scholarly journals Association between Body Fat and Elevated Blood Pressure among Children and Adolescents Aged 7–17 Years: Using Dual-Energy X-ray Absorptiometry (DEXA) and Bioelectrical Impedance Analysis (BIA) from a Cross-Sectional Study in China

Author(s):  
Manman Chen ◽  
Jieyu Liu ◽  
Ying Ma ◽  
Yanhui Li ◽  
Di Gao ◽  
...  

To investigate the associations between body fat percentage (BF%) with childhood blood pressure (BP) levels and elevated BP (EBP) risks, and further examine the validity of bioelectrical impedance analysis (BIA), we conducted a cross-sectional study of 1426 children and adolescents aged 7–17 years in Beijing, 2020. EBP, including elevated systolic BP (ESBP) and elevated diastolic BP (EDBP), was defined based on the age- and sex-specific 90th BP reference values of children and adolescents in China. BF% was measured by dual-energy X-ray absorptiometry (DEXA) and BIA devices, and was divided into four quartiles. Log-binomial models were applied to calculate odds ratios (ORs) and 95% confidence intervals (95%CI). Girls tended to have higher BF% levels than boys (p < 0.05). There was 41.0% of girls who developed EBP. High BF% was associated with increased BP levels with ORs of 0.364 (95%CI = 0.283–0.444) for SBP, 0.112 (95%CI = 0.059–0.165) for DBP, and 1.043 (95%CI = 1.027–1.059) for EBP, while the effects were more pronounced in girls and older-aged children. BIA devices agreed well with BF% assessment obtained by DEXA. High BF% might have negative effects on childhood BP. Convenient measurements of body fat might help to assess childhood obesity and potential risks of hypertension.

BMJ Open ◽  
2020 ◽  
Vol 10 (7) ◽  
pp. e036335
Author(s):  
Bo Gao ◽  
Yu Liu ◽  
Chao Ding ◽  
Shunli Liu ◽  
Xiaotian Chen ◽  
...  

ObjectivesBioelectrical impedance analysis (BIA) is a simple and inexpensive method to estimate body composition. However, the accuracy of BIA is unknown. We aimed to assess the accuracy of BIA in estimating visceral fat area (VFA) in patients with gastric cancer.Study designThis was a cross-sectional study comparing the accuracy of BIA in estimating VFA with the gold standard method measured by CT. VFA was measured in enrolled patients both by CT and BIA. VFA by CT at umbilical level ≥100 cm2 was considered as visceral obesity. Reliability between the two methods was assessed by intraclass correlation coefficient (ICC) and consistency was assessed by Bland-Altman method (95% limits of agreement). The area under the receiver operating characteristic curve (AUROC) was used to assess the performance of BIA in diagnosing visceral obesity.SettingThe study was conducted in China.ParticipantsFrom 1 January 2017 to 1 December 2018, a total of 157 patients diagnosed with gastric cancer were enrolled.ResultsOverall, VFA by CT and BIA in patients was 84.39±46.43 cm2 and 71.94±22.44 cm2, respectively. VFA estimated by BIA was positively correlated with VFA measured by CT using Pearson’s test (r=0.650, p<0.001). Overall, ICC for the two methods was 0.675. The mean bias between the two measurements was 12.45±36.13 cm2. The 95% limits of agreement ranged from −58.36 cm2 to 83.26 cm2. The cut-off value for diagnosing visceral obesity by BIA was 81 cm2 (AUROC: 0.822, p<0.001, 95% CI 0.758 to 0.887).ConclusionsVFA measured by BIA showed satisfactory reliability with that measured by CT. However, the absolute values of the two methods were not interchangeable. The cut-off value for VFA by BIA in diagnosing visceral obesity was 81 cm2 for patients with gastric cancer in the Chinese population.


Sign in / Sign up

Export Citation Format

Share Document