scholarly journals Universal Adhesive for Fixed Retainer Bonding: In Vitro Evaluation and Randomized Clinical Trial

Materials ◽  
2021 ◽  
Vol 14 (6) ◽  
pp. 1341
Author(s):  
Maria Francesca Sfondrini ◽  
Simone Gallo ◽  
Benedetta Turcato ◽  
Mona A. Montasser ◽  
Nehal Fouad Albelasy ◽  
...  

This study aims to assess the efficacy of a universal adhesive (Scotchbond Universal, 3M ESPE) (SB) in total-etch mode, compared to a traditional orthodontic primer (Transbond XT Primer, 3M ESPE) (XT Primer), to perform bonding of orthodontic fixed retainers along with the Transbond XT Light Cure Adhesive Paste (3M ESPE). For the in vitro study, a round section wire (Ortosmail Krugg) was bonded using XT Primer for 20 bovine incisors (Group 1) and SB for other 20 (Group 2). Samples were debonded in a universal testing machine applying a tangential force to specimens (crosshead speed of 1 millimeter per minute). Shear bond strength (SBS) and adhesive remnant index (ARI) scores were calculated. For the in vivo study, 100 patients needing upper and lower canine-to-canine fixed retainers after orthodontic treatment were randomly assigned to two groups of 50 participants each, i.e., group 1 (retainer bonding with XT Primer) and group 2 (retainer bonding with SB). Over two years, examinations were carried out monthly, and detachments were registered by considering the teeth and arches affected. In vitro, no statistically significant differences in SBS and ARI scores were demonstrated between the two groups, both showing a mean bond strength of about 12 MPa and major frequency of ARI “2” (>50% remnant adhesive on the enamel). Conversely, a significantly lower failure rate over 2 years was assessed clinically for group 2 in both arches. Independently of the adhesive and arch, incisors reported a significantly higher failure rate than canines. Scotchbond Universal used in total-etch mode could be a valid alternative to the traditional orthodontic Transbond XT Primer.

2017 ◽  
Vol 22 (1) ◽  
pp. 82-88 ◽  
Author(s):  
Jéssika Lagni Tonus ◽  
Fernanda Borguetti Manfroi ◽  
Gilberto Antonio Borges ◽  
Eduardo Correa Grigolo ◽  
Sérgio Helegda ◽  
...  

ABSTRACT Introduction: Material biodegradation that occurs in the mouth may interfere in the bonding strength between the bracket and the enamel, causing lower bond strength values in vivo, in comparison with in vitro studies. Objective: To develop a prototype to measure bracket debonding force in vivo and to evaluate, in vitro, the bond strength obtained with the prototype. Methods: A original plier (3M Unitek) was modified by adding one strain gauge directly connected to its claw. An electronic circuit performed the reading of the strain gauge, and the software installed in a computer recorded the values of the bracket debonding force, in kgf. Orthodontic brackets were bonded to the facial surface of 30 bovine incisors with adhesive materials. In Group 1 (n = 15), debonding was carried out with the prototype, while tensile bond strength testing was performed in Group 2 (n = 15). A universal testing machine was used for the second group. The adhesive remnant index (ARI) was recorded. Results: According to Student’s t test (α = 0.05), Group 1 (2.96 MPa) and Group 2 (3.08 MPa) were not significantly different. ARI score of 3 was predominant in the two groups. Conclusion: The prototype proved to be reliable for obtaining in vivo bond strength values for orthodontic brackets.


2021 ◽  
Vol 2021 ◽  
pp. 1-6
Author(s):  
Zohreh Moradi ◽  
Farnoosh Akbari ◽  
Sara Valizadeh

Aim. This study aimed to assess shear bond strength (SBS) of resin cement to zirconia ceramic with different surface treatments by using Single Bond Universal. Methods. In this in vitro study, 50 zirconia discs (2 × 6 mm) were divided into 5 groups of (I) sandblasting with silica-coated alumina (CoJet)  + silane + Single Bond 2, (II) sandblasting with CoJet + Single Bond Universal, (III) sandblasting with alumina + Single Bond Universal, (IV) sandblasting with alumina + Z-Prime Plus, and (V) Single Bond Universal with no surface treatment. Resin cement was applied in plastic tubes (3 × 5 mm2), and after 10,000 thermal cycles, the SBS was measured by a universal testing machine. The mode of failure was determined under a stereomicroscope at × 40 magnification. Data were analyzed using one-way ANOVA. Results. The maximum (6.56 ± 4.29 MPa) and minimum (1.94 ± 1.96 MPa) SBS values were noted in groups III and I, respectively. Group III had the highest frequency of mixed failure (60%). Group V had the maximum frequency of adhesive failure (100%). Conclusion. Single Bond Universal + sandblasting with alumina or silica-coated alumina particles is an acceptable method to provide a strong SBS between resin cement and zirconia.


2007 ◽  
Vol 77 (4) ◽  
pp. 701-706 ◽  
Author(s):  
Rodney G. Northrup ◽  
David W. Berzins ◽  
Thomas Gerard Bradley ◽  
William Schuckit

Abstract Objective: To evaluate and compare the shear bond strengths of two adhesives using two types of brackets: a conventional and a self-ligating bracket system. Materials and Methods: Sixty extracted human premolars were collected. The premolars were randomly divided into three groups of 20 teeth. All three groups were direct bonded. Groups 1 and 2 used light-cured adhesive and primer (Transbond XT) with a conventional (Orthos) and a self-ligating bracket (Damon 2), respectively. Group 3 used a light-cured primer (Orthosolo) and a light-cured adhesive (Blūgloo) with a self-ligating bracket (Damon 2). The specimens were stored in distilled water at 37°C for 40 ± 2 hours, after which they were debonded and inspected for Adhesive Remnant Index (ARI) scoring. Results: The mean shear bond strength was 15.2 MPa for group 1, 23.2 MPa for group 2, and 24.8 MPa for group 3. A one-way analysis of variance and post hoc Tukey test showed significant differences in bond strength (P < .001) between group 1 and groups 2 and 3 but no significant difference (P > .05) between groups 2 and 3. A Weibull analysis demonstrated that all three groups provided sufficient bond strength with over 90% survival rate at normal masticatory and orthodontic force levels. A Kruskal-Wallis test showed no significant difference (P > .05) in ARI scores among all three groups. Conclusions: All three groups demonstrated clinically acceptable bond strength. The Damon 2 self-ligating bracket exhibited satisfactory in vitro bond strength with both adhesive systems used.


2017 ◽  
Vol 22 (4) ◽  
pp. 47-52 ◽  
Author(s):  
Marina Cumerlato ◽  
Eduardo Martinelli de Lima ◽  
Leandro Berni Osorio ◽  
Eduardo Gonçalves Mota ◽  
Luciane Macedo de Menezes ◽  
...  

ABSTRACT Objective: The aim of this in vitro study was to evaluate and compare the effects of grinding, drilling, sandblasting, and ageing prefabricated teeth (PfT) on the shear bond strength (SBS) of orthodontic brackets, as well as the effects of surface treatments on the adhesive remnant index (ARI). Methods: One-hundred-ninety-two PfT were divided into four groups (n = 48): Group 1, no surface treatment was done; Group 2, grinding was performed with a cylindrical diamond bur; Group 3, two drillings were done with a spherical diamond bur; Group 4, sandblasting was performed with 50-µm aluminum oxide. Before the experiment, half of the samples stayed immersed in distilled water at 37oC for 90 days. Brackets were bonded with Transbond XT and shear strength tests were carried out using a universal testing machine. SBS were compared by surface treatment and by ageing with two-way ANOVA, followed by Tukey’s test. ARI scores were compared between surface treatments with Kruskal-Wallis test followed by Dunn’s test. Results: Surface treatments on PfT enhanced SBS of brackets (p< 0.01), result not observed with ageing (p= 0.45). Groups II, III, and IV showed higher SBS and greater ARI than the Group 1 (p< 0.05). SBS was greater in the groups 3 and 4 (drilling, sandblasting) than in the Group 2 (grinding) (p< 0.05). SBS and ARI showed a positive correlation (Spearman’s R2= 0.57; p< 0.05). Conclusion: Surface treatment on PfT enhanced SBS of brackets, however ageing did not show any relevance. Sandblasting and drilling showed greater SBS than grinding. There was a positive correlation between SBS and ARI.


2016 ◽  
Vol 2016 ◽  
pp. 1-10 ◽  
Author(s):  
Andreas Hellak ◽  
Jennifer Ebeling ◽  
Michael Schauseil ◽  
Steffen Stein ◽  
Matthias Roggendorf ◽  
...  

Objective.The aim of this in vitro study was to determine the shear bond strength (SBS) and adhesive remnant index (ARI) score of two self-etching no-mix adhesives (iBond™and Scotchbond™) on different prosthetic surfaces and enamel, in comparison with the commonly used total etch system Transbond XT™.Materials and Methods. A total of 270 surfaces (1 enamel and 8 restorative surfaces,n=30) were randomly divided into three adhesive groups. In group 1 (control) brackets were bonded with Transbond XT primer. In the experimental groups iBond adhesive (group 2) and Scotchbond Universal adhesive (group 3) were used. The SBS was measured using a Zwicki 1120™testing machine. The ARI and SBS were compared statistically using the Kruskal–Wallis test (P≤0.05).Results. Significant differences in SBS and ARI were found between the control group and experimental groups.Conclusions. Transbond XT showed the highest SBS on human enamel. Scotchbond Universal on average provides the best bonding on all other types of surface (metal, composite, and porcelain), with no need for additional primers. It might therefore be helpful for simplifying bonding in orthodontic procedures on restorative materials in patients. If metal brackets have to be bonded to a metal surface, the use of a dual-curing resin is recommended.


2015 ◽  
Vol 5 (2) ◽  
pp. 65-68
Author(s):  
Shruti Patil ◽  
Prajna Shetty

ABSTRACT Background The dentin desensitizers available for in-office application for prevention and/or treatment of post restorative dentinal hypersensitivity, act by blocking the open dentinal tubules. In doing so, they may influence the bond strength of the restorative resins. Thus, the aim of the study was to evaluate the effect of desensitizers on the shear bond strength of dentin adhesives and to check the extent of dentinal tubule occlusion caused by these desensitizers. Materials and Methods Sixty-four premolars were randomly divided into four groups of sixteen each. The middle depth dentin was exposed by on the buccal surface and was etched using 37% phosphoric acid and rinsed. They were assigned to, Group 1: Gluma desensitizer, Group 2: Vivasens desensitizer, Group 3: Gluma Comfort Bond and desensitizer, and Group 4: Adper Single Bond 2. Composite resin post of 2 mm in height and width were built on these specimens. The samples were then mounted in acrylic resin blocks. Universal testing machine was used to test the shear bond strength. The data were analyzed using one-way analysis of variance (ANOVA) and post hoc Tukey's test. Results The mean values of the shear bond strength were for: Group 1—18.61 ± 1.03 MPa, Group 2—17.53 ± 1.36 MPa, Group 3—22.63 ± 1.61 MPa and Group 4—23.12 ± 1.02 MPa. There was a statistically significant difference (p < 0.05) among the groups. Conclusion The use of dentin desensitizers’ influences bond strength between the tooth and the adhesive. Among the various agents, the single bottle system containing Gluma comfort bond and desensitizer had the best adhesion among the desensitizer groups. How to cite this article Patil S, Naik B, Shetty P. A Comparative Evaluation of Three Commercially Available Dentin Desensitizers on the Shear Bond Strength of Composite Resins: An in vitro Study. J Contemp Dent 2015;5(2):65-68.


2013 ◽  
Vol 14 (6) ◽  
pp. 1036-1038
Author(s):  
Abdul Mujeeb ◽  
Bhadra Rao ◽  
Satti Narayana Reddy ◽  
Kanchan Mehta ◽  
G Saritha

ABSTRACT Aim To determine the shear bond strength of self-etch adhesive G-bond on pre-etched enamel. Materials and methods Thirty caries free human mandibular premolars extracted for orthodontic purpose were used for the study. Occlusal surfaces of all the teeth were flattened with diamond bur and a silicon carbide paper was used for surface smoothening. The thirty samples were randomly grouped into three groups. Three different etch systems were used for the composite build up: group 1 (G-bond self-etch adhesive system), group 2 (G-bond) and group 3 (Adper single bond). Light cured was applied for 10 seconds with a LED unit for composite buildup on the occlusal surface of each tooth with 8 millimeters (mm) in diameter and 3 mm in thickness. The specimens in each group were tested in shear mode using a knife-edge testing apparatus in a universal testing machine across head speed of 1 mm/ minute. Shear bond strength values in Mpa were calculated from the peak load at failure divided by the specimen surface area. The mean shear bond strength of all the groups were calculated and statistical analysis was carried out using one-way Analysis of Variance (ANOVA). Results The mean bond strength of group 1 is 15.5 Mpa, group 2 is 19.5 Mpa and group 3 is 20.1 Mpa. Statistical analysis was carried out between the groups using one-way ANOVA. Group 1 showed statistically significant lower bond strength when compared to groups 2 and 3. No statistical significant difference between groups 2 and 3 (p < 0.05). Conclusion Self-etch adhesive G-bond showed increase in shear bond strength on pre-etched enamel. How to cite this article Rao B, Reddy SN, Mujeeb A, Mehta K, Saritha G. An Evaluation of Shear Bond Strength of Self-Etch Adhesive on Pre-etched Enamel: An In vitro Study. J Contemp Dent Pract 2013;14(6):1036-1038.


2017 ◽  
Vol 16 ◽  
pp. 1-7
Author(s):  
Bruna Lorena dos Santos Oliveira ◽  
Ana Rosa Costa ◽  
Américo Bortolazzo Correr ◽  
Marcus Vinicius Crepaldi ◽  
Lourenço Correr-Sobrinho ◽  
...  

Aim: To evaluate, in vitro, the effect of adhesive and bonding materials on the shear bond strength (SBS) of metallic brackets bonded to bovine teeth. Methods: Bovine teeth were embedded with acrylic resin, etched with 35% phosphoric acid for 20 s, rinsed, dried for 20 s and divided into 8 groups (n=20), according to the bonding materials and adhesive: Groups 1 and 5 – Transbond XT; Groups 2 and 6 – Fill Magic; Groups 3 and 7 – Biofix; and, Groups 4 and 8 – Orthocem. One layer of adhesive 3 M Unitek (Group 1), and one layer of Single Bond Universal Adhesive (Groups 2, 3 and 4) were applied and light-cured with LED for 10 s. Brackets were bonded to the buccal surface with four bonding materials and light-cured with LED for 40 s. SBS was carried out after 24 h and thermocycling (7,000 cycles - 5°/55 °C). Data were submitted to two way ANOVA and Tukey’s post hoc test (α=0.05). The Adhesive Remaining Index (ARI) was evaluated at 8×. Results: The adhesive was effective in increasing the SBS for all bonding materials (p<0.05). Significant difference (p<0.05) on the SBS was observed between bonding materials with or without adhesive. The ARI showed a predominance of scores 0 for all groups. Conclusions: The adhesive improved significantly the SBS of the brackets to teeth. Different SBS values occurred among the bonding materials. ARI index showed predominance of score 0 for all groups.


2013 ◽  
Vol 01 (01) ◽  
pp. 009-014
Author(s):  
Suruchi Chaudhary Tayal ◽  
Jaidev Dhillon ◽  
Abhishek Tayal

Abstract Introduction: The management of dentinal hypersensitivity involves remineralization by various means, one of which being CPP-ACP paste, followed by restoration. It was speculated that the bond strength of self-etching adhesive was affected following the application of CPP-ACP paste and prior etching with phosphoric acid. Aims and objectives: To evaluate the tensile bond strength (TBS) of G-Bond (GB, self-etching adhesive) to dentin following the application of CPP-ACP (Tooth Mousse/TM), with and without prior etching. Materials and method: Freshly extracted forty five permanent molars were collected for the study. All the teeth were ground and polished to expose the flat dentinal surface. The teeth were embedded in the resin in separate molds and were divided into three equal groups of fifteen samples each Group 1: Samples treated with Tooth Mousse for 60 min daily for 7 days and then restored with GB and composite (Filtek Z350, 3M ESPE). Group 2: Samples treated with Tooth Mousse and etched with phosphoric acid prior to restoration with GB and composite. Group3: Samples restored with GB and composite. A split brass mold was placed over the predesigned location and with help of the plasma coated instrument, composite resin was placed. Tensile loading was done using Universal Testing Machine. Conclusion: TBS of GB was not significantly reduced after CPP-ACP application, but after prior etching the CPP-ACP specimens, the bond strength of GB was significantly reduced.


Author(s):  
Masoud Fallahinejad Ghajari ◽  
Amir Ghasemi ◽  
Mohammadreza Badiee ◽  
Zahra Abdolazimi ◽  
Alireza Akbarzadeh Baghban

Objectives: This study aimed to assess the microshear bond strength (MSBS) of Scotchbond Universal adhesive, used in self-etch and etch-and-rinse modes, to primary and permanent dentin at 24 hours and six months. Materials and Methods: A total of 88 composite micro-cylinders were divided into eight groups (n=11) as follows: (A) Etch-and-rinse, 24 hours, primary dentin; (B) Self-etch, 24 hours, primary dentin; (C) Etch-and-rinse, six months, primary dentin; (D) Self-etch, six months, primary dentin; (E) Etch-and-rinse, 24 hours, permanent dentin; (F) Self-etch, 24 hours, permanent dentin; (G) Etch-and-rinse, six months, permanent dentin; (H) Self-etch, six months, permanent dentin. The MSBS was measured by a testing machine at a crosshead speed of 0.5 mm/minute. Data were analyzed using three-way analysis of variance (ANOVA). Results: The mean MSBS was 12.3±2.3 MPa in A, 18.8±4.1 MPa in B, 11.9±3.7 MPa in C, 16±2.9 MPa in D, 19.1±2.7 MPa in E, 22.8±4.1 MPa in F, 16.2±2.6 MPa in G, and 17.2±4.4 MPa in H. In the self-etch mode, the MSBS was significantly higher than that in the etch-and-rinse mode (P<0.001). The MSBS in permanent teeth was significantly higher than primary teeth (P<0.001). At six months, the MSBS significantly decreased in all groups (P<0.001). Conclusion: The micro-shear bond strength of Scotchbond Universal adhesive decreases over time and depends on the type of tooth and the mode of application of the adhesive.


Sign in / Sign up

Export Citation Format

Share Document