scholarly journals On the Role of Polymer Viscoelasticity in Enhanced Oil Recovery: Extensive Laboratory Data and Review

Polymers ◽  
2020 ◽  
Vol 12 (10) ◽  
pp. 2276
Author(s):  
Alexander Rock ◽  
Rafael E. Hincapie ◽  
Muhammad Tahir ◽  
Nils Langanke ◽  
Leonhard Ganzer

Polymer flooding most commonly uses partially hydrolyzed polyacrylamides (HPAM) injected to increase the declining oil production from mature fields. Apart from the improved mobility ratio, also the viscoelasticity-associated flow effects yield additional oil recovery. Viscoelasticity is defined as the ability of particular polymer solutions to behave as a solid and liquid simultaneously if certain flow conditions, e.g., shear rates, are present. The viscoelasticity related flow phenomena as well as their recovery mechanisms are not fully understood and, hence, require additional and more advanced research. Whereas literature reasonably agreed on the presence of these viscoelastic flow effects in porous media, there is a significant lack and discord regarding the viscoelasticity effects in oil recovery. This work combines the information encountered in the literature, private reports and field applications. Self-gathered laboratory data is used in this work to support or refuse observations. An extensive review is generated by combining experimental observations and field applications with critical insights of the authors. The focus of the work is to understand and clarify the claims associated with polymer viscoelasticity in oil recovery by improvement of sweep efficiency, oil ganglia mobilization by flow instabilities, among others.

Author(s):  
John M. Pietralik ◽  
Chris S. Schefski

The three groups of parameters that affect flow-accelerated corrosion (FAC) are flow conditions, water chemistry, and materials. Nuclear power plant (NPP) data and laboratory tests confirm that under alkaline water chemistry there is a close relationship between local flow conditions and FAC rates in piping components. The knowledge of local flow effects can be useful for developing targeted inspection plans for piping components, predicting the location of the highest FAC rate for a given piping component, and determining what piping components should be replaced. A similar evaluation applies also to FAC in heat transfer equipment such as heat exchangers and steam generators. The objective of this paper is to examine the role of flow and mass transfer in bends under FAC conditions. Bends experience increased FAC rates compared to straight pipes, and are the most common components in piping systems. When the flow effects are dominant, the FAC rate is proportional to the mass flux of ferrous ions, which, in turn, is proportional to the mass transfer coefficient in the flowing water. The mass transfer coefficient describes the intensity of the transport of corrosion products (ferrous ions) from the oxide-water interface into the bulk water. Therefore, this parameter can be used for predicting the local distribution of the FAC rate. The current paper presents plant and laboratory evidence of the relationship between local mass transfer conditions and the FAC rate in bends. It shows correlations for mass transfer coefficients in bends and reviews the most important flow parameters affecting the mass transfer coefficient. The role of bend geometry and, in particular, the short and long radii, surface roughness, wall shear stress, and local turbulence is discussed. Computational fluid dynamics calculations and plant artefact measurements for short-radius and long radius bends are presented. The effect of the close proximity of two bends on FAC rate is also examined based on CANDU™ NPP inspection data and compared with literature data.


Blood ◽  
2012 ◽  
Vol 120 (21) ◽  
pp. 5191-5191
Author(s):  
Khon C. Huynh ◽  
Volker R. Stoldt ◽  
Marianna Gyenes ◽  
Rüdiger E. Scharf

Abstract Abstract 5191 Introduction: To fulfill their role in hemostasis, circulating platelets need to irreversibly adhere to the site of vascular injury and to resist to shear stress generated by the flowing blood. We previously reported that there is a relationship between the conformation of fibronectin (Fn) and its role in platelet adhesion and aggregation (Huynh, K. C. et al., ASH Annual Meeting Abstract, 2011. 118(21): p. 2209). In the present study, we examined the effect of shear stress on the assembly of Fn by adherent platelets. Moreover, we studied the role of β3 integrins (αIIbβ3 and αvβ3) in Fn assembly under flow conditions. Methods: Alexa fluor 488-conjugated fibronetin (Fn488) was added to suspensions of washed platelets (108/ml) in HEPES Tyrode buffer. CaCl2 (2 mM) and ADP (10 μM) were added immediately prior to the experiments. The samples (150 μl) were subsequently applied onto plates precoated with 50 μg/ml Fn. A DiaMed Impact-R device was used to generate shear rates of 500 s−1 or 5000 s−1 for 2 min or 10 min. Nonadherent platelets were removed by washing with PBS buffer followed by addition of 150 μl of 2 % DOC lysis buffer. Lysates were collected and total protein concentrations were determined by Bradford assay. The DOC-insoluble pellets containing Fn fibrils were isolated by centrifugation at 13, 500 rpm for 20 min. Pellets were then solubilized with 100 μl of 1 % SDS buffer. Equal amounts of samples based on total protein concentrations were loaded onto wells of 96-well microplates. Fluorescence signals from Fn488 of samples were recorded by a Fluoroskan microplate reader. In some experiments, abciximab (anti-β3, 10 μg/ml) or LM609 (anti-αvβ3, 5 μg/ml) antibody, were added to platelet mixtures before loading onto Fn precoated plates. All data were collected from at least three different experiments and analyzed using GraphPad Quickcals. To test for statistical differences, student's t-test was used. Results: Fn assembly by adherent platelets was strongly affected by the applied shear rate but not by the exposure time to shear. At a shear rate of 500 s−1, there were no insoluble Fn fibrils detectable in samples with adherent platelets after 2 or 10 min. When shear rates increased from 500 s−1 to 5000 s−1, the amount of insoluble Fn detectable on platelets after 2 and 10 min increased significantly (p < 0. 05) suggesting that adherent platelets exposed to high shear rates assemble more Fn fibrils on their surface. However, prolongation of exposure time to shear from 2 to 10 min did not result in significantly more Fn assembled by adherent platelets. By contrast, there were no insoluble fibrils that could be detected with adherent platelets under static conditions for 2 and 10 min. After 2 min at a shear rate of 5000 s−1, platelets blocked with abciximab showed a significant decrease in the amounts of insoluble Fn fibrils in comparison with control experiments (no antibody) (p = 0. 02). Similar inhibitory effects could be seen with platelets treated with LM609. In parallel experiments in which 10 min at 5000 s−1 were applied, both abciximab and LM609 had an inhibitory effect on Fn fibrillogenesis with a stronger effect by abciximab. Taken together, these data show that αvβ3 even at the low expression on platelets plays a major role in initiating the fibrillogenesis of Fn under high shear rate conditions, whereas αIIbβ3 contributes to the progression of Fn fibrils formation subsequently. Conclusion: Our observations document that the assembly of Fn on the surface of adherent platelets is strongly affected by shear rate conditions. In addition, our data imply that, despite its lower expression on platelet surface, αvβ3 provides a significant contribution in initiating the Fn assembly under high flow conditions, as compared with αIIbβ3. By contrast, αIIbβ3 with its abundant amount on the platelet surface probably exerts its effect in the later phase of Fn fibrillogenesis. The present findings support the contention that not a single integrin or Fn binding domain, but multiple interaction steps including different molecules and Fn domains may be involved in assembling Fn. Disclosures: No relevant conflicts of interest to declare.


1987 ◽  
Author(s):  
E Bastida ◽  
G Escolar ◽  
R Castillo ◽  
A Ordinas ◽  
J J Sixma

Fibronectin (FN) plays a role in several adhesion mediated functions including the interaction of platelets with subendothelium.We investigated the role of plasma FN in platelet adhesion and platelet thrombus formation under flow conditions.To do this we used two different perfusion models:1)the annular chamber with α -chymotrypsin-treated rabbit vessel segments and 2)the flat chamber with coverslips coated with fibrillar purified human collagen type III.Perfusates consisted of washed platelets, and washed red blood celIs,suspended in normal or FN-depleted plasma.Perfusions were carried out for 10 min at shear rates of 300 or 1300 sec™1 Platelet deposition and thrombus dimensions were morphometrically evaluated by a computerized system. We found that depletion of plasma FN significantly reduced the percentage of total coverage surface and percentage of platelet thrombus, at both shear rates studied, and in both perfusion systems (p < 0.01)(p < 0.01).The dimensions of the platelet thrombi formed in perfusions at high shear rate were also significantly reduced in perfusions carried out with FN-depleted plasma.(p < 0.01). Addition of purified FN to FN-depleted perfusates restored all the values to those measured in the control perfusions.These results indicate that, in addition to supporting platelet adhesion to the subendothelium and to fibrillar collagen, FN contributes to platelet thrombus formation under flow conditions.


1975 ◽  
Vol 15 (04) ◽  
pp. 338-346 ◽  
Author(s):  
M.T. Szabo

Abstract Numerous polymer floods were performed in unconsolidated sand packs using a C14-tagged, cross-linked, partially hydrolyzed ployacrylamide, and the data are compared with brine-flood performance in the same sands. performance in the same sands. The amount of "polymer oil" was linearly proportional to polymer concentration up to a proportional to polymer concentration up to a limiting value. The upper limit of polymer concentration yielding additional polymer oil was considerably higher for a high-permeability sand than for a low-permeability sand. It is shown that a minimum polymer concentration exists, below which no appreciable polymer oil can be produced in high-permeability sands. The effect of polymer slug size on oil recovery is shown for various polymer concentrations, and the results from these tests are used to determine the optimum slug size and polymer concentration for different sands. The effect of salinity was studied by using brine and tap water during polymer floods under similar conditions. Decreased salinity resulted in improved oil recovery at low, polymer concentrations, but it had little effect at higher polymer concentrations. Polymer injection that was started at an advanced stage of brine flood also improved the oil recovery in single-layered sand packs. Experimental data are presented showing the effect of polymer concentration and salinity on polymer-flood performance in stratified reservoir polymer-flood performance in stratified reservoir models. Polymer concentrations in the produced water were measured by analyzing the radioactivity of effluent samples, and the amounts of retained polymer in the stratified models are given for each polymer in the stratified models are given for each experiment. Introduction In the early 1960's, a new technique using dilute polymer solutions to increase oil recovery was polymer solutions to increase oil recovery was introduced in secondary oil-recovery operations. Since then, this new technique has attained wide-spread commercial application. The success and the complexity of this new technology has induced many authors to investigate many aspects of this flooding technique. Laboratory and field studies, along with numerical simulation of polymer flooding, clearly demonstrated that polymer additives increase oil recovery. polymer additives increase oil recovery. Some of the laboratory results have shown that applying polymers in waterflooding reduces the residual oil saturation through an improvement in microscopic sweep efficiency. Other laboratory studies have shown that applying polymer solutions improves the sweep efficiency in polymer solutions improves the sweep efficiency in heterogeneous systems. Numerical simulation of polymer flooding, and a summary of 56 field applications, clearly showed that polymer injection initiated at an early stage of waterflooding is more efficient than when initiated at an advanced stage. Although much useful information has been presented, the experimental conditions were so presented, the experimental conditions were so variable that difficulties arose in correlating the numerical data. So, despite this good data, a systematic laboratory study of the factors influencing the performance of polymer flooding was still lacking in the literature. The purpose of this study was to investigate the effect of polymer concentration, polymer slug size, salinity in the polymer bank, initial water saturation, and permeability on the performance of polymer floods. The role of oil viscosity did not constitute a subject of this investigation. However, some of the data indicated that the applied polymer resulted in added recovery when displacing more viscous oil. The linear polymer-flood tests were coupled with tests in stratified systems, consisting of the same sand materials used in linear flood tests. Thus, it was possible to differentiate between the role of polymer in mobility control behind the flood front in each layer and its role in mobility control in the entire stratified system through improvement in vertical sweep efficiency. A radioactive, C14-tagged hydrolyzed polyacrylamide was used in all oil-recovery tests. polyacrylamide was used in all oil-recovery tests. SPEJ P. 338


1987 ◽  
Author(s):  
A Ordinas ◽  
E Bastida ◽  
M Garrido ◽  
J Monteagudo ◽  
L de Marco ◽  
...  

Native Von Willebrand factor (NvWF) binds to platelets activated by thrombin, ADP or ristocetin, and also supports the adhesion of platelets to subendothelium at high shear rates. In contrast, asialo von Willebrand factor (AvWF) induces platelet aggregation in absence of platelet activators. We investigated the role of AvWF in supporting the adhesion of platelets to rabbit vessel subendothelium under flow conditions at a shear rate of 2000 sec-1 for 5 min using the Baumgartner perfusion system. We also studied the effects of blockage of platelet GPIb or GPIIb/IIIa on platelet adhesion using monoclonal antibodies (Mabs),and we measured the rate of binding of 111I-labeled NvWF and AvWF to subendothelium. Perfusates consisted of washed platelts and red cells resuspended in a 4% human albumin solution to which increasing concentrations of NvWF or AvWF had been added. Platelets interacting with the perfused vessels were evaluated morphometrically using a computerized system. At a concentration of 1.2 /ig/ml the percentage of total coverage surface was 21.3 ± 4.8% and 40.0±14.6%, for NvWF and AvWF, respectively (p<0.01). Addition of either Mab against GPIb (LJlbl) or against GPIIb/IIIa (CP8) to the perfusates, reduced platelet deposition (p <0.01). The rates of binding of 111I-labeled NvWF and AvWF to perfused vessel subendothelium were similar (0.83±0.1μg and 0.95±0.1 μg ,respectively).Our results indicate that AvWF enhances the interaction of washed platelets with the vessel subendothelium under flow conditions. Furthermore, they suggest that this effect is related to the interaction of AvWF with platelets and not to an increased affinity of AvWF for subendothelium.


Blood ◽  
1987 ◽  
Vol 70 (5) ◽  
pp. 1437-1442 ◽  
Author(s):  
E Bastida ◽  
G Escolar ◽  
A Ordinas ◽  
JJ Sixma

Abstract Fibronectin (FN) plays a role in several adhesion mediated functions including the interaction of platelets with subendothelium. We investigated the role of plasma FN in platelet adhesion and platelet thrombus formation under flow conditions. We used two different perfusion models: the annular chamber with alpha-chymotrypsin-treated rabbit vessel segments, and the flat chamber with coverslips coated with fibrillar purified human collagen type III. Perfusates consisted of washed platelets and washed RBCs, suspended in normal or FN-depleted plasma. Perfusions were carried out for ten minutes at shear rates of 300 or 1,300 s-1. Platelet deposition and thrombus dimensions were evaluated morphometrically by a computerized system. We found that depletion of plasma fibronectin significantly reduced the percentage of total coverage surface and percentage of platelet thrombus, at both shear rates studied, and in both perfusion systems (P less than .01) (P less than .01). The dimensions of the platelet thrombi formed in perfusions at high shear rate were also significantly reduced in perfusions carried out with FN depleted plasma (P less than .01). Addition of purified FN to FN-depleted perfusates restored all values to those measured in the control perfusions. These results indicate that plasma FN is required for platelet aggregate and thrombus formation following adhesion under flow conditions.


2021 ◽  
Vol 5 (17) ◽  
pp. 3468-3477
Author(s):  
Fraser L. Macrae ◽  
Frauke Swieringa ◽  
Johan W. M. Heemskerk ◽  
Robert A. S. Ariëns

Abstract Fibrinogen γ' accounts for 3% to 40% of plasma fibrinogen. Earlier studies indicated that fibrinogen γ' forms altered fibrin clots under static conditions, whereas clinically, altered plasma γ' levels are associated with arterial and venous thrombosis. However, the effects of static vs flow conditions on the role of γ′ throughout the pathophysiological range is unknown. This study explores the effects of γ' levels on clot formation and structure in static and flow conditions. Coagulation of plasma samples with low (n = 41; 3%), normal (n = 45; 10%), or high (n = 33; 30%) γ′ levels were compared with that of purified fibrinogen mixtures with increasing ratios of γ′ (3%, 10%, 30%). Clots were analyzed by confocal microscopy, permeation, turbidity, and lysis techniques. In a novel 2-step flow-perfusion model, fibrinogen-deficient plasma repleted with increasing ratios of γ′ (3%, 10%, 30%) or plasmas with low (n = 5, 3%) or high (n = 5, 30%) γ′ were flowed over preformed platelet aggregates at arterial (500 s−1) and venous (150 s−1) shear rates. Increasing γ′ percentages within the pathophysiological range (3%-30%) did not result in any change in clot-formation rates; however, it led to significantly higher clot density, thinner fibers, and slower lysis in static conditions. Under flow at arterial shear, high γ′ (30%) led to faster (+44.1%-75.3%) and increased (+104%-123%) fibrin deposition, with clots exhibiting a larger volume (+253%-655%) and height (+130%-146%). These trends were magnified at venous shear. Overall, our findings demonstrate the significant impact of pathophysiological fibrinogen γ′ levels on clot structure and provide new flow-dependent mechanisms to explain how γ′ increases thrombosis risk.


2021 ◽  
Author(s):  
Mursal Zeynalli ◽  
Emad W. Al-Shalabi ◽  
Waleed AlAmeri

Abstract Polymer flooding is one of the most commonly used chemical EOR methods. Conventionally, this technique was believed to improve macroscopic sweep efficiency by sweeping only bypassed oil. Nevertheless, recently it has been found that polymers exhibiting viscoelastic behavior in the porous medium can also improve microscopic displacement efficiency resulting in higher additional oil recovery. Therefore, an accurate prediction of the complex rheological response of polymers is crucial to obtain a proper estimation of incremental oil to polymer flooding. In this paper, a novel viscoelastic model is proposed to comprehensively analyze the polymer rheological behavior in porous media. The proposed viscoelastic model is considered an extension of the unified apparent viscosity model provided in the literature and is termed as extended unified viscosity model (E-UVM). The main advantage of the proposed model is its ability to capture the polymer mechanical degradation at ultimate shear rates primarily observed near wellbores. Furthermore, the fitting parameters used in the model were correlated to rock and polymer properties, significantly reducing the need for time-consuming coreflooding tests for future polymer screening works. Moreover, the extended viscoelastic model was implemented in MATLAB Reservoir Simulation Toolbox (MRST) and verified against the original shear model existing in the simulator. It was found that implementing the viscosity model in MRST might be more accurate and practical than the original method. In addition, the comparison between various viscosity models proposed earlier and E-UVM in the reservoir simulator revealed that the latter model could yield more reliable oil recovery predictions since it accommodates the mechanical degradation of polymers. This study presents a novel viscoelastic model that is more comprehensive and representative as opposed to other models in the literature.


Blood ◽  
1987 ◽  
Vol 70 (5) ◽  
pp. 1437-1442
Author(s):  
E Bastida ◽  
G Escolar ◽  
A Ordinas ◽  
JJ Sixma

Fibronectin (FN) plays a role in several adhesion mediated functions including the interaction of platelets with subendothelium. We investigated the role of plasma FN in platelet adhesion and platelet thrombus formation under flow conditions. We used two different perfusion models: the annular chamber with alpha-chymotrypsin-treated rabbit vessel segments, and the flat chamber with coverslips coated with fibrillar purified human collagen type III. Perfusates consisted of washed platelets and washed RBCs, suspended in normal or FN-depleted plasma. Perfusions were carried out for ten minutes at shear rates of 300 or 1,300 s-1. Platelet deposition and thrombus dimensions were evaluated morphometrically by a computerized system. We found that depletion of plasma fibronectin significantly reduced the percentage of total coverage surface and percentage of platelet thrombus, at both shear rates studied, and in both perfusion systems (P less than .01) (P less than .01). The dimensions of the platelet thrombi formed in perfusions at high shear rate were also significantly reduced in perfusions carried out with FN depleted plasma (P less than .01). Addition of purified FN to FN-depleted perfusates restored all values to those measured in the control perfusions. These results indicate that plasma FN is required for platelet aggregate and thrombus formation following adhesion under flow conditions.


Blood ◽  
2006 ◽  
Vol 109 (6) ◽  
pp. 2424-2429 ◽  
Author(s):  
Anil K. Chauhan ◽  
Janka Kisucka ◽  
Colin B. Lamb ◽  
Wolfgang Bergmeier ◽  
Denisa D. Wagner

Abstract von Willebrand factor (VWF) protects factor VIII (FVIII) from proteolysis and mediates the initial contact of platelets with the injured vessel wall, thus playing an important role in hemostasis and thrombosis. VWF is crucial for the formation of occlusive thrombi at arterial shear rates. However, with only a few conflicting studies published, the role of VWF in venous thrombosis is still unclear. Using gene-targeted mice, we show that in ferric chloride–injured veins platelet adhesion to subendothelium is decreased and thrombus growth is impaired in VWF−/− mice when compared with wild type (WT). We also observed increased embolization in the VWF−/− mice, which was due to lower FVIII levels in these mice as recombinant factor VIII (r-FVIII) restored thrombus stability. Despite normalization of blood clotting time and thrombus stability after r-FVIII infusion, the VWF−/− venules did not occlude. Transgenic platelets lacking the VWF receptor GPIbα extracellular domain showed decreased adhesion to injured veins. But, after a delay, all the injured venules occluded in these transgenic mice. Thus, VWF likely uses other adhesion receptors besides GPIbα in thrombus growth under venous shear conditions. Our studies document crucial roles for VWF and FVIII in experimental thrombosis under venous flow conditions in vivo.


Sign in / Sign up

Export Citation Format

Share Document