scholarly journals Differential Inductive Sensing System for Truly Contactless Measuring of Liquids’ Electromagnetic Properties in Tubing

Sensors ◽  
2021 ◽  
Vol 21 (16) ◽  
pp. 5535
Author(s):  
Marc Berger ◽  
Anne Zygmanowski ◽  
Stefan Zimmermann

Certain applications require a contactless measurement to eliminate the risk of sensor-induced sample contamination. Examples can be found in chemical process control, biotechnology or medical technology. For instance, in critically ill patients requiring renal replacement therapy, continuous in-line monitoring of blood conductivity as a measure for sodium should be considered. A differential inductive sensing system based on a differential transformer using a specific flow chamber has already proven suitable for this application. However, since the blood in renal replacement therapy is carried in plastic tubing, a direct measurement through the tubing offers a contactless method. Therefore, in this work we present a differential transformer for measuring directly through electrically non-conductive tubing by winding the tube around the ferrite core of the transformer. Here, the dependence of the winding type and the number of turns of the tubing on the sensitivity has been analyzed by using a mathematical model, simulations and experimental validation. A maximum sensitivity of 364.9 mV/mol/L is measured for radial winding around the core. A longitudinal winding turns out to be less effective with 92.8 mV/mol/L. However, the findings prove the ability to use the differential transformer as a truly contactless sensing system.

2016 ◽  
Vol 19 (3) ◽  
pp. 123 ◽  
Author(s):  
Orhan Findik ◽  
Ufuk Aydin ◽  
Ozgur Baris ◽  
Hakan Parlar ◽  
Gokcen Atilboz Alagoz ◽  
...  

<strong>Background:</strong> Acute kidney injury is a common complication of cardiac surgery that increases morbidity and mortality. The aim of the present study is to analyze the association of preoperative serum albumin levels with acute kidney injury and the requirement of renal replacement therapy after isolated coronary artery bypass graft surgery (CABG).<br /><strong>Methods:</strong> We retrospectively reviewed the prospectively collected data of 530 adult patients who underwent isolated CABG surgery with normal renal function. The perioperative clinical data of the patients included demographic data, laboratory data, length of stay, in-hospital complications and mortality. The patient population was divided into two groups: group I patients with preoperative serum albumin levels &lt;3.5 mg/dL; and group II pateints with preoperative serum albumin levels ≥3.5 mg/dL.<br /><strong>Results:</strong> There were 413 patients in group I and 117 patients in group II. Postoperative acute kidney injury (AKI) occured in 33 patients (28.2%) in group I and in 79 patients (19.1%) in group II. Renal replacement therapy was required in 17 patients (3.2%) (8 patients from group I; 9 patients from group II; P = .018). 30-day mortality occurred in 18 patients (3.4%) (10 patients from group I; 8 patients from group II; P = .037). Fourteen of these patients required renal replacement therapy. Logistic regression analysis revealing the presence of lower serum albumin levels preoperatively was shown to be associated with increased incidence of postoperative AKI (OR: 1.661; 95% CI: 1.037-2.661; <br />P = .035). Logistic regression analysis also revealed that DM (OR: 3.325; 95% CI: 2.162-5.114; P = .000) was another independent risk factor for AKI after isolated CABG. <br /><strong>Conclusion:</strong> Low preoperative serum albumin levels result in severe acute kidney injury and increase the rate of renal replacement therapy and mortality after isolated CABG.


Sign in / Sign up

Export Citation Format

Share Document