scholarly journals New Analytical Approach for the Determination of Calcium Phosphate Dibasic and Tribasic in Processed Food by Comparison of Ion Chromatography with High-Performance Liquid Chromatography

Foods ◽  
2020 ◽  
Vol 9 (3) ◽  
pp. 248 ◽  
Author(s):  
Minjung Song ◽  
Juhee Park ◽  
Jihyun Lee ◽  
Heejae Suh ◽  
Hyunjung Lee ◽  
...  

An analytical method to measure solubilized orthophosphate ions (HPO42− and PO43− ) from the water-insoluble food additives calcium phosphate dibasic (DCP) and calcium phosphate tribasic (TCP) in processed foods was optimized by comparing ion chromatography (IC) coupled with DS6 conductivity detector (Cond.) and high-performance liquid chromatography (HPLC) with Evaporative light scattering detector (ELSD) methods. The ion-pairing HPLC method could analyze calcium and phosphate ions successively. However, this method exhibited low reproducibility after approximately 48 hours of measurements. The IC method was established as an effective method of measuring orthophosphate ions with high reproducibility using distilled water and KOH solution as the mobile phase with a Dionex column. Matrix-based limit of detections (LOD) and limit of quantifications (LOQ) for snacks and cereals were estimated in the range of 0.01–0.91 µg/mL and 0.21–2.74 µg/mL, respectively. In inter-day and intra-day tests, the calculated precision (%RSD) and accuracy (recovery %) ranged from 0.5% to 6.6% and 82% to 117%, respectively, in both food samples. The levels of DCP or TCP could be analyzed in various positive food samples, and the developed IC method demonstrated good applicability in the analysis of DCP and TCP in collected processed foods.

2011 ◽  
Vol 140 ◽  
pp. 302-308 ◽  
Author(s):  
Zhong Ling Wu ◽  
Zhong Qiang He ◽  
Mao Zhang Guo

The HPLC method has been developed for the determination of nine food additives (acesulfame-potassium, benzoic acid, sodium saccharin, sorbic acid, dehydroacetic acid, aspartame, methylparaben, ethylparaben, propylparaben) in condiments. Samples were precipitated , tested by the reverse-phase high performance liquid chromatography instrument with photodiode array detector . All the compounds exhibited good linear relationship with the correlation coefficient from 0.9991 to 0.9998. The recoveries were range from 87.1% to 108.5 % with the RSD values from 1.61 % to 5.13 % at the spiked levels from 5 mg/kg to 250 mg/kg. The detection limits of the method were from 0.3 mg/kg to 2.0 mg/kg. It is a convenient, accurate and effective method to determine these additives in condiment.


2020 ◽  
Vol 20 (13) ◽  
pp. 1053-1059
Author(s):  
Mahmoud M. Sebaiy ◽  
Noha I. Ziedan

Background: Allergic diseases are considered as the major burden on public health with increased prevalence globally. Histamine H1-receptor antagonists are the foremost commonly used drugs in the treatment of allergic disorders. The target drug in this study, loratadine, belongs to this class of drugs and its biometabolite desloratadine which is also a non-sedating H1 receptor antagonist with anti-histaminic activity being 2.5 to 4 times greater than loratadine. This study aimed to develop and validate a novel isocratic Reversed-phase High-Performance Liquid Chromatography (RP-HPLC) method for rapid and simultaneous separation and determination of loratadine and its metabolite, desloratadine in human plasma. Methods: The drug extraction method from plasma was based on protein precipitation technique. The separation was carried out on a Thermo Scientific BDS Hypersil C18 column (5μm, 250 x 4.60 mm) in a mobile phase of MeOH: 0.025M KH2PO4 adjusted to pH 3.50 using orthophosphoric acid (85: 15, v/v) at an ambient temperature. The flow rate was maintained at 1 mL/min and maximum absorption was measured using the PDA detector at 248 nm. Results: The retention times of loratadine and desloratadine in plasma samples were recorded to be 4.10 and 5.08 minutes, respectively, indicating a short analysis time. Limits of detection were found to be 1.80 and 1.97 ng/mL for loratadine and desloratadine, respectively, showing a high degree of sensitivity of the method. The method was then validated according to FDA guidelines for the determination of the two analytes in human plasma. Conclusion: The results obtained indicate that the proposed method is rapid, sensitive in the nanogram range, accurate, selective, robust and reproducible compared to other reported methods.


1986 ◽  
Vol 49 (5) ◽  
pp. 383-388 ◽  
Author(s):  
PETER SPORNS ◽  
SUET KWAN ◽  
LAWRENCE A. ROTH

Oxytetracycline (OTC), also known commercially as Terramycin, was determined to be more stable in honey than in buffered aqueous solutions at similar pH values and temperatures. A rapid high performance liquid chromatography (HPLC) method was developed to detect and quantitate OTC using a 1:1 dilution (wt/wt) of honey samples in water. Using 355 nm as the wavelength of detection, amounts as low as 0.5 μg/ml could be detected in the above solution. The limits of detection were lowered considerably by a double extraction procedure.


2006 ◽  
Vol 89 (6) ◽  
pp. 1552-1556
Author(s):  
ArmaĞan Önal ◽  
Olcay SaĞiri ◽  
S Müge Çetin ◽  
Sidika Toker

Abstract Reboxetine is used as a selective noradrenaline reuptake inhibitor for the treatment of major depressive disorders. It is effective in the treatment of severe depression and safer to use than traditional tricyclic antidepressants. In this study, a novel, simple, and rapid stability-indicating high-performance liquid chromatography (HPLC) method for reboxetine methansulfonate was successfully developed and validated for the assay of tablets. The method was used to quantify reboxetine in tablets; it employed a C18 column (150 4.6 mm id) with an isocratic mobile phase consisting of methanolphosphate buffer (pH 7, 0.02 M; 55 + 45, v/v) at a flow rate of 1.0 μmL/min. Reboxetine was detected by an ultraviolet detector at 277 nm. The retention time of reboxetine was about 4.5 min. The developed HPLC method was validated with respect to linearity, precision, sensitivity, accuracy, and selectivity. The method was linear over the concentration range 150 g/mL (r 0.9999). The limits of detection and the quantitation of reboxetine were 0.1 and 0.3 μg/mL, respectively. The relative standard deviation values for intraday and interday precision were 0.781.01 and 1.081.37%, respectively. Selectivity was validated by subjecting a stock solution of reboxetine to neutral, acid, and alkali hydrolysis, as well as oxidation, dry heat treatment, and photodegradation. The peaks of the degradation products did not interfere with the peak of reboxetine. The results indicated that the proposed method could be used in a stability assay. The proposed method was successfully applied to the determination of reboxetine in tablets. Excipients present in the tablets did not interfere with the analysis.


2020 ◽  
Vol 103 (3) ◽  
pp. 779-783
Author(s):  
Özlem Aksu Dönmez ◽  
Şule Dinç-Zor ◽  
Bürge Aşçı ◽  
Abdürrezzak E Bozdoğan

Abstract Background In many countries, the levels of synthetic food additives causing harm to humans have been determined and their use has been controlled by legal regulations. Sensitive, accurate and low-cost analysis methods are required for food additive determination. Objective In this study, a fast high performance liquid chromatography-diode array detection (HPLC-DAD) analytical methodology for quantification of sodium benzoate, potassium sorbate, ponceau 4R, and carmoisine in a beverage was proposed. Methods Partial least squares (PLS) and principal component regression (PCR) multivariate calibration methods applied to chromatograms with overlapped peaks were used to establish a green and smart method with short isocratic elution. A series of synthetic solutions including different concentrations of analytes were used to test the prediction ability of the developed methods. Conclusions The average recoveries for all target analytes were in the range of 98.27–101.37% with average relative prediction errors of less than 3%. The proposed chemometrics-assisted HPLC-DAD methods were implemented to a beverage successfully. Analysis results from sodium benzoate, potassium sorbate, ponceau 4R, and carmoisine in a beverage by PLS-2 and PCR were statistically compared with conventional HPLC. Highlights The HPLC methods coupled with the PLS-2 and PCR algorithm could provide a simple, quick and accurate strategy for simultaneous determination of sodium benzoate, potassium sorbate, ponceau 4R, and carmoisine in a beverage sample.


2021 ◽  
Vol 0 (0) ◽  
Author(s):  
Katso Binang ◽  
David T. Takuwa

Abstract The aim of the study was to develop a rapid, efficient, and cheap chromatographic method for determining four selected antihypertensive active flavonoid compounds in medicinal plants in Botswana. The determination of rutin, quercetin, and kaempferol in selected medicinal plants was conducted in less than 6 min using the developed reverse phase-high performance liquid chromatography (RP-HPLC) method with a 2.7 µm Ascentis C18 express column (150 × 4.60 mm i.d) at 340, 360, and 368 nm detection wavelengths and mobile phase of methanol and 0.068% of formic acid solution in isocratic elution. Validation results showed good selectivity, linearity (r 2 > 0.99), high percentage recoveries (90.2–104.7%), and precision (% RSD < 2) for n = 3, confirming suitability of the method for determination of the investigated flavonoids in Zingiber officinale (ginger). Application of the developed RP-HPLC method was performed in selected medicinal plants (Lippia javanica ) (mosukujane), Myrothanmus flabellious (galalatshwene), and Elephantorrhiza elephantina (mositsana) used to manage hypertension by herbalists in Botswana. M. flabellious a very commonly used plant for managing hypertension was found to contain highest amounts of rutin and myricetin, whereas nothing was detected for E. elephantina.


2021 ◽  
pp. 1-11
Author(s):  
Sultan M. Alshahrani ◽  
John Mark Christensen

This study was designed to develop and validate a simple and efficient high performance liquid chromatography (HPLC) method to determine flunixin concentrations in Asian elephant’s (Elephas maximus) plasma. Flunixin was administered orally at a dose of 0.8 mg/kg, and blood samples were collected. Flunixin extraction was performed by adding an equal amount of acetonitrile to plasma and centrifuging at 4500 rpm for 25 minutes. The supernatant was removed, and flunixin was analyzed using HPLC-UV detection. Two methods were developed and tested utilizing two different mobile phases either with or without adding methanol (ACN: H2O vs. ACN: H2O: MeOH). Both methods showed excellent linearity and reproducibility. The limit of detection was 0.05 ug/ml and limit of quantification was 0.1 ug/ml. the efficiency of flunixin recovery was maximized by the addition of methanol to mobile phase (ACN: H2O: MeOH as 50:30:20) at 95% in comparison to 23% without methanol. In conclusion, adding methanol to HPLC methods for extraction of flunixin from elephants’ plasma yielded higher recovery rate than without methanol.


Author(s):  
Yan Xiong ◽  
Yong-Hong Liu ◽  
Jian-Sha Li ◽  
Yu-Ying Zhang ◽  
Jing Zhang ◽  
...  

Abstract A simple high performance liquid chromatography (HPLC) method was developed and validated for the determination of coumarin-3-carboxylic acid analogues (C3AA) in rat plasma and a preliminary study on pharmacokinetics. Ferulic acid (FA) was used as the internal standard substance, and coumarin-3-carboxylic acid (C3A) was used as a substitute for quantitative C3AA. After protein precipitation with methanol, the satisfactory separation was achieved on an ODS2 column when the temperature was maintained at 30 ± 2°C. The correlation coefficient r in the C3A linear equation is equal to 0.9990. Pharmacokinetic parameters for t1/2, Tmax, Cmax, area under the curve (AUC)0-t, average residence time (MRT), apparent volume of distribution (V z/F) and clearance (Cl/F) were 1.89 ± 0.03 h, 0.39 ± 0.14 h, 1.81 ± 0.10 g· mL−1 ·h, 7.88 ± 0.24 g·mL−1·h, 3.23 ± 0.14 h, 0.43 ± 0.03 (mg·kg−1)·(g·mL−1)−1·h−1, respectively. The high performance liquid chromatography-photo diode array detector (HPLC-PDA) method established in this study can be used to separate and determine the content of C3AA in plasma of rats after 60% ethanol extraction by gavage. The plasma concentration-time curve and pharmacokinetic parameters reflect the absorption of C3AA in rat blood after oral administration to some extent.


INDIAN DRUGS ◽  
2017 ◽  
Vol 54 (01) ◽  
pp. 35-40
Author(s):  
A. S. Bagde ◽  
V. V. Khanvilkar ◽  

The present work describes a validated reverse phase high performance liquid chromatography (RPHPLC) method for simultaneous estimation of dextromethorphan hydrobromide and quinidine sulphate in pharmaceutical dosage from. The drugs were resolved using Hemochrom Intsil C18-5U column (250×4.6) mm in isocratic mode with mobile phase methanol: water (0.08% diethylamine, 0.02% of glacial acetic acid and pH 4.4 adjusted with orthophosphoric acid) in the ratio of 70:30 V/V at a flow rate of 1.0 mL/min. Retention time of dextromethorphan hydrobromide and quinidine sulphate were 4.9±0.2 and 3.6±0.2, respectively, at 292nm. The above mentioned method was validated as per International Conference on Harmonization (ICH) guidelines. Linear responses were obtained in concentration ranges of 5-35 μg/mL for dextromethorphan hydrobromide and 4-16 μg/mL for quinidine sulphate, with correlation coefficient (r2) of 0.999 for both the drugs. A simple, selective, accurate, precise, robust and reliable RP-HPLC method thus developed and validated for simultaneous estimation of dextromethorphan hydrobromide and quinidine sulphate.