scholarly journals Evaluation of Inertial Sensor Data by a Comparison with Optical Motion Capture Data of Guitar Strumming Gestures

Sensors ◽  
2020 ◽  
Vol 20 (19) ◽  
pp. 5722
Author(s):  
Sérgio Freire ◽  
Geise Santos ◽  
Augusto Armondes ◽  
Eduardo A. L. Meneses ◽  
Marcelo M. Wanderley

Computing technologies have opened up a myriad of possibilities for expanding the sonic capabilities of acoustic musical instruments. Musicians nowadays employ a variety of rather inexpensive, wireless sensor-based systems to obtain refined control of interactive musical performances in actual musical situations like live music concerts. It is essential though to clearly understand the capabilities and limitations of such acquisition systems and their potential influence on high-level control of musical processes. In this study, we evaluate one such system composed of an inertial sensor (MetaMotionR) and a hexaphonic nylon guitar for capturing strumming gestures. To characterize this system, we compared it with a high-end commercial motion capture system (Qualisys) typically used in the controlled environments of research laboratories, in two complementary tasks: comparisons of rotational and translational data. For the rotations, we were able to compare our results with those that are found in the literature, obtaining RMSE below 10° for 88% of the curves. The translations were compared in two ways: by double derivation of positional data from the mocap and by double integration of IMU acceleration data. For the task of estimating displacements from acceleration data, we developed a compensative-integration method to deal with the oscillatory character of the strumming, whose approximative results are very dependent on the type of gestures and segmentation; a value of 0.77 was obtained for the average of the normalized covariance coefficients of the displacement magnitudes. Although not in the ideal range, these results point to a clearly acceptable trade-off between the flexibility, portability and low cost of the proposed system when compared to the limited use and cost of the high-end motion capture standard in interactive music setups.

Author(s):  
Sol Lim ◽  
Andrea Case ◽  
Clive D’Souza

This study examined interactions between inertial sensor (IS) performance and physical task demand on posture kinematics in a two-handed force exertion task. Fifteen male individuals participated in a laboratory experiment that involved exerting a two-handed isometric horizontal force on an instrumented height-adjustable handle. Physical task demand was operationalized by manipulating vertical handle height, target force magnitude, and force direction. These factors were hypothesized to influence average estimates of torso flexion angle measured using inertial sensors and an optical motion capture (MC) system, as well as the root mean squared errors (RMSE) between instrumentation computed over a 3s interval of the force exertion task. Results indicate that lower handle heights and higher target force levels were associated with increased torso and pelvic flexion in both, push and pull exertions. Torso flexion angle estimates obtained from IS and MC did not differ significantly. However, RMSE increased with target force intensity suggesting potential interactive effects between measurement error and physical task demand.


2014 ◽  
Vol 568-570 ◽  
pp. 676-680
Author(s):  
Si Xi Chen ◽  
Shu Chen

The application of digital technology on the protection of intangible cultural heritage is a major topic of research in recent years. The motion capture technology of protection will gradually replace the traditional recording methods such as texts, pictures and videos. It is valuable to build a high-fidelity, high-modular and low-cost digital platform for choreographic data collection and extended application. This paper studies the intangible cultural heritage of Quanzhou breast-clapping dance, one of the most famous choreographic intangible cultural heritages from China with standard optical motion capture method. The data are acquiring and processing after the dance motion capture, we binds the motion data and three-dimensional model using Motion Builder and build digital demonstration platform base on an OGRE engine to display the movements. The viewer can view at any angle and distance. The system can be easily applied in motion intangible cultural heritages protection project. Furthermore, the system can be provided versatile motion data for additional use.


Author(s):  
Muhamad Nurul Hisyam Yunus ◽  
Mohd Hafiidz Jaafar ◽  
Ahmad Sufril Azlan Mohamed ◽  
Nur Zaidi Azraai ◽  
Md. Sohrab Hossain

Work-related musculoskeletal disorders (WMSDs) are among the most common disorders in any work sector and industry. Ergonomic risk assessment can reduce the risk of WMSDs. Motion capture that can provide accurate and real-time quantitative data has been widely used as a tool for ergonomic risk assessment. However, most ergonomic risk assessments that use motion capture still depend on the traditional ergonomic risk assessment method, focusing on qualitative data. Therefore, this article aims to provide a view on the ergonomic risk assessment and apply current motion capture technology to understand classical mechanics of physics that include velocity, acceleration, force, and momentum in ergonomic risk assessment. This review suggests that using motion capture technologies with kinetic and kinematic variables, such as velocity, acceleration, and force, can help avoid inconsistency and develop more reliable results in ergonomic risk assessment. Most studies related to the physical measurement conducted with motion capture prefer to use non-optical motion capture because it is a low-cost system and simple experimental setup. However, the present review reveals that optical motion capture can provide more accurate data.


Sensors ◽  
2021 ◽  
Vol 21 (14) ◽  
pp. 4799
Author(s):  
Calvin Young ◽  
Sarah DeDecker ◽  
Drew Anderson ◽  
Michele L. Oliver ◽  
Karen D. Gordon

Wrist motion provides an important metric for disease monitoring and occupational risk assessment. The collection of wrist kinematics in occupational or other real-world environments could augment traditional observational or video-analysis based assessment. We have developed a low-cost 3D printed wearable device, capable of being produced on consumer grade desktop 3D printers. Here we present a preliminary validation of the device against a gold standard optical motion capture system. Data were collected from 10 participants performing a static angle matching task while seated at a desk. The wearable device output was significantly correlated with the optical motion capture system yielding a coefficient of determination (R2) of 0.991 and 0.972 for flexion/extension (FE) and radial/ulnar deviation (RUD) respectively (p < 0.0001). Error was similarly low with a root mean squared error of 4.9° (FE) and 3.9° (RUD). Agreement between the two systems was quantified using Bland–Altman analysis, with bias and 95% limits of agreement of 3.1° ± 7.4° and −0.16° ± 7.7° for FE and RUD, respectively. These results compare favourably with current methods for occupational assessment, suggesting strong potential for field implementation.


Author(s):  
Kodai Kitagawa ◽  
Ibai Gorordo Fernandez ◽  
Takayuki Nagasaki ◽  
Sota Nakano ◽  
Mitsumasa Hida ◽  
...  

Assistive motion for sit-to-stand causes lower back pain (LBP) among caregivers. Considering previous studies that showed that foot position adjustment could reduce lumbar load during assistive motion for sit-to-stand, quantitative monitoring of and instructions on foot position could contribute toward reducing LBP among caregivers. The present study proposes and evaluates a new method for the quantitative measurement of foot position during assistive motion for sit-to-stand using a few wearable sensors that are not limited to the measurement area. The proposed method measures quantitative foot position (anteroposterior and mediolateral distance between both feet) through a machine learning technique using features obtained from only a single inertial sensor on the trunk and shoe-type force sensors. During the experiment, the accuracy of the proposed method was investigated by comparing the obtained values with those from an optical motion capture system. The results showed that the proposed method produced only minor errors (less than 6.5% of body height) when measuring foot position during assistive motion for sit-to-stand. Furthermore, Bland–Altman plots suggested no fixed errors between the proposed method and the optical motion capture system. These results suggest that the proposed method could be utilized for measuring foot position during assistive motion for sit-to-stand.


Proceedings ◽  
2020 ◽  
Vol 49 (1) ◽  
pp. 10 ◽  
Author(s):  
Tomohito Wada ◽  
Ryu Nagahara ◽  
Sam Gleadhill ◽  
Tatsuro Ishizuka ◽  
Hayato Ohnuma ◽  
...  

The purpose of this study was to elucidate pelvic orientation angles using a single lower back-mounted inertial sensor during sprinting. A single inertial sensor was attached to each sprinter’s lower back, used to measure continuous pelvic movements including pelvic obliquity (roll), anterior-posterior tilt (pitch) and rotation (yaw) during sprinting from a straight to bend section. The pelvic orientation angles were estimated with the three-dimensional sensor orientation using a sensor fusion algorithm. Absolute angles derived from the sensor were compared with angles obtained from an optical motion capture system over a 15 m length. The root mean squared error between the sensor and motion capture data were 4.1° for roll, 2.8° for pitch and 3.6° for yaw. Therefore, the sensor was comparable to the motion capture system for tracking pelvic angle changes. The inertial sensor is now supported as a valid tool to measure movements of the pelvis during sprinting.


Sensors ◽  
2021 ◽  
Vol 21 (7) ◽  
pp. 2480
Author(s):  
Isidoro Ruiz-García ◽  
Ismael Navarro-Marchal ◽  
Javier Ocaña-Wilhelmi ◽  
Alberto J. Palma ◽  
Pablo J. Gómez-López ◽  
...  

In skiing it is important to know how the skier accelerates and inclines the skis during the turn to avoid injuries and improve technique. The purpose of this pilot study with three participants was to develop and evaluate a compact, wireless, and low-cost system for detecting the inclination and acceleration of skis in the field based on inertial measurement units (IMU). To that end, a commercial IMU board was placed on each ski behind the skier boot. With the use of an attitude and heading reference system algorithm included in the sensor board, the orientation and attitude data of the skis were obtained (roll, pitch, and yaw) by IMU sensor data fusion. Results demonstrate that the proposed IMU-based system can provide reliable low-drifted data up to 11 min of continuous usage in the worst case. Inertial angle data from the IMU-based system were compared with the data collected by a video-based 3D-kinematic reference system to evaluate its operation in terms of data correlation and system performance. Correlation coefficients between 0.889 (roll) and 0.991 (yaw) were obtained. Mean biases from −1.13° (roll) to 0.44° (yaw) and 95% limits of agreements from 2.87° (yaw) to 6.27° (roll) were calculated for the 1-min trials. Although low mean biases were achieved, some limitations arose in the system precision for pitch and roll estimations that could be due to the low sampling rate allowed by the sensor data fusion algorithm and the initial zeroing of the gyroscope.


Sign in / Sign up

Export Citation Format

Share Document