scholarly journals Experimental Studies of Effect of Land Width in PEM Fuel Cells with Serpentine Flow Field and Carbon Cloth

Energies ◽  
2019 ◽  
Vol 12 (3) ◽  
pp. 471 ◽  
Author(s):  
Xuyang Zhang ◽  
Andrew Higier ◽  
Xu Zhang ◽  
Hongtan Liu

Flow field plays an important role in the performance of proton exchange membrane (PEM) fuel cells, such as transporting reactants and removing water products. Therefore, the performance of a PEM fuel cell can be improved by optimizing the flow field dimensions and designs. In this work, single serpentine flow fields with four different land widths are used in PEM fuel cells to study the effects of the land width. The gas diffusion layers are made of carbon cloth. Since different land widths may be most suitable for different reactant flow rates, three different inlet flow rates are studied for all the flow fields with four different land widths. The effects of land width and inlet flow rate on fuel cell performance are studied based on the polarization curves and power densities. Without considering the pumping power, the cell performance always increases with the decrease in the land width and the increase in the inlet flow rates. However, when taking into consideration the pumping power, the net power density reaches the maximum at different combinations of land widths and reactant flow rates at different cell potentials.

2016 ◽  
Vol 30 (16) ◽  
pp. 1650155 ◽  
Author(s):  
Ebrahim Afshari ◽  
Masoud Ziaei-Rad ◽  
Nabi Jahantigh

In PEM fuel cells, during electrochemical generation of electricity more than half of the chemical energy of hydrogen is converted to heat. This heat of reactions, if not exhausted properly, would impair the performance and durability of the cell. In general, large scale PEM fuel cells are cooled by liquid water that circulates through coolant flow channels formed in bipolar plates or in dedicated cooling plates. In this paper, a numerical method has been presented to study cooling and temperature distribution of a polymer membrane fuel cell stack. The heat flux on the cooling plate is variable. A three-dimensional model of fluid flow and heat transfer in cooling plates with 15 cm × 15 cm square area is considered and the performances of four different coolant flow field designs, parallel field and serpentine fields are compared in terms of maximum surface temperature, temperature uniformity and pressure drop characteristics. By comparing the results in two cases, the constant and variable heat flux, it is observed that applying constant heat flux instead of variable heat flux which is actually occurring in the fuel cells is not an accurate assumption. The numerical results indicated that the straight flow field model has temperature uniformity index and almost the same temperature difference with the serpentine models, while its pressure drop is less than all of the serpentine models. Another important advantage of this model is the much easier design and building than the spiral models.


Author(s):  
Michael Pien ◽  
Steven Lis ◽  
Radha Jalan ◽  
Marvin Warshay ◽  
Suresh Pahwa

Higher efficiency operation of PEM fuel cells needs an advanced passive way to remove product water. Water flooding in gas flow channels reduces efficiency and needs to be mitigated by a support of balance of plant design and components which results in parasitic power losses. ElectroChem’s Integrated Flow Field (IFF) design with the integration of hydrophobic and hydrophilic matrix has been proven to solve these challenges with no impact on the performance. The hydrophobic and hydrophilic matrix facilitates two phase (gas and liquid) flow to and away from the interface between the electrode membrane assembly and the flow field. A phase-separation feature of the IFF allowed the fuel cells to operate on a flow rate at its consumption rate. The IFF fuel cell has demonstrated operation at the ideal one stoichiometric ratio with 100% gas utilization and orientation independent. The IFF also served as gas humidifier through the creation of simultaneous distribution of gas and water within the cell. The self-humidification capability keeps the cell operating without the humidity of the input gas. The IFF design also enhanced the performance of water electrolysis which is a reverse process of fuel cell. The IFF supported the passive water feed to the cell and gas separation from the cell.


Author(s):  
Daniel J. Fenton ◽  
Jeffrey J. Gagliardo ◽  
Thomas A. Trabold

To achieve optimal performance of proton exchange membrane (PEM) fuel cells, effective water management is crucial. Cells need to be fabricated to operate over wide ranges of current density and cell temperature. To investigate these design and operational conditions, the present experiment utilized neutron radiography for measurement of in-situ water volumes of operating PEM fuel cells under varying operating conditions. Fuel cell performance was found to be generally inversely correlated to liquid water volume in the active area. High water concentrations restrict narrow flow field channels, limiting the reactant flow, and causing the development of performance-reducing liquid water blockages (slugs). The analysis was performed both quantitatively and qualitatively to compare the overall liquid water volume within the cell to the flow field geometry. The neutron image analysis results revealed interesting trends related to water volume as a function of time. At temperatures greater than 25°C, the total liquid water volume at start-up in the active area was the lowest at 1.5 A/cm2. At 25°C, 0.1 A/cm2 performed with the least amount of liquid water accumulation. However, as the reaction progressed at temperatures above 25°C, there was a crossover point where 0.1 A/cm2 accumulated less water than 1.5 A/cm2. The higher the temperature, the longer the time required to reach this crossover point. Results from the current density analysis showed a minimization of water slugs at 1.5 A/cm2, while the temperature analysis showed unexpectedly that, independent of current density, the condition with lowest water volume was always 35°C.


Author(s):  
S.K. Mahobia

In this paper, we are observed the PEM fuel Cells, which are consist of anode plate, cathode plate, separator, oxygen gases, and hydrogen gases. Separators are used to between the anode plate and cathode plate. The various mass flow rates of oxygen gases and hydrogen gases are obtaining with the help of controlling valve of cylinders. In this way we are achieving the various voltages.


2018 ◽  
Vol 2018 ◽  
pp. 1-13 ◽  
Author(s):  
Saverio Latorrata ◽  
Renato Pelosato ◽  
Paola Gallo Stampino ◽  
Cinzia Cristiani ◽  
Giovanni Dotelli

Polymer electrolyte membrane fuel cells (PEMFCs) have attracted great attention in the last two decades as valuable alternative energy generators because of their high efficiencies and low or null pollutant emissions. In the present work, two gas diffusion electrodes (GDEs) for PEMFCs were prepared by using an ink containing carbon-supported platinum in the catalytic phase which was sprayed onto a carbon cloth substrate. Two aerograph nozzles, with different sizes, were used. The prepared GDEs were assembled into a fuel cell lab prototype with commercial electrolyte and bipolar plates and tested alternately as anode and cathode. Polarization measurements and electrochemical impedance spectroscopy (EIS) were performed on the running hydrogen-fed PEMFC from open circuit voltage to high current density. Experimental impedance spectra were fitted with an equivalent circuit model by using ZView software which allowed to get crucial parameters for the evaluation of fuel cell performance, such as ohmic resistance, charge transfer, and mass transfer resistance, whose trends have been studied as a function of the applied current density.


Energies ◽  
2018 ◽  
Vol 11 (11) ◽  
pp. 3203 ◽  
Author(s):  
Oluwatosin Ijaodola ◽  
Emmanuel Ogungbemi ◽  
Fawwad Nisar. Khatib ◽  
Tabbi Wilberforce ◽  
Mohamad Ramadan ◽  
...  

Environmental concerns of greenhouse gases (GHG) effect from fossil commodities and the fast increase in global energy demand have created awareness on the need to replace fossil fuels with other sources of clean energy. PEM fuel cell (PEMFC) is a promising source of energy to replace fossil fuels. The commercialization of the cell depends on its price, weight and mechanical strength. Bipolar plates are among the main components of PEMFC which perform some significant functions in the fuel cell stack. Metal bipolar plate is considered by the research community as the future material for fuel cells. However, surface coating is required for metals to enhance its corrosion resistance, hydrophilicity and interfacial contact resistance (ICR) in PEM fuel cells. Open pore cellular metal foam (OPCMF) materials have been used to replace the conventional flow field channel in recent times due to its low electrical resistance, high specific area and high porosity; however, it endures the same corrosion problem as the metallic bipolar plate. This investigation offers an overview on different types of bipolar plates and techniques in coating metallic bipolar platse and open pore metal foam as flow field channel materials to improve the corrosion resistance which will eventually increase the efficiency of the fuel cell appreciably.


Electronics ◽  
2020 ◽  
Vol 9 (4) ◽  
pp. 602 ◽  
Author(s):  
Florian Grumm ◽  
Marc Schumann ◽  
Carsten Cosse ◽  
Maik Plenz ◽  
Arno Lücken ◽  
...  

The reduction of greenhouse gas and pollutant emissions is a major issue in modern society. Therefore, environmentally friendly technologies like fuel cells should replace conventional energy generation plants. Today, fuel cells are used in households for CHP (combined heat and power) applications, for emergency power supply in many stationary applications and for the power supply of cars, buses and ships and emergency power supply of aircrafts. A significant challenge is the optimal electrical grid integration and selection of the appropriate grid protection mechanism for fuel cell applications. For this, the short circuit capability and behavior needs to be known. This paper gives a mathematical estimation of the short circuit behavior of fuel cells. Five main transient and dynamic phenomena are investigated. The impact of the main transient effect for the provision of additional short circuit energy is simulated, and the simulation is experimentally validated. For this purpose, a 25 c m 2 single cell consisting of a NafionTM 212 membrane and carbon cloth electrodes with a catalyst loading of 0 . 5 m g / c m 2 Pt is analyzed. The magnitude of the transient short circuit current depends on the operating point right before the short circuit occurs, whereas the stationary short circuit current of fuel cells is invariably about twice the operational current. Based on these results, a novel fuel cell model for the estimation of the short circuit behavior is proposed.


Energies ◽  
2021 ◽  
Vol 14 (9) ◽  
pp. 2687
Author(s):  
Ali A. Hmad ◽  
Nihad Dukhan

A new study investigating the cooling efficacy of air flow inside open-cell metal foam embedded in aluminum models of fuel-cell stacks is described. A model based on a commercial stack was simulated and tested experimentally. This stack has three proton exchange membrane (PEM) fuel cells, each having an active area of 100 cm2, with a total output power of 500 W. The state-of-the-art cooling of this stack employs water in serpentine flow channels. The new design of the current investigation replaces these channels with metal foam and replaces the actual fuel cells with aluminum plates. The constant heat flux on these plates is equivalent to the maximum heat dissipation of the stack. Forced air is employed as the coolant. The aluminum foam used had an open-pore size of 0.65 mm and an after-compression porosity of 60%. Local temperatures in the stack and pumping power were calculated for various air-flow velocities in the range of 0.2–1.5 m/s by numerical simulation and were determined by experiments. This range of air speed corresponds to the Reynolds number based on the hydraulic diameter in the range of 87.6–700.4. Internal and external cells of the stack were investigated. In the simulations, and the thermal energy equations were solved invoking the local thermal non-equilibrium model—a more realistic treatment for airflow in a metal foam. Good agreement between the simulation and experiment was obtained for the local temperatures. As for the pumping power predicted by simulation and obtained experimentally, there was an average difference of about 18.3%. This difference has been attributed to the poor correlation used by the CFD package (ANSYS) for pressure drop in a metal foam. This study points to the viability of employing metal foam for cooling of fuel-cell systems.


2005 ◽  
Vol 2 (4) ◽  
pp. 290-294 ◽  
Author(s):  
Shuo-Jen Lee ◽  
Ching-Han Huang ◽  
Yu-Pang Chen ◽  
Chen-Te Hsu

Aluminum was considered a good candidate material for bipolar plates of the polymer electrolyte membrane (PEM) fuel cells due to its low cost, light weight, high strength and good manufacturability. But there were problems of both chemical and electrochemical corrosions in the PEM fuel cell operating environment. The major goals of this research are to find proper physical vapor deposition (PVD) coating materials which would enhance surface properties by making significant improvements on corrosion resistance and electrical conductivity at a reasonable cost. Several coating materials had been studied to analyze their corrosion resistance improvement. The corrosion rates of all materials were tested in a simulated fuel cell environment. The linear polarization curve of electrochemical method measured by potentiostat instrument was employed to determine the corrosion current. Results of the corrosion tests indicated that all of the coating materials had good corrosion resistance and were stable in the simulated fuel cell environment. The conductivities of the coated layers were better and the resistances changed very little after the corrosion test. At last, single fuel cells were made by each PVD coating material. Fuel cell tests were conducted to determine their performance w.r.t. that was made of graphite. The results of fuel cell tests indicated that metallic bipolar plates with PVD coating could be used in PEM fuel cells.


Author(s):  
Luis Breziner ◽  
Peter Strahs ◽  
Parsaoran Hutapea

The objective of this research is to analyze the effects of vibration on the performance of hydrogen PEM fuel cells. It has been reported that if the liquid water transport across the gas diffusion layer (GDL) changes, so does the overall cell performance. Since many fuel cells operate under a vibrating environment –as in the case of automotive applications, this may influence the liquid water concentration across the GDL at different current densities, affecting the overall fuel cell performance. The problem was developed in two main steps. First, the basis for an analytical model was established using current models for water transport in porous media. Then, a series of experiments were carried, monitoring the performance of the fuel cell for different parameters of oscillation. For sinusoidal vibration at 10, 20 and 50Hz (2 g of magnitude), a decrease in the fuel cell performance by 2.2%, 1.1% and 1.3% was recorded when compared to operation at no vibration respectively. For 5 g of magnitude, the fuel cell reported a drop of 5.8% at 50 Hz, whereas at 20 Hz the performance increased by 1.3%. Although more extensive experimentation is needed to identify a relationship between magnitude and frequency of vibration affecting the performance of the fuel cell as well as a throughout examination of the liquid water formation in the cathode, this study shows that sinusoidal vibration, overall, affects the performance of PEM fuel cells.


Sign in / Sign up

Export Citation Format

Share Document