ti6al4v alloy
Recently Published Documents


TOTAL DOCUMENTS

1101
(FIVE YEARS 449)

H-INDEX

50
(FIVE YEARS 13)

2022 ◽  
Vol 26 (1) ◽  
Author(s):  
Paula Zwicker ◽  
Thomas Schmidt ◽  
Melanie Hornschuh ◽  
Holger Lode ◽  
Axel Kramer ◽  
...  

Abstract Aim Periprosthetic joint infections are a devastating complication after arthroplasty, leading to rejection of the prosthesis. The prevention of septic loosening may be possible by an antimicrobial coating of the implant surface. Poly (hexamethylene) biguanide hydrochloride [PHMB] seems to be a suitable antiseptic agent for this purpose since previous studies revealed a low cytotoxicity and a long-lasting microbicidal effect of Ti6Al4V alloy coated with PHMB. To preclude an excessive activation of the immune system, possible inflammatory effects on macrophages upon contact with PHMB-coated surfaces alone and after killing of S. epidermidis and P. aeruginosa are analyzed. Methods THP-1 monocytes were differentiated to M0 macrophages by phorbol 12-myristate 13-acetate and seeded onto Ti6Al4V surfaces coated with various amounts of PHMB. Next to microscopic immunofluorescence analysis of labeled macrophages after adhesion on the coated surface, measurement of intracellular reactive oxygen species and analysis of cytokine secretion at different time points without and with previous bacterial contamination were conducted. Results No influence on morphology of macrophages and only slight increases in iROS generation were detected. The cytokine secretion pattern depends on the surface treatment procedure and the amount of adsorbed PHMB. The PHMB coating resulted in a high reduction of viable bacteria, resulting in no significant differences in cytokine secretion as reaction to coated surfaces with and without bacterial burden. Conclusion Ti6Al4V specimens after alkaline treatment followed by coating with 5–7 μg PHMB and specimens treated with H2O2 before PHMB-coating (4 μg) had the smallest influence on the macrophage phienotype and thus are considered as the surface with the best cytocompatibility to macrophages tested in the present study.


2022 ◽  
pp. 163574
Author(s):  
Zhenxue Zhang ◽  
Yuejiao Zhang ◽  
Xiao Tao ◽  
Ke Liu ◽  
Andrew Burns ◽  
...  
Keyword(s):  

Materials ◽  
2021 ◽  
Vol 15 (1) ◽  
pp. 252
Author(s):  
Mariusz Hasiak ◽  
Beata Sobieszczańska ◽  
Amadeusz Łaszcz ◽  
Michał Biały ◽  
Jacek Chęcmanowski ◽  
...  

Microstructure, mechanical properties, corrosion resistance, and biocompatibility were studied for rapidly cooled 3 mm rods of Zr40Ti15Cu10Ni10Be25, Zr50Ti5Cu10Ni10Be25, and Zr40Ti15Cu10Ni5Si5Be25 (at.%) alloys, as well as for the reference 316L stainless steel and Ti-based Ti6Al4V alloy. Microstructure investigations confirm that Zr-based bulk metallic samples exhibit a glassy structure with minor fractions of crystalline phases. The nanoindentation tests carried out for all investigated composite materials allowed us to determine the mechanical parameters of individual phases observed in the samples. The instrumental hardness and elastic to total deformation energy ratio for every single phase observed in the manufactured Zr-based materials are higher than for the reference materials (316L stainless steel and Ti6Al4V alloy). A scratch tester used to determine the wear behavior of manufactured samples and reference materials revealed the effect of microstructure on mechanical parameters such as residual depth, friction force, and coefficient of friction. Electrochemical investigations in simulated body fluid performed up to 120 h show better or comparable corrosion resistance of Zr-based bulk metallic glasses in comparison with 316L stainless steel and Ti6Al4V alloy. The fibroblasts viability studies confirm the good biocompatibility of the produced materials. All obtained results show that fabricated biocompatible Zr-based materials are promising candidates for biomedical implants that require enhanced mechanical properties.


Materials ◽  
2021 ◽  
Vol 14 (24) ◽  
pp. 7641
Author(s):  
Jesús Andrés Naranjo ◽  
Valentín Miguel ◽  
Juana Coello ◽  
María Carmen Manjabacas ◽  
Alberto Martínez-Martínez ◽  
...  

Heat-assisted single point incremental forming or HA-SPIF has a great potential for producing one-piece batches of hard-to-form materials such as Ti6Al4V alloy for medical and aeronautical applications. One of the limitations of the process is the difficulty in achieving a reasonable surface finish, which makes essential the characterization of the tribological process in the tool–sheet contact. In fact, not much work can be found at this point in literature. In this research, a novel procedure for evaluating the adhesion on the tool surface is proposed and the influence of the temperature is determined. The surface finish of parts is analyzed, and the changes promoted by HA-SPIF appearing in the morphology of the external surface layer are characterized by SEM.


Materials ◽  
2021 ◽  
Vol 14 (23) ◽  
pp. 7408
Author(s):  
Kishan Fuse ◽  
Arrown Dalsaniya ◽  
Dhananj Modi ◽  
Jay Vora ◽  
Danil Yurievich Pimenov ◽  
...  

Titanium and its alloys exhibit numerous uses in aerospace, automobile, biomedical and marine industries because of their enhanced mechanical properties. However, the machinability of titanium alloys can be cumbersome due to their lower density, high hardness, low thermal conductivity, and low elastic modulus. The wire electrical discharge machining (WEDM) process is an effective choice for machining titanium and its alloys due to its unique machining characteristics. The present work proposes multi-objective optimization of WEDM on Ti6Al4V alloy using a fuzzy integrated multi-criteria decision-making (MCDM) approach. The use of MCDM has become an active area of research due to its proven ability to solve complex problems. The novelty of the present work is to use integrated fuzzy analytic hierarchy process (AHP) and fuzzy technique for order preference by similarity to ideal situation (TOPSIS) to optimize the WEDM process. The experiments were systematically conducted adapting the face-centered central composite design approach of response surface methodology. Three independent factors—pulse-on time (Ton), pulse-off time (Toff), and current—were chosen, each having three levels to monitor the process response in terms of cutting speed (VC), material removal rate (MRR), and surface roughness (SR). To assess the relevance and significance of the models, an analysis of variance was carried out. The optimal process parameters after integrating fuzzy AHP coupled with fuzzy TOPSIS approach found were Ton = 40 µs, Toff = 15 µs, and current = 2A.


Sign in / Sign up

Export Citation Format

Share Document