scholarly journals Heat Transfer and Bearing Characteristics of Energy Piles: Review

Energies ◽  
2021 ◽  
Vol 14 (20) ◽  
pp. 6483
Author(s):  
Jinli Xie ◽  
Yinghong Qin

Energy piles, combined ground source heat pumps (GSHP) with the traditional pile foundation, have the advantages of high heat transfer efficiency, less space occupation and low cost. This paper summarizes the latest research on the heat transfer and bearing capacity of energy piles. It is found that S-shaped tubes have the largest heat transfer area and the best heat transfer efficiency; that energy piles need to be designed conservatively, such as adjusting the safety coefficient, number and spacing of the piles according to the additional temperature loads; and that unbalanced surface temperature has not been resolved, caused by uneven refrigeration/heating demand in one cycle. A composite energy pile applied to water-rich areas is proposed to overcome the decay of bearing and heat transfer performance. Besides, most of the heat transfer models are borehole-oriented and will fit for energy piles effectively if the models support variable ground temperature boundary conditions.

2018 ◽  
Vol 2018 ◽  
pp. 1-12 ◽  
Author(s):  
Qingwen Li ◽  
Lu Chen ◽  
Haotian Ma ◽  
Chung-Ho Huang

The latest research on energy piles demonstrates that most scholars are focusing their attention on optimization by designing more efficient heat exchanger coils, analyzing the heat pump matching parameters, and so on. However, after more than 20 years of development, these traditional methods for improving the heat transfer efficiency of energy piles have reached a bottleneck, and a new approach for the continued enhancement of this technology must be investigated. In this study, powdered graphite with high heat transfer characteristics was included in a concrete mix to create graphite concrete piles with enhanced heat transfer characteristics. The results from theoretical analysis, laboratory testing, and numerical simulation indicate that using graphite to improve the heat transfer efficiency of a concrete material is an effective method for enhancing the thermal efficiency of an energy pile system. The research results also show that the heat transfer coefficient of the concrete exhibits greater improvement when the graphite content is greater than 15% under the same environmental temperature. After studying the performance of the proposed graphite concrete energy pile under different environmental temperatures (10°C, 20°C, 30°C, and 40°C), the results indicate that the working efficiency of the energy pile is better in the summer than in the winter. Finally, parameters such as the cast-in pipe configuration and pile spacing are optimized.


2011 ◽  
Vol 347-353 ◽  
pp. 3798-3803
Author(s):  
Yong Qi Liu ◽  
Xiang Chun Chen

As ceramic oxidation bed has high heat transfer efficiency, now, great attention has been given on it. In the oxidation bed, between the honeycomb holes of the fore-and-aft blocks of ceramic honeycombs, there are dislocation relationships. The effect of dislocation relationship on the pressure drop of the oxidation bed was numerically simulated by Fluent software. The results show that, between the two blocks of closely adjacent ceramic honeycombs, when a gap distance of 1mm was left, compared to the situation the gap distance is 0, the overall resistance loss of the oxidation bed reduced vast.


2020 ◽  
Author(s):  
Lazaros Aresti ◽  
Paul Christodoulides ◽  
Georgios A. Florides

<p>Shallow Geothermal Energy, a Renewable Energy Source, finds application through Ground Source Heat Pumps (GSHPs) for space heating/cooling via tubes directed into the ground. There are two main categories of Ground Heat Exchanger (GHE) types: the horizontal and the vertical types. Ground Heat Exchangers (GHEs) of various configurations, extract or reject heat into the ground. Even though GSHP have higher performance in comparison to the Air Source Heat Pumps (ASHPs), the systems high initial costs and long payback period have made it unattractive as an investment. GSHP systems can also be utilized in the buildings foundation in the form of Thermo-Active Structure (TAS) systems or Energy Geo-Structures (EGS), with applications such as energy piles, barrette piles, diaphragm walls, shallow foundations, retaining walls, embankments, and tunnel linings. Energy piles are reinforced concrete foundations with geothermal pipes, whereby the buildings foundations are utilized to provide space heating and cooling. Apart from energy piles, another EGS system can be achieved by the incorporation of the building’s foundation bed as a GHE. Foundation piles are not required in all constructions, but a building’s foundation bed is mandatory. This configuration is still based on the principles of the energy pile.</p><p>Energy piles have yet to be applied in Cyprus and, thus, a preliminary assessment considered and investigated before application would be useful. The potential of the GSHP systems by utilizing the building’s foundation through energy piles is considered here, for a moderate climate such as Cyprus, towards a Zero Energy Building. Typical foundation piles geometry in Cyprus consists of a 10m depth, a 0.4m diameter and reinforced concrete as a grout material, which is used at the foundation bed of the building. A typical dwelling in Cyprus is selected to be numerically modelled in this study. It is a three-bedroom, two-storey house with a 190m<sup>2</sup> total floor area, matching the thermal characteristics of a Zero Energy Building (i.e., U-values of 0.4W/m<sup>2</sup>/K on all walls and ceiling and 2.25 W/m<sup>2</sup>/K on all doors and windows, respectively). A full-scale model is developed in COMSOL Multiphysics software, to examine the energy rejected or absorbed into the ground by taking the heating and cooling loads of the typical dwelling in Cyprus. The convection-diffusion equation for heat transfer is used with the three-dimensional conservation of heat transfer for an incompressible fluid on all domains except the pipes, where a simplified equation is used. Different months in winter and summer are accounted for the simulations and the fluid-in – fluid-out temperature difference is presented. Finally, an economic evaluation of the systems examined above is presented, in order to check its viability. It is concluded that utilizing the dwelling’s foundations can be a better investment than using GHEs in boreholes.</p>


2014 ◽  
Vol 472 ◽  
pp. 286-290
Author(s):  
Jing Long Du ◽  
Xiang Huang ◽  
Da Wei Tang

The direct steam generation (DSG) with parabolic collector is an attractive option regarding the economic improvement of parabolic technology for solar thermal electricity generation system. On the basis of theory analysis of flow and heat transfer mechanism in the DSG system, this paper presents the numerical simulation results of one 650 meters loop under different direct normal irradiation values, performance parameters such as water temperature, heat transfer coefficient and dryness of the fluid in the absorber pipe are obtained in the simulation results. This paper shows that fluids parameters are susceptible to the solar direct normal values , high heat transfer efficiency and sensitive control system are the key to ensure DSG systems stable operation.


2010 ◽  
Vol 297-301 ◽  
pp. 1199-1204 ◽  
Author(s):  
Seung Moon Baek ◽  
Won Sil Seol ◽  
Ho Saeng Lee ◽  
Jung In Yoon

The heat transfer performance of heat exchanger plate decreases as time goes by. The main reason for this phenomenon is the fouling of the heat exchanger plates. To remove the fouling, we have usually cleaned the plate of heat exchanger using chemicals or polishing brush or cloth with hand after stopping the equipment and disassembling the heat exchanger. However, to clean the plate using these methods, the heat exchanger equipment needs to be stopped and disjointed. In addition, it must be re-jointed after cleaning. Especially, the concern of environmental pollution happens in case of using chemicals. Therefore, we need to develop an automatic fouling removal equipment which can continuously keep high heat transfer efficiency and solve the problem of environmental pollution. So, in this paper, we developed and tested the equipment which can clean the fouling on heat exchanger plates automatically per constant period and interval using air bubbles. The total heat transfer coefficient decreased with a slower tendency when using air bubbles compared to the existing methods. There was 10% higher heat transfer effect air bubbles every 10 minutes for 2 hours to remove the fouling ingredients on the heat transfer surface area concerned to the case without air bubbles after 192 hours.


2012 ◽  
Vol 516-517 ◽  
pp. 408-413 ◽  
Author(s):  
Yue Lian Hu

During recent years,micro-channel heat transfer technique has been successfully used in many practical situations,and has notable advantages of high heat transfer efficiency and compact configuration.It is an important subject in modern hydrodynamic and heat transfer research field.Computational fluid dynamic program CFX will be used in this article to simulate flow and heat transfer of single-phase water in micro-channel ,flow and temperature felid will be described visually in CFX, and this object is searching a new method to research more flow and heat transfer of single-phase water.


2012 ◽  
Vol 424-425 ◽  
pp. 1032-1036
Author(s):  
Zhong Hua Tang ◽  
Mo You Xiong ◽  
De Bao Lei

Through theoretical analysis and experiment, this paper works for studying the heat transfer effect of different types condensers, combined with the advantages and disadvantages of different types of condensers, searching for the condenser which has high heat transfer efficiency and saves energy and water. Based on the experiment, we found that air through the water spray could significantly drop the air enthalpy, and increase the air enthalpy difference when it goes through the condenser. The atomization air could lessen air flow under the condition that the cooling capacity does not change, and that the compressor working pressure and fan power also would be reduced. This evaporative condensers compare with others saves much more water, reduces the coil fouling and equipment corrosion, and can improve the work reliability of the condenser


Author(s):  
Toshihiko Shakouchi ◽  
Yusuke Matsumoto ◽  
Koichi Tsujimoto ◽  
Toshitake Ando

Abstract Heat exchangers are used widely in many fields, and various kinds of exchanger have been developed according to the requirement of the practical applications. Recently, heat exchangers that are highly efficient or compact have become more desirable from the viewpoint of energy conservation, and several new types have been developed, such as a compact fin tube type and a double tube type having an inner pipe with a special geometry. In this study, the flow and heat transfer characteristics of a petal-shaped double tube with a large wetted perimeter of six and five petals and five shallow petals and the effect of tube shape on the heat transfer and heat transfer efficiency were examined experimentally. The heat transfer of the double tube with a petal-shaped inner tube was increased because of the large wetted perimeter, but the pressure loss by friction increased. The optimal shape of the petal-shaped double tube with a high heat transfer performance and the greatest efficiency is discussed.


Sign in / Sign up

Export Citation Format

Share Document