scholarly journals Mask-Type Sensor for Pulse Wave and Respiration Measurements and Eye Blink Detection

Sensors ◽  
2021 ◽  
Vol 21 (14) ◽  
pp. 4895
Author(s):  
Thanh-Vinh Nguyen ◽  
Masaaki Ichiki

This paper reports on a mask-type sensor for simultaneous pulse wave and respiration measurements and eye blink detection that uses only one sensing element. In the proposed sensor, a flexible air bag-shaped chamber whose inner pressure change can be measured by a microelectromechanical system-based piezoresistive cantilever was used as the sensing element. The air bag-shaped chamber is fabricated by wrapping a sponge pad with plastic film and polyimide tape. The polyimide tape has a hole to which the substrate with the piezoresistive cantilever adheres. By attaching the sensor device to a mask where it contacts the nose of the subject, the sensor can detect the pulses and eye blinks of the subject by detecting the vibration and displacement of the nose skin caused by these physiological parameters. Moreover, the respiration of the subject causes pressure changes in the space between the mask and the face of the subject as well as slight vibrations of the mask. Therefore, information about the respiration of the subject can be extracted from the sensor signal using either the low-frequency component (<1 Hz) or the high-frequency component (>100 Hz). This paper describes the sensor fabrication and provides demonstrations of the pulse wave and respiration measurements as well as eye blink detection using the fabricated sensor.

Sensors ◽  
2019 ◽  
Vol 19 (22) ◽  
pp. 4942 ◽  
Author(s):  
Thanh-Vinh Nguyen ◽  
Masaaki Ichiki

The continuous measurements of vital signs (body temperature, blood pressure, pulse wave, and respiration rate) are important in many applications across various fields, including healthcare and sports. To realize such measurements, wearable devices that cause minimal discomfort to the wearers are highly desired. Accordingly, a device that can measure multiple vital signs simultaneously using a single sensing element is important in order to reduce the number of devices attached to the wearer’s body, thereby reducing user discomfort. Thus, in this study, we propose a device with a microelectromechanical systems (MEMS)-based pressure sensor that can simultaneously measure the blood pulse wave and respiration rate using only one sensing element. In particular, in the proposed device, a thin silicone tube, whose inner pressure can be measured via a piezoresistive cantilever, is attached to the nose pad of a pair of eyeglasses. On wearing the eyeglasses, the tube of sensor device is in contact with the area above the angular artery and nasal cavity of the subject, and thus, both pulse wave and breath of the subject cause the tube’s inner pressure to change. We experimentally show that it is possible to extract information related to pulse wave and respiration as the low-frequency and high-frequency components of the sensor signal, respectively.


Sensors ◽  
2020 ◽  
Vol 20 (4) ◽  
pp. 1052 ◽  
Author(s):  
Thanh-Vinh Nguyen ◽  
Yuya Mizuki ◽  
Takuya Tsukagoshi ◽  
Tomoyuki Takahata ◽  
Masaaki Ichiki ◽  
...  

This paper reports on a microelectromechanical systems (MEMS)-based sensor for pulse wave measurement. The sensor consists of an air chamber with a thin membrane and a 300-nm thick piezoresistive cantilever placed inside the chamber. When the membrane of the chamber is in contact with the skin above a vessel of a subject, the pulse wave of the subject causes the membrane to deform, leading to a change in the chamber pressure. This pressure change results in bending of the cantilever and change in the resistance of the cantilever, hence the pulse wave of the subject can be measured by monitoring the resistance of the cantilever. In this paper, we report the sensor design and fabrication, and demonstrate the measurement of the pulse wave using the fabricated sensor. Finally, measurement of the pulse wave velocity (PWV) is demonstrated by simultaneously measuring pulse waves at two points using the two fabricated sensor devices. Furthermore, the effect of breath holding on PWV is investigated. We showed that the proposed sensor can be used to continuously measure the PWV for each pulse, which indicates the possibility of using the sensor for continuous blood pressure measurement.


2006 ◽  
Vol 321-323 ◽  
pp. 968-971
Author(s):  
Won Su Park ◽  
Sang Woo Choi ◽  
Joon Hyun Lee ◽  
Kyeong Cheol Seo ◽  
Joon Hyung Byun

For improving quality of a carbon fiber reinforced composite material (CFRP) by preventing defects such as delamination and void, it should be inspected in fabrication process. Novel non-contacting evaluation technique is required because the transducer should be contacted on the CFRP in conventional ultrasonic technique during the non-destructive evaluation and these conventional contact techniques can not be applied in a novel fiber placement system. For the non-destructive evaluation of delamination in CFRP, various methods for the generation and reception of laser-generated ultrasound are applied using piezoelectric transducer, air-coupled transducer, wavelet transform technique etc. The high frequency component of laser-generated guided wave received with piezoelectric sensor disappeared after propagating through delamination region. Air-coupled transducer was tried to be adopted in reception of laser-generated guided wave generated by using linear slit array in order to generate high frequency guided wave with a frequency of 1.1 MHz. Nevertheless, it was failed to receive high frequency guided wave in using air-coupled transducer and linear slit array. Transmitted laser-generated ultrasonic wave was received on back-wall and its frequency was analyzed to establish inspecting technique to detect delamination by non-contact ultrasonic method. In a frequency spectrum analysis, intensity ratio of low frequency and center frequency was approvable parameter to detect delamination.


Author(s):  
Hakaru Tamukoh ◽  
Hideaki Kawano ◽  
Noriaki Suetake ◽  
Masatoshi Sekine ◽  
Byungki Cha ◽  
...  

Author(s):  
Dang-Khoa Tran ◽  
Thanh-Hai Nguyen ◽  
Thanh-Nghia Nguyen

In the electroencephalography (EEG) study, eye blinks are a commonly known type of ocular artifact that appears most frequently in any EEG measurement. The artifact can be seen as spiking electrical potentials in which their time-frequency properties are varied across individuals. Their presence can negatively impact various medical or scientific research or be helpful when applying to brain-computer interface applications. Hence, detecting eye-blink signals is beneficial for determining the correlation between the human brain and eye movement in this paper. The paper presents a simple, fast, and automated eye-blink detection algorithm that did not require user training before algorithm execution. EEG signals were smoothed and filtered before eye-blink detection. We conducted experiments with ten volunteers and collected three different eye-blink datasets over three trials using Emotiv EPOC+ headset. The proposed method performed consistently and successfully detected spiking activities of eye blinks with a mean accuracy of over 96%.


2002 ◽  
Vol 282 (3) ◽  
pp. H973-H976 ◽  
Author(s):  
Nobuko Sasano ◽  
Alex E. Vesely ◽  
Junichiro Hayano ◽  
Hiroshi Sasano ◽  
Ron Somogyi ◽  
...  

Respiratory sinus arrhythmia (RSA) may improve the efficiency of pulmonary gas exchange by matching the pulmonary blood flow to lung volume during each respiratory cycle. If so, an increased demand for pulmonary gas exchange may enhance RSA magnitude. We therefore tested the hypothesis that CO2directly affects RSA in conscious humans even when changes in tidal volume (VT) and breathing frequency ( F B), which indirectly affect RSA, are prevented. In seven healthy subjects, we adjusted end-tidal Pco 2 (Pet CO2 ) to 30, 40, or 50 mmHg in random order at constant VT and F B. The mean amplitude of the high-frequency component of R-R interval variation was used as a quantitative assessment of RSA magnitude. RSA magnitude increased progressively with Pet CO2 ( P < 0.001). Mean R-R interval did not differ at Pet CO2 of 40 and 50 mmHg but was less at 30 mmHg ( P < 0.05). Because VT and F B were constant, these results support our hypothesis that increased CO2directly increases RSA magnitude, probably via a direct effect on medullary mechanisms generating RSA.


2017 ◽  
Vol 46 (2) ◽  
pp. 792-801 ◽  
Author(s):  
W-J Guo ◽  
S-K Yao ◽  
Y-L Zhang ◽  
S-Y Du ◽  
H-F Wang ◽  
...  

Objective This study was performed to investigate impaired vagal activity to meal in patients with functional dyspepsia (FD) with delayed gastric emptying (GE). Methods Eighty-five patients were studied. GE parameters, including those in the overall and proximal stomach, were measured by GE functional tests at the Department of Nuclear Medicine. Autonomic nervous function was tested by spectral analysis of heart rate variability (HRV). The vagal activity and sympathetic activity were analyzed by recording the power in the high-frequency component (HF), low-frequency component (LF), and LF/HF ratio. Results Overall and proximal GE were delayed in 47.2% and 50.9% of the patients, respectively. Spectral analysis of HRV showed that the HF in patients with delayed proximal GE was significantly lower and that the LF/HF ratio was significantly higher than those in patients with normal proximal GE after a meal. Conclusion Delayed proximal GE might be caused by disrupted sympathovagal balance as a result of decreased vagal activity after a meal. Improvement in vagal activity may constitute an effective treatment method for patients with FD.


Sign in / Sign up

Export Citation Format

Share Document