scholarly journals The First WHO International Standard for Harmonizing the Biological Activity of Bevacizumab

Biomolecules ◽  
2021 ◽  
Vol 11 (11) ◽  
pp. 1610
Author(s):  
Haiyan Jia ◽  
Parvathy Harikumar ◽  
Eleanor Atkinson ◽  
Peter Rigsby ◽  
Meenu Wadhwa

Several Bevacizumab products are approved for clinical use, with many others in late-stage clinical development worldwide. To aid the harmonization of potency assessment across different Bevacizumab products, the first World Health Organization (WHO) International Standard (IS) for Bevacizumab has been developed. Two preparations of a Bevacizumab candidate and comparator were assessed for their ability to neutralize and bind vascular endothelial growth factor (VEGF) using different bioassays and binding assays in an international collaborative study. Relative potency estimates were similar across different assays for the comparator or the duplicate-coded candidate sample. Variability in relative potency estimates was reduced when the candidate standard was used for calculation compared with various in-house reference standards, enabling harmonization in bioactivity evaluations. The results demonstrated that the candidate standard is suitable to serve as an IS for Bevacizumab, with assigned unitages for VEGF neutralization and VEGF binding activity. This standard coded 18/210 was established by the WHO Expert Committee on Biological Standardization, which is intended to support the calibration of secondary standards for product development and lifecycle management. The availability of IS 18/210 will help facilitate the global harmonization of potency evaluation to ensure patient access to Bevacizumab products with consistent safety, quality and efficacy.

1985 ◽  
Vol 53 (01) ◽  
pp. 134-136 ◽  
Author(s):  
P J Gaffney ◽  
A D Curtis

SummaryAn international collaborative study involving seven laboratories was undertaken to assess which of three lyophilised preparations might serve as an International Standard (I.S.) for tissue plasminogen activator (t-PA). Two of the preparations were isolates from human melanoma cell cultures while one was of pig heart origin. A clot lysis assay was used by all participants in the study.The data suggested that both preparations of human cell origin were comparable, in that their log dose-response lines were parallel, while that of the porcine preparation was not. Accelerated degradation studies indicated that one melanoma extract (denoted 83/517) was more stable than the other and it was decided to recommend preparation 83/517 as the standard for t-PA. The International Committee for Thrombosis and Haemostasis (Stockholm 1983) has recommended the use of this material as a standard and it has been established by the Expert Committee on Biological Standardization of the World Health Organization as the International, Standard for tissue plasminogen activator, with an assigned potency of 1000 International Units per ampoule.


Author(s):  
Susan J. Thorpe ◽  
Dawn Sands ◽  
Alan B. Heath ◽  
Malcolm S. Hamilton ◽  
Sheena Blackmore ◽  
...  

AbstractFolate measurements, particularly for whole blood, show wide inter-laboratory and inter-methodology variability. This variability appears to be due in part to the lack of internationally accepted reference materials. A whole blood haemolysate, lyophilised in ampoules and designated 95/528, was therefore evaluated by 15 laboratories in five countries for its suitability as an International Standard (IS) for whole blood folate. The preparation was assayed using a variety of microbiological and protein-binding methodologies against local standards and calibrators. A consensus folate content was assigned to 95/528. The inclusion of three whole blood samples in the study with widely differing folate levels demonstrated a considerable reduction in inter-laboratory variability when the folate content of the samples was determined relative to the proposed IS 95/528 rather than to laboratories' local standards and calibrators. Accelerated degradation studies indicated that the folate content of 95/528 is stable when stored at −20°C. On the basis of the results presented here, the World Health Organization Expert Committee on Biological Standardization established 95/528 as an IS for whole blood folate.


1989 ◽  
Vol 121 (1) ◽  
pp. 157-NP ◽  
Author(s):  
D. Schulster ◽  
R. E. Gaines Das ◽  
S. L. Jeffcoate

ABSTRACT Three ampouled preparations of purified human prolactin were assessed by 20 laboratories in eight countries for their suitability to serve as International Standards for the estimation of human prolactin in serum. Bioassays (pigeon crop sac assays and NB2 cell assays) were carried out in two laboratories, radioreceptor assays by one laboratory and radioimmunoassays by 17 laboratories. By physicochemical analysis the preparations appeared similar. Each preparation contained small amounts of contaminants and/or prolactin variants. No major differences among the three preparations were detected by immunoassay although, in one radioreceptor assay system, one of the preparations was found to differ from the other two. On the basis of all the available information, the Expert Committee on Biological Standardization of the World Health Organization (ECBS) in 1986 established the preparation in ampoules coded 83/562 as the Second International Standard for Prolactin and in October 1988 established the preparation in ampoules coded 84/500 as the Third International Standard for Prolactin. A value of 0·053 IU (53 mIU) prolactin activity/ampoule was assigned to both the Second and Third IS on the basis that this unitage would, insofar as possible, maintain continuity of the IU defined by the First International Reference Preparation of Prolactin, human, for Immunoassay (coded 75/504). Journal of Endocrinology (1989) 121, 157–166


1987 ◽  
Vol 58 (04) ◽  
pp. 1085-1087 ◽  
Author(s):  
P J Gaffney ◽  
A D Curtis

SummaryAn international collaborative study involving ten laboratories located in eight different countries was undertaken in order to replace the current International Standard (I.S.) for tissue plasminogen activator (t-PA). Two lyophilised candidate preparations of high purity were assessed in comparison with the current I.S. for t-PA using only a clot lysis assay. One preparation (coded 861670) was purified from a cultured melanoma cell supernatant and was about 98% single chain t-PA while the other preparation (coded 861624) was derived from Chinese hamster ovary (CHO) cells following DNA recombinant procedures and was 75% single chain t-PA.Both candidate preparations of t-PA compared in quite a satisfactory manner with the current I.S. from the viewpoint of the biometrics of parallel line bioassays and both preparations were quite stable for long periods at low temperatures and stable from up to 1 month at temperatures of 20° and 38° C. Both fultil the criteria to serve as a satisfactory Znd International Standard for t-PA. The Fibrinolysis Subcommittee of the International Committee for Thrombosis and Haemostasis recommended the melanoma source t-PA (861670) as the next I.S. in order to maintain continuity with the 1st I.S. which was also a melanomatype preparation. The data from the ten laboratories indicated that each ampoule of the new proposed standard contains 850 international units of t-PA activity by the clot lysis assay. It is planned to present the results of this study to the Expert Committee on Biological Standardization of the World Health Organization at its next meeting and to request that the preparation of t-PA, coded 861670, be established as the 2ndlnternational Standard for t-PA.


1992 ◽  
Vol 67 (04) ◽  
pp. 424-427 ◽  
Author(s):  
P J Gaffney ◽  
A B Heath ◽  
J W Fenton II

SummarySince 1975 an International Standard for Thrombin of low purity has been used. While this standard was stable and of value for calibrating thrombins of unknown potency the need for a pure a-thrombin standard arose both for accurate calibration and for precise measurement of thrombin inhibitors, notably hirudin. An international collaborative study was undertaken to establish the potency and stability of an ampouled pure a-thrombin preparation. A potency of 97.5 international units (95% confidence limits 86.5-98.5) was established for the new a-thrombin standard (89/ 588) using a clotting-assay procedure. Stability data at various elevated temperatures indicated that the standard could be transported and stored with no significant loss of potency.Ampoules of lyophilised a-thrombin (coded 89/588) have been recommended as an International Standard for a-thrombin with an assigned potency of 100 international units per ampoule by the International Society for Thrombosis and Haemostasis (Thrombin and its Inhibitors Sub-Committee) in Barcelona, Spain in July 1990 while the Expert Committee on Biological Standardisation and Control of the World Health Organisation will consider its status at its next meeting in Geneva in 1991.


1983 ◽  
Vol 50 (03) ◽  
pp. 697-702 ◽  
Author(s):  
T W Barrowcliffe ◽  
A D Curtis ◽  
D P Thomas

SummaryAn international collaborative study was carried out to establish a replacement for the current (2nd) international standard for Factor VIII: C, concentrate. Twenty-six laboratories took part, of which 17 performed one-stage assays, three performed two-stage assays and six used both methods. The proposed new standard, an intermediate purity concentrate, was assayed against the current standard, against a high-purity concentrate and against an International Reference Plasma, coded 80/511, previously calibrated against fresh normal plasma.Assays of the proposed new standard against the current standard gave a mean potency of 3.89 iu/ampoule, with good agreement between laboratories and between one-stage and two- stage assays. There was also no difference between assay methods in the comparison of high-purity and intermediate purity concentrates. In the comparison of the proposed standard with the plasma reference preparation, the overall mean potency was 4.03 iu/ampoule, but there were substantial differences between laboratories, and the two-stage method gave significantly higher results than the one stage method. Of the technical variables in the one-stage method, only the activation time with one reagent appeared to have any influence on the results of this comparison of concentrate against plasma.Accelerated degradation studies showed that the proposed standard is very stable. With the agreement of the participants, the material, in ampoules coded 80/556, has been established by the World Health Organization as the 3rd International Standard for Factor VIII :C, Concentrate, with an assigned potency of 3.9 iu/ampoule.


1985 ◽  
Vol 104 (3) ◽  
pp. 367-379 ◽  
Author(s):  
R. E. Gaines Das ◽  
A. F. Bristow

ABSTRACT Four batches of ampouled materials in ampoules coded 80/558, 81/502, 81/565 and 81/615 were evaluated by 22 laboratories in nine countries in an international collaborative study for their suitability to serve as a replacement for the First International Reference Preparation (IRP) of TSH, Human, for Immunoassay. The ampouled preparations were calibrated by immunoassay and bioassay. The preparation coded 80/558 had satisfactory stability and contained acceptably low levels of contamination with FSH and LH. Estimates of the immunoreactive TSH content of a set of specimens of serum in terms of 80/558 showed agreement in ranking order and no increase in variability compared with estimates made by assay against the First IRP. On the basis of these results, with the agreement of the participants in the study, and with the authorization of the Expert Committee on Biological Standardization of the World Health Organization, the preparation coded 80/558 was established in 1983 as the Second International Reference Preparation of TSH, Human, for Immunoassay, with a defined potency of 37 mi.u./ampoule. Preparations coded 81/502, 81/565 and 81/615 were found suitable to serve as working standards. J. Endocr. (1985) 104, 367–379


2016 ◽  
Vol 54 (9) ◽  
pp. 1467-1472 ◽  
Author(s):  
Susan J. Thorpe ◽  
Peter Rigsby ◽  
Graham Roberts ◽  
Anne Lee ◽  
Malcolm Hamilton ◽  
...  

AbstractBackground:Investigation of possible B12 and folate deficiencies requires measurement of these vitamins in serum. There is evidence that holotranscobalamin (holoTC), the active portion of B12 available to cells, is a more specific marker of early B12 deficiency than total B12. The availability of immunoassays for holoTC prompted an international collaborative study to assign a holoTC value to the World Health Organization (WHO) 1st International Standard (IS) for vitamin B12 and serum folate, 03/178.Methods:The IS, 03/178, and three serum samples with different holoTC levels were assayed by 12 laboratories in eight countries using manual and automated immunoassays for holoTC; one laboratory additionally performed an in-house assay. Fourteen sets of data were analysed.Results:Overall, the IS, 03/178, and the three serum samples demonstrated assay linearity and parallelism. An overall geometric mean (GM) holoTC value of 106.8 pmol/L was obtained for 03/178, with an inter-laboratory geometric coefficient of variation (GCV) of 10.5%. There was a reduction in inter-laboratory variability when the holoTC levels in the serum samples were determined relative to the IS with an assigned holoTC value rather than to the assays’ calibration. Accelerated degradation studies showed that 03/178 was sufficiently stable to serve as an IS for holoTC.Conclusions:The WHO Expert Committee on Biological Standardization endorsed the proposal to assign a holoTC value of 107 pmol/L to 03/178, corresponding to 0.107 pmol per ampoule, for use as the 1st IS for vitamin B12, serum folate, and holoTC.


Sign in / Sign up

Export Citation Format

Share Document