scholarly journals Prophylactic Corneal Cross-Linking in Myopic Femtosecond Laser-Assisted In Situ Keratomileusis: Long-Term Visual and Refractive Outcomes

Optics ◽  
2021 ◽  
Vol 2 (1) ◽  
pp. 55-62
Author(s):  
Federico Alonso-Aliste ◽  
Jonatan Amián-Cordero ◽  
Rahul Rachwani-Anil ◽  
Concepción De-Hita-Cantalejo ◽  
Davide Borroni ◽  
...  

The purpose of our study was to evaluate the safety, effectiveness, predictability, and stability of myopic and astigmatic laser-assisted in situ keratomileusis (LASIK) with simultaneous prophylactic corneal cross-linking (CXL) in thin corneas. In total, 100 eyes from 50 patients who were subjected to myopic and astigmatism femtosecond LASIK with simultaneous prophylactic CXL were included. The design of the study was retrospective, longitudinal, and observational. All patients had a 48-month follow-up. The MEL 80 excimer laser was utilized with the Aberration Smart Ablation platform. CXL treatment was applied when the predicted stromal thickness was less than 330 µm. Patients’ mean age was 30.22 ± 5.97 years. Previous mean spherical equivalent was −5.50 ± 1.65 (−9.50 to −1.13) diopters (D). Postoperative mean spherical equivalent was −0.24 ± 0.29 (−0.85 to +0.50) D. Visual acuity (VA) of 20/20 or better was observed in 87% of the eyes and no eyes experienced VA loss. Spherical equivalent within ±0.50 D was observed in 93% of eyes, and 4% of eyes varied by 0.50 D or more between 3 and 48 months. Prophylactic corneal cross-linking with simultaneous femtosecond laser-assisted in situ keratomileusis in thin corneas proved to be effective, safe, and predictable. The results remained stable after 48 months of follow-up.

2020 ◽  
Author(s):  
Anita Csorba ◽  
Huba Kiss ◽  
Kinga Kránitz ◽  
Zoltán Zsolt Nagy

Abstract Background: Our aim was to evaluate the long-term effects of conventional epithelium-off corneal cross-linking performed on patients with progressive keratoconus. Methods: A retrospective analysis was performed on 34 eyes of 34 patients with progressive keratoconus underwent conventional cross-linking using Pentacam HR Scheimpflug camera. Visual acuity, spherical equivalent, keratometry, pachymetry and corneal topographic indices were analysed preoperatively and at 1, 3, and 6 years after the surgery. Results: Statistically significant decrease was detected at 1 year in spherical equivalent (p = 0.022), with no significant changes afterward (p =0.616). Uncorrected and best corrected distance visual acuity improved significantly in the first postoperative year (p =0.017 and p= 0.003, respectively), and remained stable with no significant changes at further visits (p = 0.203 and p = 0.336, respectively). Significant decrease of central corneal thickness and thinnest corneal thickness was observed at 1 year (both p <0.001), with additional thinning of thinnest corneal pachymetry up to 3 years (p = 0.01). Maximum keratometry and mean keratometry showed significant, continuous improvement between all consecutive visits over the whole follow-up period (all p-values <0.05). Significant improvement was found in the following 5 topographic indices at 1 year: ISV (p = 0.001), IVA (p = 0.028), KI (p = 0.002), CKI (p <0.001 and Rmin (p <0.001), with further improvement up to 3 years in ISV (p = 0.007), in CKI (p = 0.019) and in Rmin (p = 0.015). Rmin showed more improvement up to the end of follow-up (p <0.001).Conclusions: Conventional epithelium-off corneal cross-linking is effective in halting the progression of keratoconus and in regularization of the anterior corneal surface over a long-term follow-up period up to 6 years.


2018 ◽  
Vol 103 (4) ◽  
pp. 565-568 ◽  
Author(s):  
Tian Han ◽  
Ye Xu ◽  
Xiao Han ◽  
Li Zeng ◽  
Jianmin Shang ◽  
...  

AimsTo compare long-term clinical outcomes following small incision lenticule extraction (SMILE) and femtosecond laser-assisted laser in situ keratomileusis (FS-LASIK) for myopia and myopic astigmatism correction.MethodsIn this retrospective study, we enrolled a total of 101 patients (101 eyes) who underwent SMILE or FS-LASIK 3 years prior. Measured parameters included uncorrected distance visual acuity (UDVA), corrected distance visual acuity (CDVA), manifest refraction and corneal wavefront aberrations.ResultsNo significant differences in patient characteristics were found between the two groups. At the 3-year follow-up, UDVA was better than or equal to 20/20 in 90% and 85% (p=0.540) of the eyes; the efficacy indexes were 1.05±0.19 and 1.01±0.21 in the SMILE and FS-LASIK groups, respectively (p=0.352). Safety indexes were 1.19±0.17 and 1.15±0.20 in the SMILE and FS-LASIK groups, respectively (p=0.307). Eighty per cent and 65% of eyes were within ±0.50 D of the attempted spherical equivalent correction after SMILE and FS-LASIK, respectively (p=0.164). Vector analysis revealed no significant differences in astigmatic correction between the two groups (p>0.05). Surgically induced spherical aberration was higher in the FS-LASIK group than in the SMILE group (p<0.001).ConclusionLong-term follow-up analysis suggested that both SMILE and FS-LASIK were safe and equally effective for myopic and astigmatic correction.


2019 ◽  
Vol 2019 ◽  
pp. 1-5 ◽  
Author(s):  
Cristina Nicula ◽  
Radu Pop ◽  
Anca Rednik ◽  
Dorin Nicula

Purpose. The purpose of the current study was to evaluate the long-term functional results based on keratometric measurements, spherical and cylinder equivalent in patients with progressive keratoconus treated with conventional “epi-off” corneal collagen cross-linking (CXL). Methods. We conducted a retrospective study in which 113 eyes from 90 keratoconus-treated patients with CXL between 2006 and 2008 in Oculens Eye Clinic from Cluj-Napoca, Romania, were included. The diagnosis of keratoconus was based on corneal topography and its clinical signs. All patients were evaluated preoperatively, and a follow-up was performed at 1, 3, and 6 months and every year from 1 to 10 years after conventional CXL. Results. All keratometry measurements improved significantly during the follow-up. Compared to preoperative values, the improvement of Kmax become statistically significant at 1 year after CXL (mean change compared to baseline −0.9 D, p<0.001) and remained statistically significant thereafter up to 10 years (mean change compared to baseline −2.3 D, p<0.001). As compared to preoperative values, mean spherical equivalent and mean cylinder improved during the follow-up, from a mean of −6.22 D before CXL to a mean value of −5.0 at 10 years, following CXL for spherical equivalent and from −4.4 D at baseline to −3.4 D at 10 years for cylinder (p<0.05 for both). Uncorrected visual acuity increased, remaining statistically significant, by 0.104 logMAR at 10 years after CXL (p=0.0015), and best-corrected visual acuity increased by 0.135 logMAR at 10 years after CXL (p=0.015). We did not observe any case of severe complication. Conclusion. Our results show that CXL has a favorable effect on the progression of KC. The reduced K values, cylinder and spherical equivalent, and increased visual acuity remained the same 10 years after the procedure.


Author(s):  
David Zadok ◽  
Isaac Avni ◽  
Erez Bakshi ◽  
Irina S Barequet ◽  
Isaac Aizenman ◽  
...  

ABSTRACT Purpose To report refractive, topographic and safety outcomes of corneal cross-linking (CXL) in patients younger than 18 years of age with progressive keratoconus. Materials and methods In this retrospective study, we enrolled 31 eyes of 21 children aged 11 to 17 years that underwent corneal riboflavin-ultraviolet A induced CXL due to progressive keratoconus at three different ophthalmology departments in Israel. They were followed for 3 to 48 months (average 23 ± 13.6 months). Evaluated parameters were uncorrected visual acuity (UCVA), best spectacle corrected visual acuity (BSCVA), manifest refraction, pachymetry, slit- lamp examination and corneal topography at baseline and at 1,3,6,12,24 and 48 months. Results We found a nonsignificant improvement in UCVA and BSCVA with a small reduction of manifest cylinder and no significant change in spherical equivalent or K-values. Following CXL, stability of UCVA and BSCVA at the last follow-up examination was found in 71 and 77% of treated eyes, respectively. No permanent adverse events have been recorded throughout the study period. Conclusion In our series, CXL was a safe procedure in the pediatric population. Stabilization of progressive keratoconus was achieved in visual acuity, refractive and topography parameters with no improvement in corneal indices in contrary to adult CXL treatment. How to cite this article Bakshi E, Barequet IS, Aizenman I, Levinger S, Avni I, Zadok D. Corneal Corss-linking in Patients Younger than 18 Years: Long-term Follow-up in Three Israeli Medical Centers. Int J Kerat Ect Cor Dis 2014;3(2):84-87.


Author(s):  
Ritu Arora ◽  
Sonal Dangda

ABSTRACT Purpose Presenting the course of visually disabling corneal infiltration post uneventful collagen cross-linking (CXL) in a 23 years old male with bilateral keratoconus. Methods A 23 years old male with bilateral keratoconus underwent cross-linking of left eye with indigenous 0.1% riboflavin dye and 370 nm ultraviolet A irradiation. This patient had an uneventful successful cross-linking performed in right eye 6 months prior with good recovery of vision to LogMAR (6/9 Snellen). Results Patient developed diminution of vision, along with redness of eye, photophobia and watering on 3rd day after uneventful cross-linkage. Examination revealed very poor vision; diffuse corneal clouding with multiple superficial stromal infiltrates and incomplete corneal epithelization. A provisional diagnosis of infective keratitis was made, in situ bandage contact lens (BCL) removed and subjected to culture. Intensive fortified topical antibiotics were initiated and steroids withheld. After complete corneal re-epithelization on 6th day, the infiltrations did not decrease in either intensity or number. Response to antibiotics being inadequate, an immune etiology was suspected and full strength topical steroids reinstituted which resulted in slow resolution of infiltration over a 10 weeks period. Last follow-up at 9 months post-CXL, revealed a diffuse stromal haze with unaided visual acuity of LogMAR 0.8 6/36 and best-corrected visual acuity (BCVA) of 0.3 (6/12) with use of a rigid gas permeable lens. Conclusion Sterile infiltration post-CXL requiring intense topical steroids is a rare complication of CXL and needs to be differentiated from infective keratitis. How to cite this article Bhattacharyya M, Singh K, Mutreja A, Dangda S, Arora R. Diffuse Sterile Corneal Infiltration: An Unusual Complication Post Collagen Cross-linkage. Int J Kerat Ect Cor Dis 2015;4(3):115-119.


2017 ◽  
Vol 102 (1) ◽  
pp. 31-36 ◽  
Author(s):  
Jonghyun Lee ◽  
Jin Hyoung Kim ◽  
Doh Lee ◽  
Ji Woong Chang ◽  
Joo Youn Shin ◽  
...  

PurposeTo evaluate long-term outcome of femtosecond laser-assisted lamellar keratectomy (FLK) with phototherapeutic keratectomy (PTK) in patients with anterior corneal stromal dystrophies.MethodsA total of 10 eyes from seven patients who underwent FLK were included. The patients had suffered from recurrent corneal erosion or visual disturbance in anterior corneal dystrophies (five Avellino dystrophies and two lattice dystrophies). Planar-shaped lamellar keratectomy was performed using femtosecond laser. The amount of corneal excision was determined by the depth of corneal opacity. Additional PTK with mitomycin C application was performed for smoothening of corneal cut surface. The patients were evaluated with following parameters: uncorrected visual acuity, best-corrected visual acuity (BCVA), mean anterior keratometric value, corneal irregularity, corneal high-order aberrations (HOA) and the recurrence of corneal erosion.ResultsMean duration of follow-up was 64 months (2.5–9.5 years). The BCVA improved more than two lines of Snellen chart at last visit. The changes of keratometric values were within ±1 D in eight out of 10 eyes. Corneal irregularities in central 5 mm cornea and the values of total corneal HOA in central 6 mm cornea decreased by 0.3–3.1 D and 0.01–2.2 µm, respectively. Corneal erosion did not recur in any of those patients during follow-up and corneal dystrophy did not recur in eight out of 10 eyes.ConclusionIn anterior corneal stromal dystrophies, FLK with PTK can be an effective surgical option to improve VA through decreasing corneal irregularities and HOA, while minimising corneal curvature changes.


2021 ◽  
pp. 112067212110528
Author(s):  
Abdelrahman Salman ◽  
Ali Ali ◽  
Shaaban Rafea ◽  
Rana Omran ◽  
Buraa Kubaisi ◽  
...  

Aim To evaluate the long-term outcomes of corneal cross-linking (CXL) in patients with progressive keratoconus. Method In this retrospective non-comparative study, forty-five eyes of 31 patients with progressive keratoconus were treated with 30 min “epi-off” corneal cross-linking. The visual, refractive, topographic and tomographic outcomes were evaluated preoperatively and at least 10 years after cross-linking. Results Ten years post-corneal cross-linking, the mean anterior maximum keratometry decreased (−2.10 ± 3.25 D, P = 0.0001). Conversely, the posterior maximum keratometry increased (6.38 ± 9.79 D, P = 0.065). Both uncorrected and corrected distance visual acuity improved (LogMAR −0.08 ± 0.30) and (LogMAR −0.05 ± 0.21), respectively (P > 0.05, both). A statistically significant hyperopic shift was observed postoperatively (0.70 ± 1.31 D, P = 0.0009). The anterior topographic cylinder values revealed no change (−0.17 ± 1.31 D, P = 0.3), whereas the mean posterior cylinder values decreased (absolute value increased) significantly compared to baseline from −1.31 ± 0.97 D to −1.82 ± 1.78 D, (P < 0.05). The minimum corneal thickness values decreased significantly (−35.11 ± 48.63 µm, P = 0.0001). Four eyes (8.8%) showed more than 1 D increase in the anterior maximum keratometry. Conclusion This protocol and duration of Epi-off corneal cross-linking was found to be effective in halting keratoconus progression over the follow up period (10 years). Anterior corneal flattening and a hyperopic shift were observed. A statistically significant increase in the posterior corneal cylinder was observed. Although, not reaching statistical significance, the logMAR uncorrected and corrected visual acuity were improved.


2018 ◽  
Vol 12 (1) ◽  
pp. 256-263 ◽  
Author(s):  
Mohammad M. Shehadeh ◽  
Mohammad T. Akkawi ◽  
Ammar A. Aghbar ◽  
Muna T. Musmar ◽  
Malak N Khabbas ◽  
...  

Background: Laser corneal refractive surgery suits, technology and nomograms are improving with time. This may improve the refractive and visual outcomes of the patients. Objectives: To evaluate the safety, efficacy, stability, and predictability of wavefront-optimized photorefractive keratectomy and Laser-assisted in-situ keratomileusis in patients with myopia and myopic astigmatism over 1-year using WaveLight® EX500 Excimer Laser machine. Methods: In this prospective cohort study, refractive and visual outcomes in 596 eyes (365 patients), either having myopia or myopic astigmatism were assessed. Patients were divided into Two groups: 1) Patients who underwent PRK (53 eyes have myopia and 217 eyes have myopic astigmatism), 2) Patients who underwent LASIK (53 eyes have myopia and 273 eyes have myopic astigmatism). Results: At 12 months postoperatively 94.3% of the myopic patients reached their preoperative best corrected distance visual acuity at the final one year follow up visit post PRK and LASIK. In patients with myopic astigmatism who underwent LASIK and PRK, 95.2%, and 96.3% of the patients reached their preoperative best corrected distance visual acuity at the final one year follow up visit post LASIK and PRK, respectively. The efficacy and safety indices were 1.00 or more for all groups with no eye lost any line of best corrected distance visual acuity. Conclusion: Our study results confirm the excellent efficacy, safety, good predictability and stability of myopia / myopic astigmatism correction by either wavefront- optimized LASIK or PRK over 1-year follow-up without significant differences between them using the WaveLight® EX500 excimer laser system.


2018 ◽  
Vol 2018 ◽  
pp. 1-6 ◽  
Author(s):  
Alper Ağca ◽  
İhsan Çakır ◽  
Beril Tülü Aygün ◽  
Dilek Yaşa ◽  
Yusuf Yıldırım ◽  
...  

Purpose. To report long-term visual and refractive results of small-incision lenticule extraction (SMILE) in treatment of high myopia. Materials and Methods. Medical records of patients who underwent SMILE for surgical correction of myopia or myopic astigmatism were retrospectively reviewed. Only patients with a preoperative spherical equivalent of subjective manifest refraction (SE) ≥ 6 D and a postoperative follow-up of 5 years were included in the study. Uncorrected distance visual acuity (UDVA), corrected distance visual acuity (CDVA), and SE were analyzed preoperatively and at 1-, 3-, and 5-year postoperative periods. Results. Thirty-seven eyes of 37 patients were included in the study. The mean attempted SE was −7.47 ± 1.10 D (range −6.00 to −10.00 D). At the 5-year visit, the mean difference between achieved and attempted SE was −0.43 ± 0.47 (0.50 to −1.25 D). Mean postoperative UDVA and CDVA were 0.20 ± 0.18 and 0.06 ± 0.08 logMAR, respectively. At the 1-year visit, 70% and 97% of the eyes were within ±0.50 D and ±1.00 D of the intended correction. At the 5-year follow-up, 59% and 92% percent of the eyes were within ±0.50 D and ±1.00 D of the intended SE, respectively. At the 5-year visit, the efficacy index was 0.89 ± 0.26 and the safety index was 1.16 ± 0.20. Fifty-four percent of the eyes gained one or more lines of CDVA. Conclusion. SMILE with an intended correction of up to a spherical equivalent of 10 D is safe and effective. However, there is regression of the refractive effect over extended follow-up.


Sign in / Sign up

Export Citation Format

Share Document