scholarly journals Permalloy-Based Thin Film Structures: Magnetic Properties and the Giant Magnetoimpedance Effect in the Temperature Range Important for Biomedical Applications

Sensors ◽  
2017 ◽  
Vol 17 (8) ◽  
pp. 1900 ◽  
Author(s):  
Anna A. Chlenova ◽  
Alexey A. Moiseev ◽  
Mikhail S. Derevyanko ◽  
Aleksandr V. Semirov ◽  
Vladimir N. Lepalovsky ◽  
...  
2021 ◽  
Vol 63 (9) ◽  
pp. 1290
Author(s):  
Г.В. Курляндская ◽  
А.П. Сафронов ◽  
С.В. Щербинин ◽  
И.В. Бекетов ◽  
Ф.А. Бляхман ◽  
...  

This work describes the possibility of fabrication of the large batches of magnetic nanoparticles using electrophysical methods of electric explosion of the wire, laser target evaporation and spark discharge. Bioapplications of nanoparticles require the production of magnetic materials in the form of stabilized aqueous suspensions or hydrogels with magnetic fillers; therefore, some details of the synthesis of these materials and their certification are discussed. The peculiarities of interaction of magnetic nanoparticles with biological systems, the problem of biocompatibility, the possibility of using ferrogel substrates for the needs of cell technologies and regenerative medicine, as well as implication of biomimetics in the development of magnetic biosensors are considered. The results of the analysis of a number of different biological experiments carried out with suspensions of various types, obtained based on the same batch of MNPs are presented. An analysis of examples of magnetic biodetection and existing theoretical approaches will make it possible to assess the prospects of this scientific direction for the creation of highly sensitive thin film sensors based on the giant magnetoimpedance effect for biomedical applications


Sensors ◽  
2019 ◽  
Vol 19 (14) ◽  
pp. 3060
Author(s):  
Alberto Moya ◽  
Diego Archilla ◽  
Elena Navarro ◽  
Antonio Hernando ◽  
Pilar Marín

Co-based amorphous microwires presenting the giant magnetoimpedance effect are proposed as sensing elements for high sensitivity biosensors. In this work we report an experimental method for contactless detection of stress, temperature, and liquid concentration with application in medical sensors using the giant magnetoimpedance effect on microwires in the GHz range. The method is based on the scattering of electromagnetic microwaves by FeCoSiB amorphous metallic microwires. A modulation of the scattering parameter is achieved by applying a magnetic bias field that tunes the magnetic permeability of the ferromagnetic microwires. We demonstrate that the OFF/ON switching of the bias activates or cancels the amorphous ferromagnetic microwires (AFMW) antenna behavior. We show the advantages of measuring the performing time dependent frequency sweeps. In this case, the AC-bias modulation of the scattering coefficient versus frequency may be clearly appreciated. Furthermore, this modulation is enhanced by using arrays of microwires with an increasing number of individual microwires according to the antenna radiation theory. Transmission spectra show significant changes in the range of 3 dB for a relatively weak magnetic field of 15 Oe. A demonstration of the possibilities of the method for biomedical applications is shown by means of wireless temperature detector from 0 to 100 °C.


2014 ◽  
Vol 28 (3) ◽  
pp. 813-822 ◽  
Author(s):  
A. Zhukov ◽  
A. Talaat ◽  
M. Ipatov ◽  
J. J. del Val ◽  
L. Gonzalez-Legarreta ◽  
...  

Sensors ◽  
2020 ◽  
Vol 20 (6) ◽  
pp. 1558 ◽  
Author(s):  
Lorena Gonzalez-Legarreta ◽  
Paula Corte-Leon ◽  
Valentina Zhukova ◽  
Mihail Ipatov ◽  
Juan Maria Blanco ◽  
...  

Magnetic microwires can present excellent soft magnetic properties and a giant magnetoimpedance effect. In this paper, we present our last results on the effect of postprocessing allowing optimization of the magnetoimpedance effect in Co-rich microwires suitable for magnetic microsensor applications. Giant magnetoimpedance effect improvement was achieved either by annealing or stress-annealing. Annealed Co-rich presents rectangular hysteresis loops. However, an improvement in magnetoimpedance ratio is observed at fairly high annealing temperatures over a wide frequency range. Application of stress during annealing at moderate values of annealing temperatures and stress allows for a remarkable decrease in coercivity and increase in squareness ratio and further giant magnetoimpedance effect improvement. Stress-annealing, carried out at sufficiently high temperatures and/or stress allowed induction of transverse magnetic anisotropy, as well as magnetoimpedance effect improvement. Enhanced magnetoimpedance ratio values for annealed and stress-annealed samples and frequency dependence of the magnetoimpedance are discussed in terms of the radial distribution of the magnetic anisotropy. Accordingly, we demonstrated that the giant magnetoimpedance effect of Co-rich microwires can be tailored by controlling the magnetic anisotropy of Co-rich microwires, using appropriate thermal treatment.


2017 ◽  
Vol 121 (12) ◽  
pp. 124501 ◽  
Author(s):  
G. L. S. Vilela ◽  
J. G. Monsalve ◽  
A. R. Rodrigues ◽  
A. Azevedo ◽  
F. L. A. Machado

2017 ◽  
Vol 86 ◽  
pp. 15-19 ◽  
Author(s):  
A. Chizhik ◽  
V. Vega ◽  
Abd El-Moez A. Mohamed ◽  
V.M. Prida ◽  
T. Sánchez ◽  
...  

Sign in / Sign up