scholarly journals Application Solid Laser-Sintered or Machined Ti6Al4V Alloy in Manufacturing of Dental Implants and Dental Prosthetic Restorations According to Dentistry 4.0 Concept

Processes ◽  
2020 ◽  
Vol 8 (6) ◽  
pp. 664 ◽  
Author(s):  
Leszek A. Dobrzański ◽  
Lech B. Dobrzański ◽  
Anna Achtelik-Franczak ◽  
Joanna Dobrzańska

This paper presents a comparison of the impact of milling technology in the computer numerically controlled (CNC) machining centre and selective laser sintering (SLS) and on the structure and properties of solid Ti6Al4V alloy. It has been shown that even small changes in technological conditions in the SLS manufacturing variant significantly affect changes from two to nearly two and a half times in tensile and bending strengths. Both the tensile and bending strength obtained in the most favourable manufacturing variant by the SLS method is over 25% higher than in the case of cast materials subsequently processed by milling. Plug-and-play SLS conditions provide about 60% of the possibilities. Structural, tribological and electrochemical tests were carried out. In vitro biological tests using osteoblasts confirm the good tendency for the proliferation of live cells on the substrate manufactured under the most favourable SLS conditions. The use of SLS additive technology for the manufacturing of dental implants and abutments made of Ti6Al4V alloy in combination with the digitisation of dental diagnostics and computer-aided design and manufacture of computer-aided design/manufacturing (CAD/CAM) following the idea of Dentistry 4.0 is the best choice of technology for manufacturing of prosthetic and implant devices used in dentistry.

2021 ◽  
Author(s):  
RG Fonseca ◽  
RC Peńa ◽  
R Simóes ◽  
AC Ramos ◽  
LN Dovigo

SUMMARY Little is known about the impact of bleaching on the optical properties of computer-aided design and computer-aided manufactured (CAD-CAM) monolithic materials. The aim of the present study was to evaluate the effect of one session of in-office bleaching on stain removal, staining susceptibility, translucency, and whiteness variations of CADCAM monolithic materials. Disks were fabricated from Lava Ultimate (LU), Vita Enamic (VE), Vita Suprinity (VS), and IPS e.max CAD (IPS). A spectrophotometer was used to register Commission Internationale de l’Eclairage L*a*b* coordinates. For stain removal, 80 specimens from each material were assessed at baseline (R0) and after immersion in deionized water or coffee for 365 days followed or not by bleaching with 40% hydrogen peroxide (R1). For staining susceptibility, 80 specimens from each material were analyzed at baseline (R0’), and after having been bleached or not and immersed in deionized water or coffee (R1’). Both analyses were calculated as the color difference (ΔE00) between R1-R0 and R1’-R0’, respectively. Differences in translucency (ΔTP00) and whiteness (ΔWID) between R1-R0 and R1’-R0’ were also calculated. Data were analyzed by three-way ANOVA and the Games-Howell post hoc test (α=0.05). Clinical significance was based on 50%:50% perceptibility and acceptability thresholds for ΔE00, ΔTP00 and ΔWID, respectively. Surfaces were analyzed by scanning electron microscopy. Coffee increased ΔE00 in LU, VE, and VS, and decreased their translucency and whiteness, whereas the IPS had only its whiteness affected. Bleaching after immersion in coffee decreased ΔE00 in LU and VE, and increased translucency and whiteness of LU, VE, and VS. No effect was observed on IPS. Bleaching before immersion in coffee decreased translucency of LU, but within the acceptable interval, while VE exhibited lower ΔE00, and became more translucent and less dark. Both VS and IPS were not affected. One session of in-office bleaching benefited optical properties of the previously stained LU, VE, and VS, without increasing their susceptibility to staining or adversely providing clinically unacceptable variations in their translucency and whiteness. All variations exhibited by the IPS were below the perceptible threshold.


Author(s):  
Fariborz Vafaei ◽  
Alireza Izadi ◽  
Samaneh Abbasi ◽  
Maryam Farhadian ◽  
Zahra Bagheri

Objectives: This study aimed to compare the optical properties of Zolid FX, Katana UTML, and lithium disilicate laminate veneers. Materials and Methods: In this in-vitro experimental study, the maxillary left lateral incisor of a phantom received a laminate veneer preparation. An impression was made, and a die was fabricated using dental stone. The die was scanned using a computer-aided design/computer-aided manufacturing scanner. Ten dies were fabricated from each of the A1, A2, and A3 shades of composite resin. Laminate veneers were fabricated using A1 shade of Katana UTML, Zolid FX, and IPS e.max CAD ceramics (n=10) and placed on composite abutments using bleach and white colors of trial insertion paste (TIP). The optical properties were measured at the incisal, middle, and cervical thirds using a spectrophotometer. Data were analyzed using three-way analysis of variance and Tukey’s test. Results: The effect of laminate material on the L*, a*, and b* parameters was significant in all areas (P<0.001), except for the L* parameter in the middle and cervical thirds. All color parameters were affected by TIP color in all three regions in most samples (P<0.05). The effect of composite abutment shade was also significant in most cases (P<0.05). The effect of laminate material, abutment shade, and TIP color on the b* parameter was significant (P<0.001). The L* parameter was almost the same in the two zirconia and lithium disilicate ceramic groups. Conclusion: The composite abutment shade, TIP color, and laminate material should be carefully selected to achieve optimal aesthetics in laminate veneers.


1987 ◽  
Vol 31 (2) ◽  
pp. 214-217
Author(s):  
Douglas H. Harris ◽  
Steven M. Casey

A methodology for measuring the organizational effectiveness of computer-aided design (CAD) was developed and applied. A total of 295 of the 500 most frequent users of CAD in a major aerospace company provided data for the study. User-CAD effectiveness was found to be influenced by 43 major factors and 145 specific system and organizational issues. The 43 factors were classified into the following categories: system functions, system hardware, working environment, system reliability and consistency, user access, user support and training, and system administration. Indexes of User-CAD Effectiveness (UE) and System Availability and Reliability (AR) were combined into an Index of CAD Organizational Effectiveness (OE). Through the application of these methods and indexes, CAD system and organizational deficiencies can be diagnosed, potential high-payoff improvements can be identified, and the impact of developmental efforts can be assessed.


Author(s):  
David Veisz ◽  
Essam Z. Namouz ◽  
Shraddha Joshi ◽  
Joshua D Summers

AbstractThis paper presents a preliminary comparison between the role of computer-aided design (CAD) and sketching in engineering through a case study of a senior design project and interviews with industry and academia. The design team consisted of four senior level mechanical engineering students each with less than 1 year of professional experience are observed while completing an industry sponsored mechanical engineering capstone design project across a 17 week semester. Factors investigated include what CAD tools are used, when in the design process they are implemented, the justification for their use from the students' perspectives, the actual knowledge gained from their use, the impact on the final designed artifact, and the contributions of any sketches generated. At each design step, comparisons are made between CAD and sketching. The students implemented CAD tools at the onset of the project, generally failing to realize gains in design efficiency or effectiveness in the early conceptual phases of the design process. As the design became more concrete, the team was able to recognize clear gains in both efficiency and effectiveness through the use of computer assisted design programs. This study is augmented by interviews with novice and experienced industry users and academic instructors to align the trends observed in the case study with industry practice and educational emphasis. A disconnect in the perceived capability of CAD tools was found between novice and experienced user groups. Opinions on the importance of sketching skills differed between novice educators and novice industry professionals, suggesting that there is a change of opinion as to the importance of sketching formed when recent graduates transition from academia to industry. The results suggest that there is a need to emphasize the importance of sketching and a deeper understanding as to the true utility of CAD tools at each stage of the design process.


Sign in / Sign up

Export Citation Format

Share Document