviolet (UV) detection and column temperature were 323 nm, and 30 °C, respectively. The run time was 15 min under these chromatographic conditions. Excellent linear relationship between peak area and favipiravir concentration in the range of 10–100 μg mL−1 has been observed (r2, 0.9999). Developed method has been found to be sensitive (limits of detection and quantification were 1.20 μg mL−1 and 3.60 μg mL−1, respectively), precise (the interday and intraday relative standard deviation (RSD) values for peak area and retention time were less than 0.4 and 0.2%, respectively), accurate (recovery, 99.19–100.17%), specific and robust (% RSD were less than 1.00, for system suitability parameters). Proposed method has been successfully applied for quantification of favipiravir in pharmaceutical formulations.


2018 ◽  
Vol 17 (2) ◽  
pp. 175-182
Author(s):  
Joy Chandra Rajbangshi ◽  
Md Mahbubul Alam ◽  
Md Shahadat Hossain ◽  
Md Samiul Islam ◽  
Abu Shara Shamsur Rouf

This research was aimed to establish a versatile, sensitive, rapid and validated RP-HPLC method to analyze linagliptin in bulk as well as in pharmaceutical dosage forms. Liquid chromatography was performed on HPLC system and 20μl of samples were injected into a C18 column (150 x 4.6 mm i.d., 5μm particle size) and the eluents were monitored through a PDA detector at 239 nm. An isocratic method with a flow rate of 1 ml/min was used to elute the compounds with a mobile phase comprised of 70:30 v/v mixture of phosphate buffer (pH 6.8±0.2) and acetonitrile. The retention time of the compound was found to be 2.8 minutes. According to the ICH Q2(R1) guidelines, the method was validated by establishing several analytical parameters such as system suitability, specificity, linearity, accuracy, precision, limit of detection (LOD), limit of quantitation (LOQ), ruggedness and robustness to assay linagliptin. The method showed good linearity (R2 = 0.9981) over the concentration ranges of 40 – 60 μg/ml with a recovery between 99.48% ± 0.38% RSD to 100.22% ± 0.011% RSD, whereas the LOD and LOQ values were 0.05 μg/ml and 0.15 μg/ml, respectively. The relative standard deviation (% RSD) for inter-day and intra-day precision was not more than 2.0%. Hence, the proposed method can be applied accurately for research and routine analysis of linagliptin in bulk as well as different pharmaceutical dosage forms. Dhaka Univ. J. Pharm. Sci. 17(2): 175-182, 2018 (December)


2009 ◽  
Vol 63 (6) ◽  
Author(s):  
Hong Yan ◽  
Pei Xu ◽  
Hai Huang ◽  
Juan Qiu

AbstractA pre-column derivatized high-performance liquid chromatographic (HPLC) method with ultraviolet-visible detection was developed to measure the concentrations of spectinomycin in fermentation broth. Derivatization reagents, 2,4-dinitrophenylhydrazine in acetonitrile (5 mg mL−1) and trifluoroacetic acid in acetonitrile (0.8 mol L−1), were added to an aliquot of the fermentation broth, and the mixture was incubated for 60 min at 70°C. The resulting derivative was separated from other compounds by isocratic elution in a reversed-phase column Zorbax SB-C18 (250 mm × 4.6 mm, 5 µm). Mobile phase consisted of acetonitrile, tetrahydrofuran, and water (φ r = 40: 35: 25) and the flow rate was 1.0 mL min−1. The detection wavelength was 415 nm. The standard curve for spectinomycin sulfate was linear with correlation coefficients of 0.9997 in the range of 25 µg mL−1 to 600 µg mL−1. The relative standard deviation values ranged from 0.43 % to 2.18 % depending on the concentration of samples. The average recovery was 101.5 %. The limit of detection was 50 ng mL−1.


2012 ◽  
Vol 10 (2) ◽  
pp. 67-70
Author(s):  
Abdullah Al Masud ◽  
Mohammad Saydur Rahman ◽  
Towfika Islam ◽  
Saki Sultana ◽  
Moynul Hasan ◽  
...  

A simple, reproducible and efficient reversed phase high performance liquid chromatographic (RPHPLC) method has been developed for the estimation of a recently approved anti allergic drug, amlexanox in oral paste dosage form. The separations were carried out on a Zorbax Eclipse XBD, C18 column (150 x 4.6 mm; 5?m) at a flow rate of 1.50 ml/min. by using mobile phase comprising of mixed buffer (pH adjusted to 6.50) and methanol (50:50 v/v). The injection volume was 10 ?l and the peaks were detected at 244 nm. The linear dynamic range found to be in the concentration range of 15-35 ?g/ml and coefficient of correlation was found to be 0.999. The %RSD value was below 2.0 for intra-day and inter-day precision which indicated that the method was highly precise. The LOD (Limit of detection) and LOQ (Limit of quantitation) were found to be 3.8 ng/ml and 12.5 ng/ml, respectively which revealed that the method was highly sensitive. The percentage recovery of amlexanox ranged from 99.31 to 99.75%, indicating the accuracy of the method and absence of interference from the excipients present in the formulation. The proposed method was simple, fast, accurate and reproducible and hence can be applied for routine quality control operations of amlexanox in oral paste dosage form. Key words: Amlexanox, Anti allergic, RP-HPLC, LOD, LOQ. DOI: http://dx.doi.org/10.3329/dujps.v10i2.11782 Dhaka Univ. J. Pharm. Sci. 10(2): 67-70, 2011 (December)


2018 ◽  
Vol 9 (2) ◽  
pp. 92-98
Author(s):  
Hassan Ahmad Alhazmi ◽  
Gunasekar Manoharan ◽  
Mohammed Al Bratty ◽  
Sadique Akhtar Javed

A simple isocratic reversed-phase HPLC method for quantification of clobetasone in bulk and cream dosage forms has been developed. Chromatographic analysis was accomplished on an C18 column utilizing a mixture of methanol and water (84:16 v:v, pH = 6.0) as mobile phase. An effluent flow rate of 1 mL/min was adjusted and the detection was made at 240 nm wavelength. The method was evaluated according to ICH guidelines Q2 R1 for linearity, specificity, sensitivity, precision and accuracy. The method exhibited good linearity with correlation coefficient (r2) of 0.9993 over the concentration range from 5 to 50 μg/mL. The recoveries of the test drug from the cream sample was found to be 98.56 to 99.51% and the limit of detection and quantification were calculated as 0.85 and 2.83 μg/mL, respectively, suggesting the accuracy and sensitivity of the developed method. The precision was demonstrated by a low percentage of relative standard deviation (<1%) from six independent assay analysis performed for the cream formulation. Stability indicating property of the proposed method was demonstrated by performing the analysis of forced degradation samples. The developed method can be used for estimation of the clobetasone butyrate in bulk and pharmaceutical formulations for routine analysis in the quality control laboratories.


Author(s):  
M. VIJAYA KUMARI ◽  
CH. BALASEKHAR REDDY

Objective: An accurate, rapid economical and straight forward, reliable assay technique was evolved and showed for the evaluation of zanubrutinib using reversed-phase high-performance liquid chromatography. Methods: In the proposed method, efficient chromatographic separation was achieved applying acetonitrile and 0.1% orthophosphoric acid (50:50 v/v) as a mobile phase with a flow of 1 ml/min and the wavelength was observed at 220 nm. Chromatography was administered isocratically at ambient temperature and run time was approximately 6 min and the retention time (Rt) was observed as 4.358 min. Results: The method was justified as per ICH guidelines. System suitability parameters were studied by injecting the quality six fold and results were well under acceptance criteria. Linearity study was administered between 10% and 150% levels, regression coefficient value was observed as 0.999. Limit of detection and limit of quantification were observed as 0.02 μg/ml and 0.2 μg/ml, respectively. Precision was found to be 0.74 for repeatability and 0.68 for intermediate precision. Recovery of the drug was found to be 98–102%, indicates that the recovery is in the acceptable limit. Validation results were found to be satisfactory and the method applicable for bulk and formulation analysis. Hence, it was evident that the proposed method was said to be suitable for regular analysis and quality control of pharmaceutical preparations. Conclusion: The validation results were in good agreement with the acceptable limit. Relative standard deviation values which are <2.0% indicating the accuracy and precision of this method. Assay of retail formulation was administered and found to be 100.24% was present using the above method. Stress conditions of degradation in acidic, alkaline, peroxide, and thermal were studied. This developed method showed reliable, precise, accurate results under optimized conditions.


2013 ◽  
Vol 781-784 ◽  
pp. 68-71 ◽  
Author(s):  
Fang Tan

A reversed phase HPLC method was developed and validated for analysis of roflumilast, its related substances and degradation products, using Ecosil C18 column (250×4.6 mm, 5 μm) with a flow rate of 1.0 ml/min and detection wavelength of 215nm. The mobile phase was a mixture of acetonitrile and 0.005mol·L-1ammonium dihydrogen phosphate buffer pH 3.5 in the ratio of 48:52 (v/v). The samples were analyzed using 20 μl injection volume and the column temperature was maintained at 30°C. The limit of detection and limit of quantitation were found to be 2.6 ng/ml and 8ng/ml, respectively. The stability-indicating capability of method was established by forced degradation studies and method demonstrated successful separation of drug, its related substances and degradation products. The method is sensitive, specific, accurate, precise and stability indicating for the quantitation of drug, its related substances and other degradation compounds.


Author(s):  
VEERASWAMI B ◽  
NAVEEN VMK

Objective: The present paper describes a simple, accurate, and precise reversed-phase high-performance liquid chromatography (HPLC) method for rapid and simultaneous quantification of dolutegravir (DTG) and rilpivirine (RPV) in bulk and pharmaceutical dosage form and rat plasma. Methods: The chromatographic separation was achieved on Phenomenex C18 (150x4.6mm, 5μm). Mobile phase contained a mixture of 0.1% Ortho phosphoric acid and acetonitrile in the rato of 60:40 v/v, flow rate 1.0ml/min and ultraviolet detection at 262nm. Results: The retention time of DTG and RPV was 4.35 min and 7.73 min, respectively. The proposed method shows a good linearity in the concentration range of 10–150 μg/ml for DTG and 5–75 μg/ml for RPV under optimized conditions. Precision and recovery study results are in between 98 and 102%. In the entire robustness conditions, percentage relative standard deviation is <2.0%. Degradation has minimum effect in stress condition and solutions are stable up to 24 h. DTG and RPV drugs are release 98% at 2 h in rat body. Conclusion: This method is validated for different analytical performance parameters like linearity. Precision, accuracy, limit of detection, limit of quantification, robustness, and pharmacokinetic study were determined according to the International Conference of Harmonization (ICH) Q2B guidelines. All the parameters of validation were found in the acceptance range of ICH guidelines. The same method is also applied for plasma samples study in bioanalytical work.