scholarly journals Contrast-Enhanced Ultrasound for Assessing Abdominal Conditions in Pregnancy

Medicina ◽  
2020 ◽  
Vol 56 (12) ◽  
pp. 675
Author(s):  
Thomas Geyer ◽  
Johannes Rübenthaler ◽  
Matthias F. Froelich ◽  
Laura Sabel ◽  
Constantin Marschner ◽  
...  

Background and objectives: Native ultrasound is the most common imaging modality in obstetrics. The use of contrast-enhanced ultrasound (CEUS) during pregnancy has not been officially approved by leading societies for obstetrics and ultrasound. The present study aims to monitor the safety and diagnostic performance of CEUS for assessing abdominal issues in five pregnant women. Materials and Methods: Five pregnant patients who underwent a total of 11 CEUS examinations between June 2020 and October 2020 were included (mean age: 34 years; mean time of pregnancy: 21 weeks). All CEUS scans were interpreted by one experienced consultant radiologist (EFSUMB Level 3). Results: Upon contrast application, no maternal nor fetal adverse effects were observed. Moreover, no fetal contrast enhancement was observed in any patient. CEUS helped to diagnose renal angiomyolipoma, pyelonephritis, necrotic uterine fibroid, gallbladder polyp, and superior mesenteric vein thrombosis. Conclusions: In our study, off-label use of CEUS showed an excellent safety profile allowing the avoidance of ionizing radiation exposure as well as contrast agents in case of CT or use of gadolinium-based contrast agents in case of MRI. CEUS is a promising diagnostic instrument for facilitating clinical decision-making and improving the management of pregnant women.

2021 ◽  
Vol 22 (4) ◽  
pp. 1983
Author(s):  
Mette L. Johansen ◽  
Reshani Perera ◽  
Eric Abenojar ◽  
Xinning Wang ◽  
Jason Vincent ◽  
...  

Ultrasound imaging is a widely used, readily accessible and safe imaging modality. Molecularly-targeted microbubble- and nanobubble-based contrast agents used in conjunction with ultrasound imaging expand the utility of this modality by specifically targeting and detecting biomarkers associated with different pathologies including cancer. In this study, nanobubbles directed to a cancer biomarker derived from the Receptor Protein Tyrosine Phosphatase mu, PTPmu, were evaluated alongside non-targeted nanobubbles using contrast enhanced ultrasound both in vitro and in vivo in mice. In vitro resonant mass and clinical ultrasound measurements showed gas-core, lipid-shelled nanobubbles conjugated to either a PTPmu-directed peptide or a Scrambled control peptide were equivalent. Mice with heterotopic human tumors expressing the PTPmu-biomarker were injected with PTPmu-targeted or control nanobubbles and dynamic contrast-enhanced ultrasound was performed. Tumor enhancement was more rapid and greater with PTPmu-targeted nanobubbles compared to the non-targeted control nanobubbles. Peak tumor enhancement by the PTPmu-targeted nanobubbles occurred within five minutes of contrast injection and was more than 35% higher than the Scrambled nanobubble signal for the subsequent two minutes. At later time points, the signal in tumors remained higher with PTPmu-targeted nanobubbles demonstrating that PTPmu-targeted nanobubbles recognize tumors using molecular ultrasound imaging and may be useful for diagnostic and therapeutic purposes.


2018 ◽  
Vol 04 (01) ◽  
pp. E2-E15 ◽  
Author(s):  
Christoph Dietrich ◽  
Michalakis Averkiou ◽  
Michael Nielsen ◽  
Richard Barr ◽  
Peter Burns ◽  
...  

Abstract“How to perform contrast-enhanced ultrasound (CEUS)” provides general advice on the use of ultrasound contrast agents (UCAs) for clinical decision-making and reviews technical parameters for optimal CEUS performance. CEUS techniques vary between centers, therefore, experts from EFSUMB, WFUMB and from the CEUS LI-RADS working group created a discussion forum to standardize the CEUS examination technique according to published evidence and best personal experience. The goal is to standardise the use and administration of UCAs to facilitate correct diagnoses and ultimately to improve the management and outcomes of patients.


2021 ◽  
Author(s):  
Dan Zuo ◽  
Ji-Jiang Qian ◽  
Yi Dong ◽  
Wen-Ping Wang ◽  
Xiao-Fan Tian ◽  
...  

Purpose: The purpose of current study was to investigate the value of the late-phase enhancement features of pancreas contrast-enhanced ultrasound (CEUS) in the detection of liver metastases in patients with pancreatic ductal adenocarcinomas (PDAC).Methods: From October 2020 to March 2021, 86 patients were prospectively enrolled. The gold standard of liver metastatic and PDAC lesions were based on histopathologically diagnoses and multiple imaging modalities results. B-mode ultrasound (BMUS) was performed to detect suspected liver metastases before CEUS. During the late phase of pancreas CEUS, the entire liver was scanned again to detect hypoenhanced liver metastases. Liver metastases were confirmed by biopsy and histopathological results. The number and size of liver metastases detected by BMUS and during CEUS late phase were recorded and compared.Results: Suspected liver metastases were detected in 14 patients by BMUS (n = 23). During the late phase of CEUS, hypoenhanced liver metastases were detected in 23 patients (n = 87). When compared with BMUS, whole-liver scan during the late phase of CEUS detected more isoechoic, small, or superficially located lesions. Compared with BMUS, the specificity, sensitivity, positive predictive value, and negative predictive value of CEUS in diagnosing of liver metastases in PDAC patients were significantly improved (96.72% vs. 100%, 48% vs. 92%, 85.71% vs. 100%, and 83.10% vs. 96.83%, respectively) (P < 0.05).Conclusion: The late phase whole liver scan during CEUS of pancreas helps to detect more liver metastases, which is important for further clinical decision-making.


2016 ◽  
Vol 25 (2) ◽  
pp. 205-211 ◽  
Author(s):  
Antonio Giorgio ◽  
Luca Montesarchio ◽  
Piero Gatti ◽  
Ferdinando Amendola ◽  
Paolo Matteucci ◽  
...  

  Background & Aims: Disappearance of portal blood flow and arterial vascularization is the hallmark of hepatocarcinogenesis. The capability of a dynamic imaging modality detecting arterial hypervascularization of small nodules is crucial to promote a rapid diagnostic and therapeutic work-up improving survival. We aimed to evaluate the capability of CEUS to detect arterial vascularization of ≤ 2 cm HCC nodules arising during surveillance so as to shorten the diagnostic and therapeutic work-up. Methods: From October 2009 to September 2014, among 1757 consecutive cirrhotic patients under surveillance with ultrasound (US), 243 patients had new single nodules 7-20 mm; 229/243 had a conclusive histologic diagnosis and comprised the study group. All patients underwent CEUS followed by enhanced MRI and US guided percutaneous 18G needle core biopsy of the nodules. Of the 229 nodules, 27 were hyperechoic, 171 hypoechoic and 31 isoechoic lesions. Results: The histology results revealed that 199/229 nodules were HCC and 30 were benign. Of 199 HCC, CEUS evidenced arterial hypervascularity in 190 nodules (95.5%) (sensitivity 94.48 %, specificity 100%, PPV 100%, NPV 76.92 %). Of the 39 CEUS arterial-unenhanced nodules, 30 were benign and 9 (23%) were well-differentiated HCC. eMRI showed arterial hypervascularity in 199 nodules (86,9%). Of these, only 193 (97%) were histologically HCCs while 6 were benign (sensitivity: 97%, specificity: 80%, PPV: 97%, NPV: 80%). Conclusions: CEUS has a great capability to detect arterial hypervascularity of small HCC. Because only 4.5% of new nodules escape the demonstration of arterial hyervascularity, CEUS must be performed immediately after conventional US to contrast the malignant fate of small lesions arising in a cirrhotic liver.. Abbreviations: CEUS: contrast-enhanced ultrasound; CT: computed tomography; HCC: hepatocellular carcinoma;MRI: magnetic resonance; NPV: negative predictive value; PPV: positive predictive value; US: ultrasonography.


2020 ◽  
Vol 4 ◽  
pp. 8
Author(s):  
Jemianne Bautista Jia ◽  
Eric Mastrolonardo ◽  
Mateen Soleman ◽  
Ilya Lekht

Contrast-enhanced ultrasound (CEUS) is a cost-effective, quick, and non-invasive imaging modality that has yet to be incorporated in uterine artery embolization (UAE). We present two cases that demonstrate the utility of CEUS in UAE for the identification of uterine-ovarian collaterals which otherwise can result in ineffective fibroid treatment and non-target embolization.


2018 ◽  
Vol 84 (2) ◽  
pp. 208-214 ◽  
Author(s):  
R. Viola Mebert ◽  
Beat SchnÜRiger ◽  
Daniel Candinas ◽  
Tobias Haltmeier

Nonoperative management of blunt splenic and hepatic injuries has become the standard of care for hemodynamically stable patients. However, nonoperative management may lead to delayed complications and appropriate follow-up is therefore crucial. The aim of this systematic literature review was to assess the role of different imaging modalities in the follow-up assessment of patients with blunt splenic or hepatic injuries using the PubMed database. Eighteen studies were found to be relevant to the topic. A total of 2725 patients were enrolled in the included studies. Both retrospective and prospective studies, but no randomized controlled trials were found. In these studies, CT, ultrasound, and contrast-enhanced ultrasound were discussed. CT was the most commonly used imaging modality. Taking into account all studies included, only one patient underwent intervention due to a complication diagnosed by follow-up CTscan in the absence of clinical signs and symptoms. This equates to a total of 920 CT scans performed to diagnose one clinically nonevident complication that required intervention. Based on the reviewed literature, routine imaging follow-up CT scans may not be indicated in asymptomatic patients with lower grade blunt splenic or hepatic injuries. Contrast-enhanced ultrasound is a promising alternative imaging modality for the follow-up of these patients.


2015 ◽  
Vol 2015 ◽  
pp. 1-6 ◽  
Author(s):  
John R. Eisenbrey ◽  
Anush Sridharan ◽  
Ji-Bin Liu ◽  
Flemming Forsberg

Nonlinear contrast-enhanced ultrasound imaging schemes strive to suppress tissue signals in order to better visualize nonlinear signals from blood-pooling ultrasound contrast agents. Because tissue does not generate a subharmonic response (i.e., signal at half the transmit frequency), subharmonic imaging has been proposed as a method for isolating ultrasound microbubble signals while suppressing surrounding tissue signals. In this paper, we summarize recent advances in the use of subharmonic imagingin vivo. These advances include the implementation of subharmonic imaging on linear and curvilinear arrays, intravascular probes, and three-dimensional probes for breast, renal, liver, plaque, and tumor imaging.


Author(s):  
Daohui Yang ◽  
Dansong Wang ◽  
Yijie Qiu ◽  
Xiaofan Tian ◽  
Dan Zuo ◽  
...  

AIM: Preoperative suspicion of malignancy in nonfunctioning pancreatic neuroendocrine tumors (pNETs) is mostly based on tumor size. We retrospectively analyzed the contrast enhanced ultrasound (CEUS) features of a series of histopathologically proved nonfunctioning pNETs. METHODS: In this retrospective study, 37 surgery and histologically proved nonfunctioning pNETs were included. All pNETs lesions were incidentally detected by transabdominal ultrasound. B mode ultrasound (BMUS) and CEUS features were reviewed and analyzed. 52 histopathologically proved pancreatic ductal adenocarcinoma (PDACs) lesions were included as a control group. RESULTS: All nonfunctioning pNETs patients showed no typical clinical symptoms. No significant differences were observed in size, echogenicity or internal color flow imaging signal between pNETs and PDAC patients (P >  0.05). Most of nonfunctioning pNETs showed a well-defined tumor margin. The presence of pancreatic duct dilatation was less frequently observed in nonfunctioning pNETs patients (P <  0.05). After injection of ultrasound contrast agents, homogeneous enhancement was more commonly observed in nonfunctioning pNETs group (P <  0.05). During arterial phase of CEUS, most of nonfunctioning pNETs were hyper- or isoenhanced (32/37, 86.5%), whereas most of PDACs were hypoenhanced (34/52, 65.4%) (P <  0.05). Nonenhanced necrosis area was more commonly detected in PDACs (P = 0.012). CONCLUSIONS: CEUS features are helpful for preoperative non-invasive differential diagnosis of nonfunctioning pNETs, assisting further clinical decision-making process.


Sign in / Sign up

Export Citation Format

Share Document