scholarly journals Diagnostic Yield of Transabdominal Ultrasonography for Evaluation of Pancreatic Cystic Lesions Compared with Endoscopic Ultrasonography

2021 ◽  
Vol 10 (19) ◽  
pp. 4616
Author(s):  
Yu Ji Li ◽  
Gil Ho Lee ◽  
Min Jae Yang ◽  
Jae Chul Hwang ◽  
Byung Moo Yoo ◽  
...  

Detection rates of pancreatic cystic lesions (PCLs) have increased, resulting in greater requirements for regular monitoring using imaging modalities. We aimed to evaluate the capability of ultrasonography (US) for morphological characterization of PCLs as a reference standard using endoscopic ultrasonography (EUS). A retrospective analysis was conducted of 102 PCLs from 92 patients who underwent US immediately prior to EUS between January 2014 and May 2017. The intermodality reliability and agreement of the PCL morphologic findings of the two techniques were analyzed and compared using the intraclass correlation coefficient and κ values. The success rates of US for delineating PCLs in the head, body, and tail of the pancreas were 77.8%, 91.8%, and 70.6%, respectively. The intraclass correlation coefficient for US and the corresponding EUS lesion size showed very good reliability (0.978; p < 0.001). The κ value between modalities was 0.882 for pancreatic duct dilation, indicating good agreement. The κ values for solid components and cystic wall and septal thickening were 0.481 and 0.395, respectively, indicating moderate agreement. US may be useful for monitoring PCL growth and changes in pancreatic duct dilation, but it has limited use in the diagnosis and surveillance of mural nodules or cystic wall thickness changes.

2003 ◽  
Vol 93 (3) ◽  
pp. 185-189 ◽  
Author(s):  
Hazel Noakes ◽  
Craig Payne

Several decisions need to be made when prescribing foot orthoses for abnormal foot pronation. One of these decisions is how much force is needed from orthoses to supinate the foot. The supination resistance test has been described as one technique to help determine the amount of force needed. The aim of this project was to determine the reliability of the manual supination resistance test. Four clinicians of differing levels of experience performed the test on 44 subjects (88 feet) on 2 separate days. The test had good reliability overall, with an intertester intraclass correlation coefficient of 0.89. For the two more experienced clinicians, the intratester intraclass correlation coefficients were good (0.82 and 0.78), but for the two inexperienced clinicians they were poor (0.56 and 0.62). The supination resistance test may be clinically useful in the prescription of foot orthoses, but more work is needed to determine its validity and its relationship to clinical outcomes. (J Am Podiatr Med Assoc 93(3): 185-189, 2003)


2018 ◽  
Vol 27 (5) ◽  
Author(s):  
Kelsey Picha ◽  
Carolina Quintana ◽  
Amanda Glueck ◽  
Matt Hoch ◽  
Nicholas R. Heebner ◽  
...  

Context: Reaction time (RT) is crucial to athletic performance. Therefore, when returning athletes to play following injury, it is important to evaluate RT characteristics ensuring a safe return. The Dynavision D2® system may be utilized as an assessment and rehabilitation aid in the determination of RT under various levels of cognitive load. Previous research has demonstrated good reliability of simple protocols when assessed following a 24- to 48-hour test–retest window. Expanding reliable test–retest intervals may further refine novel RT protocols for use as a diagnostic and rehabilitation tool. Objective: To investigate the test–retest reliability of a battery of 5 novel RT protocols at different time intervals. Design: Repeated measures/reliability. Setting: Interdisciplinary sports medicine research laboratory. Participants: Thirty healthy individuals. Methods: Participants completed a battery of protocols increasing in difficulty in terms of reaction speed requirement and cognitive load. Prior to testing, participants were provided 3 familiarization trials. All protocols required participants to hit as many lights as quickly as possible in 60 seconds. After completing the initial testing session (session 1), participants waited 1 hour before completing the second session (session 2). Approximately 2 weeks later (average 14 [4] d), the participants completed the same battery of tasks for the third session (session 3). Main Outcome Measures: The intraclass correlation coefficient, standard error of measurement, minimal detectable change, and repeated-measures analysis of variance were calculated for RT. Results: The intraclass correlation coefficient values for each of the 5 protocols illustrated good to excellent reliability between sessions 1, 2, and 3 (.75–.90). There were no significant differences across time points (F < 0.105, P > .05). Conclusions: The 1-hour and 14-day test–retest intervals are reliable for clinical assessment, expanding the time frames previously reported in the literature of when assessments can be completed reliably. This study provides novel protocols that challenge cognition in unique ways.


2019 ◽  
Vol 30 (6) ◽  
pp. 1287-1294
Author(s):  
Nermin Serbecic ◽  
Sven Beutelspacher ◽  
Lovro Markovic ◽  
Abhijit Sina Roy ◽  
Rohit Shetty

Introduction: The aim of this study was to evaluate repeatability and reproducibility of newly calculated biomechanical parameters of the cornea, developed by our research group. Methods: One eye from each of the 23 healthy subjects was measured three times consecutively, three times at different daytimes and on three different days. The within-subject standard deviation and coefficient of variation, as well as the intraclass correlation coefficient, were calculated for every parameter in each group. Results: Excellent repeatability and reproducibility (coefficient of variation < 5%, intraclass correlation coefficient > 0.75) was found for corrected values measured at A1, HC, and A2 time points (2nd A2 Time, 2nd A1 Time, 2nd HC Time, 2nd HC Def Amp and 2nd A1 Def Amp). Corneal-specific stiffness parameters, which showed good repeatability and reliability, were DA_cor (coefficient of variation = 4.02%, intraclass correlation coefficient = 0.919), KcLinear (coefficient of variation = 4.03%, intraclass correlation coefficient = 0.895), areaForceCornea (coefficient of variation = 3.34%, intraclass correlation coefficient = 0.853) and E2 (coefficient of variation = 4.1%, intraclass correlation coefficient = 0.78). Overall, most parameters fell into the category of good reliability (high intraclass correlation coefficient) and poor reproducibility (low coefficient of variation), including all the parameters describing extraocular deformation (DA_ext, AEPvED, AUC EDef, areaForceExtra, Kg and μg). Comparing the coefficient of variation values for intrasession, intersession and daytime measurements, there were no indices for diurnal changes. Conclusion: Most parameters showed good repeatability and reliability. The extraocular stiffness parameters showed poor reproducibility. KcLinear can serve as a very reliable and repeatable indicator of corneal stiffness.


2017 ◽  
Vol 60 (1) ◽  
pp. 191-198 ◽  
Author(s):  
Santiago Valladares-Rodríguez ◽  
Ezequiel Rey ◽  
Marcos Mecías-Calvo ◽  
Roberto Barcala-Furelos ◽  
Antonio J. Bores-Cerezal

Abstract The purpose of this study was to determine the reliability and usefulness of the 30-15 Intermittent Fitness Test (30-15IFT) in professional male and female futsal players. Thirteen male (24.4 ± 5.6 years; 174.5 ± 10.3 cm; 70.3 ± 9.9 kg) and fourteen female (23.3 ± 4.5 years; 165.8 ± 6.2 cm; 61.7 ± 5.5 kg) professional futsal players performed the 30-15IFT on two occasions, separated by 5 days. Maximal intermittent running velocity (VIFT) and heart rate at exhaustion (HRpeak) data were collected for both tests. Reliability was assessed by the intraclass correlation coefficient (ICC), typical error (TE) expressed as a coefficient of variation (CV), and smallest worthwhile change (SWC). VIFT demonstrated very good reliability between sessions, both for male (ICC = 0.92) and female (ICC = 0.96) players. As the TE for VIFT and HRpeak was similar to the calculated SWC for both male and female players, the usefulness of the test was rated as “medium”. A change in performance of at least 2 stages in male players, or a change of more than 1 stage in female players could be interpreted as a meaningful change in aerobic futsal fitness. The results of this study demonstrate that the 30-15IFT is both a reliable and useful test for male and female professional futsal players.


2016 ◽  
Vol 2016 ◽  
pp. 1-6
Author(s):  
Bo Zhang ◽  
Jianjun Gu ◽  
Xiaoxiao Zhang ◽  
Bin Yang ◽  
Zheng Wang ◽  
...  

Purpose. To explore the probability and variation in biomechanical measurements of rabbit cornea by a modified Scheimpflug device.Methods. A modified Scheimpflug device was developed by imaging anterior segment of the model imitating the intact eye at various posterior pressures. The eight isolated rabbit corneas were mounted on the Barron artificial chamber and images of the anterior segment were taken at posterior pressures of 15, 30, 45, 60, and 75 mmHg by the device. The repeatability and reliability of the parameters including CCT, ACD, ACV, and CV were evaluated at each posterior pressure. All the variations of the parameters at the different posterior pressures were calculated.Results. All parameters showed good intraobserver reliability (Cronbach’s alpha; intraclass correlation coefficient,α, ICC > 0.96) and repeatability in the modified Scheimpflug device. With the increase of posterior pressures, the ratio of CCT decreased linearly and the bulk modulus gradually reduced to a platform. The increase of ACD was almost linear with the posterior pressures elevated.Conclusions. The modified Scheimpflug device was a valuable tool to investigate the biomechanics of the cornea. The posterior pressure 15–75 mmHg range produced small viscoelastic deformations and nearly linear pressure-deformation response in the rabbit cornea.


2020 ◽  
Vol 10 (1) ◽  
Author(s):  
Lloyd Roberts ◽  
Tom Rozen ◽  
Deirdre Murphy ◽  
Adam Lawler ◽  
Mark Fitzgerald ◽  
...  

Abstract Background Multiple screening Duplex ultrasound scans (DUS) are performed in trauma patients at high risk of deep vein thrombosis (DVT) in the intensive care unit (ICU). Intensive care physician performed compression ultrasound (IP-CUS) has shown promise as a diagnostic test for DVT in a non-trauma setting. Whether IP-CUS can be used as a screening test in trauma patients is unknown. Our study aimed to assess the agreement between IP-CUS and vascular sonographer performed DUS for proximal lower extremity deep vein thrombosis (PLEDVT) screening in high-risk trauma patients in ICU. Methods A prospective observational study was conducted at the ICU of Alfred Hospital, a major trauma center in Melbourne, Australia, between Feb and Nov 2015. All adult major trauma patients admitted with high risk for DVT were eligible for inclusion. IP-CUS was performed immediately before or after DUS for PLEDVT screening. The paired studies were repeated twice weekly until the DVT diagnosis, death or ICU discharge. Written informed consent from the patient, or person responsible, or procedural authorisation, was obtained. The individuals performing the scans were blinded to the others’ results. The agreement analysis was performed using Cohen’s Kappa statistics and intraclass correlation coefficient for repeated binary measurements. Results During the study period, 117 patients had 193 pairs of scans, and 45 (39%) patients had more than one pair of scans. The median age (IQR) was 47 (28–68) years with 77% males, mean (SD) injury severity score 27.5 (9.53), and a median (IQR) ICU length of stay 7 (3.2–11.6) days. There were 16 cases (13.6%) of PLEDVT with an incidence rate of 2.6 (1.6–4.2) cases per 100 patient-days in ICU. The overall agreement was 96.7% (95% CI 94.15–99.33). The Cohen’s Kappa between the IP-CUS and DUS was 0.77 (95% CI 0.59–0.95), and the intraclass correlation coefficient for repeated binary measures was 0.75 (95% CI 0.67–0.81). Conclusions There is a substantial agreement between IP-CUS and DUS for PLEDVT screening in trauma patients in ICU with high risk for DVT. Large multicentre studies are needed to confirm this finding.


Author(s):  
Daniela Claessens ◽  
Alexander K. Schuster ◽  
Ronald V. Krüger ◽  
Marian Liegl ◽  
Laila Singh ◽  
...  

AbstractIn this study, the test-retest-reliability as one aspect of reliability of metamorphopsia measurements using a computer-based measuring method was determined in patients with macular diseases. Metamorphopsia amplitude, position, and area were quantified using AMD – A Metamorphopsia Detector software (app4eyes GmbH & Co. KG, Germany) in patients with diabetic, myopic, or uveitic macular edema, intermediate or neovascular age-associated macular degeneration, epiretinal membrane, vitelliform maculopathy, Irvine-Gass syndrome, or macular edema due to venous retinal occlusion. The intraclass correlation coefficient (ICC) was calculated in order to determine the repeatability of two repeated measurements and was used as an indicator of the reliability of the measurements. In this study, metamorphopsia measurements were conducted on 36 eyes with macular diseases. Metamorphopsia measurements made using AMD – A Metamorphopsia Detector software were highly reliable and repeatable in patients with maculopathies. The intraclass correlation coefficient of all indices was excellent (0.95 – 0.97). For diseases of the vitreoretinal interface or macular diseases with intra- or subretinal edema, this metamorphopsia measurement represents a supplement for visual function testing in the clinic, as well as in clinical studies.


Sign in / Sign up

Export Citation Format

Share Document