scholarly journals Transient Stability Analysis of Grid-Connected Converter Driven by Imbalance Power under Non-Severe Remote Voltage Sag

Energies ◽  
2021 ◽  
Vol 14 (6) ◽  
pp. 1737
Author(s):  
Xuli Quan ◽  
Xinchun Lin ◽  
Yun Zheng ◽  
Yong Kang

In the transient process of the grid-connected converter (GCC), the existing research mainly focuses on the impact of the control loops. Little attention is paid to the transient stability issues driven by the imbalance between the input power and output power of GCC. This paper shows that the transient stability issues will still exist even if ignoring the dynamics of phase-locked loop (PLL) and current loop. In this paper, the models of the AC grid and the GCC are built under the assumption that the dynamics of the PLL and current loop are ignored. Then, by analyzing the transient process of GCC under non-severe remote voltage sag, the effects of the imbalance power on the transient stability of GCC are discussed. Moreover, for the GCC to operate stably after the transient process, there should be a maximum input power limit (MIPL) for GCC, and the imbalance power equation is applied in this paper to determine the transient stability of GCC. Furthermore, the effects of the current limitation on the transient stability of the GCC are also discussed. Finally, the theoretical analysis has been verified by means of simulations.

2013 ◽  
Vol 805-806 ◽  
pp. 334-337
Author(s):  
Shi Wei Su ◽  
You Wei Zhou ◽  
Wei Xiong

Analysis compares the direct access to a single set of wind power systemTwo groups of wind farm access system directlyMultiple sets of wind farm access system directly And Multiple sets of wind dispersion access system's impact on power system transient stability. And compare the simulation results, Concluded that wind farm access capacity and its topology structure's influence on system transient stability.


Author(s):  
Mostafa Ahmed ◽  
Mohamed Abdelrahem ◽  
Ahmed Farhan ◽  
Ibrahim Harbi ◽  
Ralph Kennel

AbstractSensorless strategies become very popular in modern control techniques because they increase the system reliability. Besides, they can be used as back-up control in case of sensor failure. In this paper, a DC-link sensorless control approach is developed, which is suited for grid-connected PV systems. The studied system is a two-stage PV scheme, where the DC–DC stage (boost converter) is controlled using an adaptive step-size perturb and observe (P&O) method. Further, the inverter control is accomplished by voltage oriented control (VOC). Generally, the VOC is implemented with two cascaded control loops, namely an outer voltage loop and an inner current loop. However, in this work, the outer loop is avoided and the reference current is generated using a losses model for the system. The losses model accounts for the most significant losses in the PV system. Moreover, particle swarm optimization (PSO) is utilized to compensate for the unmodeled losses. The PSO is executed offline for the purpose of calculation burden reduction. The proposed approach simplifies the cascaded VOC strategy and eliminates the DC-link voltage sensor, which in turn decreases the cost of the system. Finally, the proposed technique is compared with the conventional one at different atmospheric conditions and validated using MATLAB simulation results.


2021 ◽  
Author(s):  
Umme Kulsum Jhuma ◽  
Saad Mekhilef ◽  
Shameem Ahmad ◽  
Jahurul Islam ◽  
Jahidur Rahman Jesan ◽  
...  

2018 ◽  
Vol 10 (11) ◽  
pp. 4140 ◽  
Author(s):  
Seungchan Oh ◽  
Heewon Shin ◽  
Hwanhee Cho ◽  
Byongjun Lee

Efforts to reduce greenhouse gas emissions constitute a worldwide trend. According to this trend, there are many plans in place for the replacement of conventional electric power plants operating using fossil fuels with renewable energy sources (RESs). Owing to current needs to expand the RES penetration in accordance to a new National power system plan, the importance of RESs is increasing. The RES penetration imposes various impacts on the power system, including transient stability. Furthermore, the fact that they are distributed at multiple locations in the power system is also a factor which makes the transient impact analysis of RESs difficult. In this study, the transient impacts attributed to the penetration of RESs are analyzed and compared with the conventional Korean electric power system. To confirm the impact of the penetration of RESs on transient stability, the effect was analyzed based on a single machine equivalent (SIME) configuration. Simulations were conducted in accordance to the Korean power system by considering the anticipated RES penetration in 2030. The impact of RES on transient stability was provided by a change in CCT by increasing of the RES penetration.


Sign in / Sign up

Export Citation Format

Share Document