Optics
Latest Publications


TOTAL DOCUMENTS

51
(FIVE YEARS 51)

H-INDEX

2
(FIVE YEARS 2)

Published By MDPI AG

2673-3269

Optics ◽  
2022 ◽  
Vol 3 (1) ◽  
pp. 19-34
Author(s):  
Milo W. Hyde ◽  
Olga Korotkova

Generalizing our prior work on scalar multi-Gaussian (MG) distributed optical fields, we introduce the two-dimensional instantaneous electric-field vector whose components are jointly MG distributed. We then derive the single-point Stokes parameter probability density functions (PDFs) of MG-distributed light having an arbitrary degree and state of polarization. We show, in particular, that the intensity contrast of such a field can be tuned to values smaller or larger than unity. We validate our analysis by generating an example partially polarized MG field with a specified single-point polarization matrix using two different Monte Carlo simulation methods. We then compute the joint PDFs of the instantaneous field components and the Stokes parameter PDFs from the simulated MG fields, while comparing the results of both Monte Carlo methods to the corresponding theory. Lastly, we discuss the strengths, weaknesses, and applicability of both simulation methods in generating MG fields.


Optics ◽  
2022 ◽  
Vol 3 (1) ◽  
pp. 8-18
Author(s):  
Haroon Zafar ◽  
Junaid Zafar ◽  
Faisal Sharif

Deep Neural Networks (DNNs) are nurturing clinical decision support systems for the detection and accurate modeling of coronary arterial plaques. However, efficient plaque characterization in time-constrained settings is still an open problem. The purpose of this study is to develop a novel automated classification architecture viable for the real-time clinical detection and classification of coronary artery plaques, and secondly, to use the novel dataset of OCT images for data augmentation. Further, the purpose is to validate the efficacy of transfer learning for arterial plaques classification. In this perspective, a novel time-efficient classification architecture based on DNNs is proposed. A new data set consisting of in-vivo patient Optical Coherence Tomography (OCT) images labeled by three trained experts was created and dynamically programmed. Generative Adversarial Networks (GANs) were used for populating the coronary aerial plaques dataset. We removed the fully connected layers, including softmax and the cross-entropy in the GoogleNet framework, and replaced them with the Support Vector Machines (SVMs). Our proposed architecture limits weight up-gradation cycles to only modified layers and computes the global hyper-plane in a timely, competitive fashion. Transfer learning was used for high-level discriminative feature learning. Cross-entropy loss was minimized by using the Adam optimizer for model training. A train validation scheme was used to determine the classification accuracy. Automated plaques differentiation in addition to their detection was found to agree with the clinical findings. Our customized fused classification scheme outperforms the other leading reported works with an overall accuracy of 96.84%, and multiple folds reduced elapsed time demonstrating it as a viable choice for real-time clinical settings.


Optics ◽  
2022 ◽  
Vol 3 (1) ◽  
pp. 1-7
Author(s):  
Muddasir Naeem ◽  
Noor-ul-ain Fatima ◽  
Mukhtar Hussain ◽  
Tayyab Imran ◽  
Arshad Saleem Bhatti

We report the design simulation of the Raman spectrometer using Zemax optical system design software. The design is based on the Czerny–Turner configuration, which includes an optical system consisting of an entrance slit, two concave mirrors, reflecting type diffraction grating and an image detector. The system’s modeling approach is suggested by introducing the corresponding relationship between detector pixels and wavelength, linear CCD receiving surface length and image surface dimension. The simulations were carried out using the POP (physical optics propagation) algorithm. Spot diagram, relative illumination, irradiance plot, modulation transfer function (MTF), geometric and encircled energy were simulated for designing the Raman spectrometer. The simulation results of the Raman spectrometer using a 527 nm wavelength laser as an excitation light source are presented. The present optical system was designed in sequential mode and a Raman spectrum was observed from 530 nm to 630 nm. The analysis shows that the system’s image efficiency was quite good, predicting that it could build an efficient and cost-effective Raman spectrometer for optical diagnostics.


Optics ◽  
2021 ◽  
Vol 2 (4) ◽  
pp. 292-305
Author(s):  
Pedro Serra ◽  
Ángel Sánchez Trancón ◽  
Oscar Torrado Sierra ◽  
António Baptista ◽  
Santiago Cerpa Manito

Posterior chamber phakic intraocular lens implantation is a refractive technique for the correction of myopia. This study aimed to identify those factors contributing to variability in postoperative refraction. Methods: This retrospective study evaluated 73 eyes (one eye per patient) implanted with myopic implantable collamer lenses (ICL). Eyes were divided into two groups, the low myopic group (LMG) (ICL > −9.5 DS) and the high myopic group (HMG) (ICL ≤ −9.5 DS), to compare the predictability, efficacy index, and postoperative refraction between groups. The association of postoperative refraction with anatomical, demographic, and optical features was assessed through correlation analysis and investigated using ray-tracing. Results: Postoperative refraction at 3 months for the whole group was close to emmetropia at −0.02 ± 0.37 DS, the LMG tended toward myopia and the HMG, toward hyperopia. The results showed that 65% and 54% of the eyes had postoperative refraction of within ±0.25 DS, respectively, in the LMG and HMG, and in both groups, 100% were within ±1.00 DS. ICL implantation had a higher efficacy index in the HMG (1.13 ± 0.15) than in the LMG (1.04 ± 0.15). Postoperative refraction was positively associated with the vault (R = 0.408) and negatively correlated with ICL power (R = −0.382). Conclusion: The predictability and effectiveness of ICL implantation is high in a wide range of myopias. Considering the expected vault and including accurate vertex measurements would contribute to improving the predictability of the results.


Optics ◽  
2021 ◽  
Vol 2 (4) ◽  
pp. 284-291
Author(s):  
Victoria Paige Stinson ◽  
Serang Park ◽  
Micheal McLamb ◽  
Glenn Boreman ◽  
Tino Hofmann

One-dimensional photonic crystals composed of alternating layers with high- and low-density were fabricated using two-photon polymerization from a single photosensitive polymer for the infrared spectral range. By introducing single high-density layers to break the periodicity of the photonic crystals, a narrow-band defect mode is induced. The defect mode is located in the center of the photonic bandgap of the one-dimensional photonic crystal. The fabricated photonic crystals were investigated using infrared reflection measurements. Stratified-layer optical models were employed in the design and characterization of the spectral response of the photonic crystals. A very good agreement was found between the model-calculated and measured reflection spectra. The geometric parameters of the photonic crystals obtained as a result of the optical model analysis were found to be in good agreement with the nominal dimensions of the photonic crystal constituents. This is supported by complimentary scanning electron microscope imaging, which verified the model-calculated, nominal layer thicknesses. Conventionally, the accurate fabrication of such structures would require layer-independent print parameters, which are difficult to obtain with high precision. In this study an alternative approach is employed, using density-dependent scaling factors, introduced here for the first time. Using these scaling factors a fast and true-to-design method for the fabrication of layers with significantly different surface-to-volume ratios. The reported observations furthermore demonstrate that the location and amplitude of defect modes is extremely sensitive to any layer thickness non-uniformities in the photonic crystal structure. Considering these capabilities, one-dimensional photonic crystals engineered with defect modes can be employed as narrow band filters, for instance, while also providing a method to quantify important fabrication parameters.


Optics ◽  
2021 ◽  
Vol 2 (4) ◽  
pp. 276-283
Author(s):  
Wei Xiong ◽  
Liyang Ou ◽  
Xuezhou Chen ◽  
Chaobo Li

As a kind of resonant device, the modulation efficiency of the photo-elastic modulator (PEM) is determined by its inherent resonance characteristics, including the resonance frequency and quality factor (Q-factor). The existing methods used to characterize the resonance performance of the PEM are mainly based on the optical method to measure the vibration parameters, but these methods are more complex, have a high cost, and are not able to accurately measure the quality factor. Therefore, this paper proposes an electrical characterization method based on impedance measurement. In this method, an equivalent circuit model for the PEM is established. By measuring the impedance vs. frequency curve of the PEM and using the equivalent circuit model for fitting analysis, we can obtain the parameters of the equivalent circuit model. With these parameters, we can eventually calculate the natural resonance frequency and quality factor. The above method was applied to some commercial PEM products for experimental verification. The experimental results show that this method can accurately measure the natural resonance frequency and quality factor of the PEM, and the error is less than 0.03%.


Optics ◽  
2021 ◽  
Vol 2 (4) ◽  
pp. 266-275
Author(s):  
Diego de Ortueta ◽  
Dennis von Rüden ◽  
Samuel Arba-Mosquera

Transepithelial photorefractive keratectomy (TransPRK) is an established surface ablation technique used to correct refractive errors. Using anterior segment optical coherence (AS-OCT), it is now possible to measure the epithelium thickness and input these data into the laser platform. In this study, we explore whether better results were obtained in this way. To this end, we retrospectively analyze the results from a low-myopia group treated with a customized epithelium thickness, as measured using AS-OCT, and compare them with the results from a group treated with an optimized standard epithelium thickness. The customized epithelium profile group contains more eyes with vision better than 20/20, and more eyes in this group gain one line of corrected distance visual acuity (CDVA). In conclusion, with the customized epithelium thickness, we obtain superior results using TransPRK in low-myopia corrections.


Optics ◽  
2021 ◽  
Vol 2 (4) ◽  
pp. 259-265
Author(s):  
Yujian Sun ◽  
Yongcao Zhang ◽  
Yilin Li

Luminescent solar concentrators (LSCs) have been widely studied for their potential application as building-integrated photovoltaics (BIPV). While numerous efforts have been made to improve the performance, the photothermal (PT) properties of LSCs are rarely investigated. In this report, we studied the PT properties of an LSC with a power conversion efficiency (PCE) of 3.27% and a concentration ratio of 1.42. The results showed that the total PT power of the LSC was 13.2 W, and the heat was concentrated on the edge of the luminescent waveguide with a high heat power density of over 200 W m−2.


Optics ◽  
2021 ◽  
Vol 2 (4) ◽  
pp. 251-258
Author(s):  
Javier Gamo

The need for remote teaching tools in all education levels has experienced a big increase due to COVID-19 pandemic. Laboratory practical sessions have not been an exception, and many online and offline tools have been made available to respond to the lockdown of teaching facilities. This paper presents a software testbed named OPTILAB for teaching diffraction experiments to engineering students. The software simulates classical diffraction apertures (single slit, double slit, circular slit) under a wide variety of conditions. Explanation about the Physics behind the diffraction phenomenon is also included in OPTILAB to increase the students’ self-learning experience. Originally conceived as a complement to on-site teaching, due to COVID-19 pandemic OPTILAB has been adopted as the basic tool to build a brand-new, virtual laboratory session about diffraction in Physics III course (biomedical engineering) at Carlos III University of Madrid. Results obtained by the students taking this virtual lab during Fall 2020 are presented and discussed.


Optics ◽  
2021 ◽  
Vol 2 (4) ◽  
pp. 236-250
Author(s):  
Mahesh N. Jayakody ◽  
Asiri Nanayakkara ◽  
Eliahu Cohen

We theoretically analyze the case of noisy Quantum walks (QWs) by introducing four qubit decoherence models into the coin degree of freedom of linear and cyclic QWs. These models include flipping channels (bit flip, phase flip and bit-phase flip), depolarizing channel, phase damping channel and generalized amplitude damping channel. Explicit expressions for the probability distribution of QWs on a line and on a cyclic path are derived under localized and delocalized initial states. We show that QWs which begin from a delocalized state generate mixture probability distributions, which could give rise to useful algorithmic applications related to data encoding schemes. Specifically, we show how the combination of delocalzed initial states and decoherence can be used for computing the binomial transform of a given set of numbers. However, the sensitivity of QWs to noisy environments may negatively affect various other applications based on QWs.


Sign in / Sign up

Export Citation Format

Share Document