scholarly journals Evaluation of Multiple Methods for Quantification of Glycosaminoglycan Biomarkers in Newborn Dried Blood Spots from Patients with Severe and Attenuated Mucopolysaccharidosis-I

2020 ◽  
Vol 6 (3) ◽  
pp. 69 ◽  
Author(s):  
Zackary M. Herbst ◽  
Leslie Urdaneta ◽  
Terri Klein ◽  
Maria Fuller ◽  
Michael H. Gelb

All newborn screening (NBS) for mucopolysaccharidosis-I (MPS-I) is carried out by the measurement of α-iduronidase (IDUA) enzymatic activity in dried blood spots (DBS). The majority of low enzyme results are due to pseudodeficiencies, and studies from the Mayo Clinic have shown that the false positive rate can be greatly reduced by including a second-tier analysis of glycosaminoglycans (GAGs) in DBS as part of NBS. In the present study, we obtained newborn DBS from 13 patients with severe MPS-I and 2 with attenuated phenotypes. These samples were submitted to four different GAG mass spectrometry analyses in a comparative study: (1) internal disaccharide; (2) endogenous disaccharide; (3) Sensi-Pro; (4) Sensi-Pro Lite (a variation of Sensi-Pro with a simplified workflow). Patients with attenuated MPS-I show less GAG elevation than those with severe disease, and all MPS-I patients were separated from the reference range using all four methods. The minimal differential factor (lowest GAG marker level in MPS-I samples divided by highest level in the reference range of 30 random newborns) was about two for internal disaccharide, Sensi-Pro, and Sensi-Pro Lite methods. The endogenous disaccharide was clearly the best method with a minimal differential of 16-fold. This study supports use of second-tier GAG analysis of newborn DBS, especially the endogenous disaccharide method, as part of NBS to reduce the false positive rate.

2012 ◽  
Vol 413 (15-16) ◽  
pp. 1306-1307
Author(s):  
Julie Brossaud ◽  
Pascal Barat ◽  
Laurence Fagour ◽  
Jean-Benoît Corcuff

2010 ◽  
Vol 56 (11) ◽  
pp. 1686-1695 ◽  
Author(s):  
Coleman T Turgeon ◽  
Mark J Magera ◽  
Carla D Cuthbert ◽  
Perry R Loken ◽  
Dimitar K Gavrilov ◽  
...  

BACKGROUND Newborn screening (NBS) for inborn errors of propionate, methionine, and cobalamin metabolism relies on finding abnormal concentrations of methionine and propionylcarnitine. These analytes are not specific for these conditions and lead to frequent false-positive results. More specific markers are total homocysteine (tHCY), methylmalonic acid (MMA), and methylcitric acid (MCA), but these markers are not detected by current NBS methods. To improve this situation, we developed a method for the detection of tHCY, MMA, and MCA in dried blood spots (DBSs) by liquid chromatography–tandem mass spectrometry (LC-MS/MS). METHODS The analytes were extracted from a single 4.8-mm DBS punch with acetonitrile:water:formic acid (59:41:0.42) containing dithiothreitol and isotopically labeled standards (d3-MMA, d3-MCA, d8-homocystine). The extract was dried and treated with 3 N HCl in n-butanol to form butylesters. After evaporation of the butanol, the residue was reconstituted and centrifuged and the supernatant was subjected to LC-MS/MS analysis. Algorithms were developed to apply this method as an efficient and effective second-tier assay on samples with abnormal results by primary screening. RESULTS The 99th percentiles determined from the analysis of 200 control DBSs for MMA, MCA, and HCY were 1.5, 0.5, and 9.8 μmol/L, respectively. Since 2005, prospective application of this second-tier analysis to 2.3% of all NBS samples led to the identification of 13 affected infants. CONCLUSIONS Application of this assay reduced the false-positive rate and improved the positive predictive value of NBS for conditions associated with abnormal propionylcarnitine and methionine concentrations.


2020 ◽  
Vol 6 (1) ◽  
pp. 10 ◽  
Author(s):  
Dawn S. Peck ◽  
Jean M. Lacey ◽  
Amy L. White ◽  
Gisele Pino ◽  
April L. Studinski ◽  
...  

Enzyme-based newborn screening for Mucopolysaccharidosis type I (MPS I) has a high false-positive rate due to the prevalence of pseudodeficiency alleles, often resulting in unnecessary and costly follow up. The glycosaminoglycans (GAGs), dermatan sulfate (DS) and heparan sulfate (HS) are both substrates for α-l-iduronidase (IDUA). These GAGs are elevated in patients with MPS I and have been shown to be promising biomarkers for both primary and second-tier testing. Since February 2016, we have measured DS and HS in 1213 specimens submitted on infants at risk for MPS I based on newborn screening. Molecular correlation was available for 157 of the tested cases. Samples from infants with MPS I confirmed by IDUA molecular analysis all had significantly elevated levels of DS and HS compared to those with confirmed pseudodeficiency and/or heterozygosity. Analysis of our testing population and correlation with molecular results identified few discrepant outcomes and uncovered no evidence of false-negative cases. We have demonstrated that blood spot GAGs analysis accurately discriminates between patients with confirmed MPS I and false-positive cases due to pseudodeficiency or heterozygosity and increases the specificity of newborn screening for MPS I.


2017 ◽  
Vol 242 (5) ◽  
pp. 547-553
Author(s):  
Huiying Hu ◽  
Yulin Jiang ◽  
Minghui Zhang ◽  
Shanying Liu ◽  
Na Hao ◽  
...  

To evaluate, side by side, the efficiency of dried blood spots (DBSs) against serum screening for Down’s syndrome, and then, to construct a two-tier strategy by topping up the fetal cell-free DNA (cfDNA) secondary screening over the high-risk women marked by the primary blood testing to build a practical screening tactic to identify fetal Down’s syndrome. One thousand eight hundred and thirty-seven low-risk Chinese women, with singleton pregnancy, were enrolled for the study. Alpha-fetoprotein and free beta human chorionic gonadotropin were measured for the serum as well as for the parallel DBS samples. Partial high-risk pregnant women identified by primary blood testing (n = 38) were also subject to the secondary cfDNA screening. Diagnostic amniocentesis was utilized to confirm the screening results. The true positive rate for Down’s syndrome detection was 100% for both blood screening methods; however, the false-positive rate was 3.0% for DBS and 4.0% for serum screening, respectively. DBS correlated well with serum screening on Down’s syndrome detection. Three out of 38 primary high-risk women displayed chromosomal abnormalities by cfDNA analysis, which were confirmed by amniocentesis. Either the true detection rate or the false-positive rate for Down’s syndrome between DBS and the serum test is comparable. In addition, blood primary screening aligned with secondary cfDNA analysis, a “before and after” two-tier screening strategy, can massively decrease the false-positive rate, which, then, dramatically reduces the demand for invasive diagnostic operation. Impact statement Children born with Down’s syndrome display a wide range of mental and physical disability. Currently, there is no effective treatment to ease the burden and anxiety of the Down’s syndrome family and the surrounding society. This study is to evaluate the efficiency of dried blood spots against serum screening for Down’s syndrome and to construct a two-tier strategy by topping up the fetal cell-free DNA (cfDNA) secondary screening over the high-risk women marked by the primary blood testing to build a practical screening tactic to identify fetal Down’s syndrome. Results demonstrate that fetal cfDNA can significantly reduce false-positive rate close to none while distinguishing all true positives. Thus, we recommend that fetal cfDNA analysis to be utilized as a secondary screening tool atop of the primary blood protein screening to further minimize the capacity of undesirable invasive diagnostic operations.


2021 ◽  
Vol 9 ◽  
Author(s):  
Wei Zhou ◽  
Heng Cai ◽  
Huizhong Li ◽  
Zhe Ji ◽  
Maosheng Gu

Background: Although newborn screening (NBS) for metabolic defects using the marker butyl carnitine (C4) combined with the C4-to-acetylcarnitine ratio is adequate, the incorporation of novel parameters may improve differential testing for these disorders without compromising sensitivity.Methods: Analytical and clinical performance was evaluated by MS/MS using 237 initially positive neonatal samples between March 2019 and March 2020 at the Newborn Screening Center of Xuzhou Maternity and Child Health Care Hospital. Additionally, second-tier testing by ultraperformance liquid chromatography-tandem mass spectrometry (UPLC-MS/MS) combined with the quantification of ethylmalonate (EMA) or isobutyryl-glycine (IBG) in dried blood spots (DBSs) was performed to reduce the false-positive rate.Results: We reviewed initial MS/MS data for DBSs from 469,730 neonates, and a second-tier test was performed using 237 samples that exceeded the C4 concentration cutoff value. Eleven variants of the ACADS gene were identified, with c.1031A>G (p.E344G) being the most common. Fifteen ACAD8 mutations were identified in seven patients, and Swiss modeling and amino acid conservation analyses were conducted for the novel variants. Based on a retrospective analysis of EMA and IBG, the application of second-tier tests before the release of neonatal screening results reduced referrals by over 91.89% and improved the positive predictive value (PPV) for short-chain acyl-CoA dehydrogenase deficiency/isobutyryl-CoA dehydrogenase deficiency (SCADD/IBDD) screening.Conclusion: A screening algorithm including EMA/IBG improves target differential testing for NBS and may eliminate unnecessary referrals while maintaining 100% sensitivity. Second-tier screening using UPLC-MS/MS as a rapid and convenient supplemental DNA sequencing method may be beneficial for differential detection.


2021 ◽  
Author(s):  
Wei Zhou ◽  
Jinxiu Song ◽  
Huizhong Li ◽  
Zhe Ji ◽  
Xin Yin ◽  
...  

Abstract Background: An improved second-tier test is needed to reduce the false-positive rate of newborn screening (NBS) for inborn metabolic disorders in Xuzhou, China.Methods: We designed an expanded second-tier assay using newborn dried blood spots (DBSs). Analytical and clinical performance were evaluated in 53 newborns with methylmalonic acidemia (MMA) or propionic acidemia (PA) reported by the Xuzhou Maternity and Child Health Care Hospital NBS program. Additionally, we analyzed NBS data regarding seasonal variation of metabolites, birth weight and gestational age to improve the identification of true positive MMA/PA individuals.Results: Among the 53 MMA/PA individuals assessed, two pathogenic or likely pathogenic (P/LP) variants in an MMA/PA-associated gene were identified in 46 patients, and a pathogenic variant and a variant of unknown significance (VUS) were identified in 7 patients. No such variants were detected in MMA/PA false-positive individuals or healthy controls. Ultraperformance liquid chromatography-tandem mass spectrometry (UPLC-MS/MS)-based analysis of the initial NBS metabolic profile correctly identified MMA/PA individuals and reduced the initial NBS false-positive rate by 98.86%. MMA/PA false-positive infants in Xuzhou, China, were most likely to be summer-born.Conclusion: We established a two-pronged approach to reduce false positives by nearly 99% and provided a novel NBS strategy. Challenges in neonate metabolic testing and DNA variant interpretation regarding season, birth weight and pregnancy status remain for this Chinese population.


2002 ◽  
Vol 41 (01) ◽  
pp. 37-41 ◽  
Author(s):  
S. Shung-Shung ◽  
S. Yu-Chien ◽  
Y. Mei-Due ◽  
W. Hwei-Chung ◽  
A. Kao

Summary Aim: Even with careful observation, the overall false-positive rate of laparotomy remains 10-15% when acute appendicitis was suspected. Therefore, the clinical efficacy of Tc-99m HMPAO labeled leukocyte (TC-WBC) scan for the diagnosis of acute appendicitis in patients presenting with atypical clinical findings is assessed. Patients and Methods: Eighty patients presenting with acute abdominal pain and possible acute appendicitis but atypical findings were included in this study. After intravenous injection of TC-WBC, serial anterior abdominal/pelvic images at 30, 60, 120 and 240 min with 800k counts were obtained with a gamma camera. Any abnormal localization of radioactivity in the right lower quadrant of the abdomen, equal to or greater than bone marrow activity, was considered as a positive scan. Results: 36 out of 49 patients showing positive TC-WBC scans received appendectomy. They all proved to have positive pathological findings. Five positive TC-WBC were not related to acute appendicitis, because of other pathological lesions. Eight patients were not operated and clinical follow-up after one month revealed no acute abdominal condition. Three of 31 patients with negative TC-WBC scans received appendectomy. They also presented positive pathological findings. The remaining 28 patients did not receive operations and revealed no evidence of appendicitis after at least one month of follow-up. The overall sensitivity, specificity, accuracy, positive and negative predictive values for TC-WBC scan to diagnose acute appendicitis were 92, 78, 86, 82, and 90%, respectively. Conclusion: TC-WBC scan provides a rapid and highly accurate method for the diagnosis of acute appendicitis in patients with equivocal clinical examination. It proved useful in reducing the false-positive rate of laparotomy and shortens the time necessary for clinical observation.


1993 ◽  
Vol 32 (02) ◽  
pp. 175-179 ◽  
Author(s):  
B. Brambati ◽  
T. Chard ◽  
J. G. Grudzinskas ◽  
M. C. M. Macintosh

Abstract:The analysis of the clinical efficiency of a biochemical parameter in the prediction of chromosome anomalies is described, using a database of 475 cases including 30 abnormalities. A comparison was made of two different approaches to the statistical analysis: the use of Gaussian frequency distributions and likelihood ratios, and logistic regression. Both methods computed that for a 5% false-positive rate approximately 60% of anomalies are detected on the basis of maternal age and serum PAPP-A. The logistic regression analysis is appropriate where the outcome variable (chromosome anomaly) is binary and the detection rates refer to the original data only. The likelihood ratio method is used to predict the outcome in the general population. The latter method depends on the data or some transformation of the data fitting a known frequency distribution (Gaussian in this case). The precision of the predicted detection rates is limited by the small sample of abnormals (30 cases). Varying the means and standard deviations (to the limits of their 95% confidence intervals) of the fitted log Gaussian distributions resulted in a detection rate varying between 42% and 79% for a 5% false-positive rate. Thus, although the likelihood ratio method is potentially the better method in determining the usefulness of a test in the general population, larger numbers of abnormal cases are required to stabilise the means and standard deviations of the fitted log Gaussian distributions.


Sign in / Sign up

Export Citation Format

Share Document