scholarly journals HPLC-DAD Analysis of Hemp Oil Supplements for Determination of Four Cannabinoids: Cannabidiol, Cannabidiolic Acid, Cannabinol and Delta 9-Tetrahydrocannabinol

Separations ◽  
2021 ◽  
Vol 8 (12) ◽  
pp. 227
Author(s):  
Katarzyna Madej ◽  
Aleksandra Chmiołek ◽  
Kamila Szlachta ◽  
Wojciech Piekoszewski

Growing consumer interest in hemp oilseed supplements requires quality control. Therefore, appropriate, effective and verified analytical methods are needed for the determination of some bioactive cannabinoids in them. The aim of the study is to present an extended (compared to our previous research) validated high performance liquid chromatography with diode array detection (HPLC-DAD) method for the determination of four cannabinoids (cannabidiol, cannabidiolic acid, cannabinol and delta-9-tetrahydrocannabinol) in an oil matrix, which was used to determine these cannabinoids in seven commercial hemp oil supplements. In our method, the isolation of the target compounds was based on liquid extraction with acetonitrile combined with the freezing (at −41 °C) of the oil phase. The results show that in some cases, the determined concentrations of cannabinoids in the tested supplements differ significantly from those declared by the manufacturers. As for the main medicinal cannabinoid (CBD) in hemp oil supplements, in two cases, the measured concentration was significantly lower (1.45 and 1.81%) than the declared (5 and 5%), and in the other supplements, the obtained results confirm the declared amount of CBD within the error range from 3.29 to 9.2%. Therefore, to ensure the safe and beneficial use of these supplements by consumers, it is necessary to monitor their cannabinoid composition.

Sign in / Sign up

Export Citation Format

Share Document