scholarly journals Swine Small Intestine Sealing Performed by Different Vessel Sealing Devices: Ex-Vivo Test

2021 ◽  
Vol 8 (2) ◽  
pp. 34
Author(s):  
Luca Lacitignola ◽  
Annarita Imperante ◽  
Rodrigo Trisciuzzi ◽  
Nicola Zizzo ◽  
Alberto Maria Crovace ◽  
...  

This study aimed to evaluate the sealing quality of swine small intestine using different laparoscopic radiofrequency vessel sealing devices (two 5 mm: RFVS-1 and -2; one 10 mm: RFVS-3) and a harmonic scalpel (HS) compared to golden standard closure technique. The study was divided into two arms. In study arm 1: n = 50 swine intestinal loops (10 per group) were transected with each instrument and the loops in which the devices provided complete sealing, at the gross inspection, were tested for maximum burst pressure (BP) and histological evaluation and compared to an automatic linear stapler. After the BP tests, the devices that achieved significantly lower BP values were excluded from the second arm. The RFVS-1 and -3 provided statistically significant results and were used in study arm 2, to obtain full-thickness biopsies along the antimesenteric border of the loop and were compared with hand-sewn intestinal closure (n = 30; 10 per group). The biopsies were histologically evaluated for thermal injury and diagnostic features, and intestinal loops tested for BP. RFVS-3 achieved comparable results (69.78 ± 4.23 mmHg, interquartile range (IQR) 5.8) to stapler closing technique (71.09 ± 4.22 mmHg, IQR 4.38; p > 0.05), while the RFVS-1 resulted in significantly (p < 0.05) lower BP (45.28 ± 15.23 mmHg, IQR 24.95) but over the physiological range, conversely to RFVS-2 (20.16 ± 7.19 mmHg, IQR 12.02) and HS (not measurable). RFVS-3 resulted not significantly different (p > 0.05) (45.09 ± 8.75 mmHg, IQR 10.48) than Suture (35.71 ± 17.51 mmHg, IQR 23.77); RFVS-1 resulted significantly lower values (23.96 ± 10.63 mmHg, IQR 9.62; p < 0.05). All biopsies were judged diagnostic. Data confirmed that RFVS-1 and -3 devices provided suitable intestinal sealing, with BP pressures over the physiological range. Conversely, the HS and RFVS-2 should not be considered for intestinal sealing. RFVS devices could be employed to obtain small intestine stump closure or full-thickness biopsies. However, further studies should be performed in live animals to assess the role of the healing process.

2017 ◽  
Author(s):  
J Houriet ◽  
YE Arnold ◽  
C Petit ◽  
YN Kalia ◽  
JL Wolfender

2021 ◽  
Vol 7 ◽  
pp. 205951312098853
Author(s):  
Dana M Hutchison ◽  
Amir A Hakimi ◽  
Avin Wijayaweera ◽  
Soohong Seo ◽  
Ellen M Hong ◽  
...  

Introduction: Scar treatments aim to address pathologic collagen deposition; however, they can be expensive or difficult to control. Electrochemical therapy (ECT) offers a simple alternative treatment. The purpose of this study is to examine the acid-base and histological changes in ex vivo human abdominal skin following ECT. Methods: Forty-two ex vivo human panniculus tissue sections collected from six individuals were tumesced with normal saline. ECT was performed by inserting two platinum needle electrodes connected to a DC power supply into each specimen. Voltage was varied (3–6 V) and applied for 5 minutes. Each specimen was sectioned across both electrode insertion sites and immediately stained with pH sensitive dye. The width of dye color change for each dosimetry pair was calculated. Hematoxylin and eosin staining was used to evaluate samples. Results and Discussion: ECT caused a spatially localised and dose-dependent increased area of acidic and basic pH around the anode and cathode, respectively. A significantly greater mean width of pH change was generated at the cathode compared to the anode in all treatment groups. Histological evaluation displayed broad condensation and hyalinisation of dermal collagen. Conclusion: ECT triggered dermal pH alterations and changed the underlying structural framework of the specimen. This technology may serve as a low-cost, minimally invasive local soft-tissue remodeling technique with potential application in scar management. Level of Evidence: 5 Lay Summary Electrochemical therapy is a novel treatment that causes spatially selective dermal injury in areas of interest. This study measures the effects of electrochemical therapy when applied to abdominal skin. Electrochemical therapy appears to have beneficial effects by causing a highly localised reduction in collagen content or local softening of tissue, which is consistent with other studies on scar therapies, including chemexfoliation, radiofrequency technologies, and lasers. However, electrochemical therapy can be performed at a fraction of the costs of these aforementioned modalities.


Molecules ◽  
2021 ◽  
Vol 26 (9) ◽  
pp. 2554
Author(s):  
Marek Konop ◽  
Anna K. Laskowska ◽  
Mateusz Rybka ◽  
Ewa Kłodzińska ◽  
Dorota Sulejczak ◽  
...  

Impaired wound healing is a major medical challenge, especially in diabetics. Over the centuries, the main goal of tissue engineering and regenerative medicine has been to invent biomaterials that accelerate the wound healing process. In this context, keratin-derived biomaterial is a promising candidate due to its biocompatibility and biodegradability. In this study, we evaluated an insoluble fraction of keratin containing casomorphin as a wound dressing in a full-thickness surgical skin wound model in mice (n = 20) with iatrogenically induced diabetes. Casomorphin, an opioid peptide with analgesic properties, was incorporated into keratin and shown to be slowly released from the dressing. An in vitro study showed that keratin-casomorphin dressing is biocompatible, non-toxic, and supports cell growth. In vivo experiments demonstrated that keratin-casomorphin dressing significantly (p < 0.05) accelerates the whole process of skin wound healing to the its final stage. Wounds covered with keratin-casomorphin dressing underwent reepithelization faster, ending up with a thicker epidermis than control wounds, as confirmed by histopathological and immunohistochemical examinations. This investigated dressing stimulated macrophages infiltration, which favors tissue remodeling and regeneration, unlike in the control wounds in which neutrophils predominated. Additionally, in dressed wounds, the number of microhemorrhages was significantly decreased (p < 0.05) as compared with control wounds. The dressing was naturally incorporated into regenerating tissue during the wound healing process. Applied keratin dressing favored reconstruction of more regular skin structure and assured better cosmetic outcome in terms of scar formation and appearance. Our results have shown that insoluble keratin wound dressing containing casomorphin supports skin wound healing in diabetic mice.


Author(s):  
Emilio Bertani ◽  
Francesco Collamati ◽  
Marzia Colandrea ◽  
Riccardo Faccini ◽  
Nicola Fazio ◽  
...  

2017 ◽  
Vol 11 (4) ◽  
Author(s):  
Mark J. Hedgeland ◽  
Alexander Martin Clark ◽  
Mario J. Ciani ◽  
Arthur J. Michalek ◽  
Laurel Kuxhaus

An adjustable-length intramedullary (IM) nail may reduce both complications secondary to fracture fixation and manufacturing costs. We hypothesized that our novel nail would have suitable mechanical performance. To test this hypothesis, we manufactured three prototypes and evaluated them in quasi-static axial compression and torsion and quasi-static four-point bending. Prototypes were dynamically evaluated in both cyclic axial loading and four-point bending and torsion-to-failure. The prototypes exceeded expectations; they were comparable in both quasi-static axial stiffness (1.41 ± 0.37 N/m in cervine tibiae and 2.30 ± 0.63 in cadaver tibiae) and torsional stiffness (1.05 ± 0.26 N·m/deg in cervine tibiae) to currently used nails. The quasi-static four-point bending stiffness was 80.11 ± 09.360, greater than reported for currently used nails. A length-variance analysis indicates that moderate changes in length do not unacceptably alter bone-implant axial stiffness. After 103,000 cycles of axial loading, the prototype failed at the locking screws, comparable to locking screw failures seen clinically. The prototypes survived 1,000,000 cycles of four-point bend cyclic loading, as indicated by a consistent phase angle throughout cyclic loading. The torsion-to-failure test suggests that the prototype has adequate resistance to applied torques that might occur during the healing process. Together, these results suggest that our novel IM nail performs sufficiently well to merit further development. If brought to market, this adjustable-length IM nail could reduce both patient complications and healthcare costs.


2001 ◽  
Vol 281 (3) ◽  
pp. G798-G808 ◽  
Author(s):  
H. Takahara ◽  
M. Fujimura ◽  
S. Taniguchi ◽  
N. Hayashi ◽  
T. Nakamura ◽  
...  

Few previous studies have discussed the changes in serotonin receptor activity in the small intestine of diabetic animals. Therefore, we examined serotonin content in duodenal tissue and dose-dependent effects of serotonin agonists and antagonists on the motor activity of ex vivo vascularly perfused duodenum of streptozotocin (STZ)-diabetic rats. Serotonin content was significantly increased in enterochromaffin cells but not altered in serotonin-containing neurons in STZ-diabetic rats. Motor activity assessed by frequency, amplitude, and percent motility index per 10 min of pressure waves was reduced in the duodenum of diabetic rats, and this reduction was reversed by insulin treatment. Serotonin dose dependently increased the motor activity in control rat duodenum but only a higher concentration of serotonin increased the motor activity in diabetic rats. The 5-hydroxytryptamine (5-HT) receptor subtype 4 (5-HT4) antagonist SB-204070 dose dependently reduced motor activity in both control and diabetic rats, whereas the 5-HT3receptor antagonist azasetron, even at a higher concentration, failed to affect motor activity in diabetic rat duodenum but dose dependently reduced motor activity in control rat duodenum. These results suggest that 5-HT3receptor activity was impaired but 5-HT4receptor activity was intact in STZ-diabetic rat duodenum. Such an impairment of 5-HT3receptor activity may induce the motility disturbance in the small intestine of diabetes mellitus.


Author(s):  
Vladislav A Dolgachev ◽  
Susan Ciotti ◽  
Emma Liechty ◽  
Benjamin Levi ◽  
Stewart C Wang ◽  
...  

Abstract Objective Burn wound progression is an inflammation driven process where an initial partial-thickness thermal burn wound can evolve over time to a full-thickness injury. We have developed an oil-in-water nanoemulsion formulation (NB-201) containing benzalkonium chloride for use in burn wounds that is antimicrobial and potentially inhibits burn wound progression. We used a porcine burn injury model to evaluate the effect of topical nanoemulsion treatment on burn wound conversion and healing. Methods Anesthetized swine received thermal burn wounds using a 25cm 2 surface area copper bar heated to 80 oC. Three different concentrations of NB-201 (10%, 20%, or 40% nanoemulsion), silver sulfadiazine cream or saline were applied to burned skin immediately after injury and on days 1, 2, 4, 7, 10, 14, and 18 post-injury. Digital images and skin biopsies were taken at each dressing change. Skin biopsy samples were stained for histological evaluation and graded. Skin tissue samples were also assayed for mediators of inflammation. Results Dermal treatment with NB-201 diminished thermal burn wound conversion to a full-thickness injury as determined by both histological and visual evaluation. Comparison of epithelial restoration on day 21 showed that 77.8% of the nanoemulsion treated wounds had an epidermal injury score of 0 compared to 16.7% of the silver sulfadiazine treated burns (p=0.01). Silver sulfadiazine cream and saline treated wounds (controls) converted to full-thickness burns by day 4. Histological evaluation revealed reduced inflammation and evidence of skin injury in NB-201 treated sites compared to control wounds. The nanoemulsion treated wounds often healed with complete regrowth of epithelium and no loss of hair follicles (NB-201: 4.8±2.1, saline: 0±0, silver sulfadiazine: 0±0 hair follicles per 4mm biopsy section, p&lt;0.05). Production of inflammatory mediators and sequestration of neutrophils were also inhibited by NB-201. Conclusions Topically applied NB-201 prevented the progression of a partial-thickness burn wound to full-thickness injury and was associated with a concurrent decrease in dermal inflammation.