scholarly journals AN OPTIMIZATION OF A DIGITAL CONTROLLER FOR A STOCHASTIC CONTROL SYSTEM

Author(s):  
Igor Golinko ◽  
Volodymyr Drevetskiy

The article deals with the synthesis of an optimal digital controller for a stochastic plant. In order to optimize the control system, an integral quality criterion together with minimization of the controlled parameter variance that is offered here, besides the control actions the control objects are taken into account. Using the methods of optimization theory for a single-loop control system, the structure and parameters of the digital regulator are determined. The structure of the digital controller is analysed from the parameters of the quality criterion and the mathematical description of the control object. An example of the synthesis of a digital controller for an automatic control system for the air temperature at the output of the CV-P°2L°N-63B/F-N ceiling conditioner, which showed the efficiency of the digital controller when compensating for random disturbances, is given here. The obtained results are recommended to be used by the specialists on automation for the control system design as well as optimization of the existing ones.

2012 ◽  
Vol 235 ◽  
pp. 186-191
Author(s):  
Gui Ying Lu ◽  
Yuan Sheng Wang ◽  
Bo Li ◽  
Juan Yu

The structure and its function about a dual-axis rate turntable has been elaborated, its principle block diagram of control system is given. And its electromechanical system’s transfer function of the dual-axis rate table has been calculated and simplified reasonably based on experiments and practical situation, then a double loop control system constituted with a speed loop and a stabilization loop is got. Its’ correction link of the stabilization loop is calculated, which has a 2-order open loop transfer function. In order to achieve a suitable stability margin, the corresponding digital controller is designed, and its’ pulse transfer function response and the three-step iterative simulation results to a same sinusoidal excitation are got and compared, the same results verified the correctness of the design to the correction link.


2015 ◽  
Vol 727-728 ◽  
pp. 712-716
Author(s):  
Zhi Wei Guo ◽  
Cong Quan Hu

The article describes three usual manners and introduces about one Siemens S7-200PLC’s closed loop control system how to realize the PID , the principle of the PID digital controller, how to use the PID digital controller, an example about how to program with it, and how to convert the input-output variable.


2011 ◽  
Vol 219-220 ◽  
pp. 3-7
Author(s):  
Ning Zhang ◽  
Rong Hua Liu

An expert control system based on transient response patterns and expert system techniques is proposed in this paper. Depending on the features of the closed-loop control system determines the control decision and adjusts the parameters of the controller. The proposed method requires minimal proper information about the controlled plant and, with the linear re-excitation learning method, the system is kept satisfying the performance criterion.


2017 ◽  
Vol 3 (2) ◽  
pp. 363-366
Author(s):  
Tobias Steege ◽  
Mathias Busek ◽  
Stefan Grünzner ◽  
Andrés Fabían Lasagni ◽  
Frank Sonntag

AbstractTo improve cell vitality, sufficient oxygen supply is an important factor. A deficiency in oxygen is called Hypoxia and can influence for example tumor growth or inflammatory processes. Hypoxia assays are usually performed with the help of animal or static human cell culture models. The main disadvantage of these methods is that the results are hardly transferable to the human physiology. Microfluidic 3D cell cultivation systems for perfused hypoxia assays may overcome this issue since they can mimic the in-vivo situation in the human body much better. Such a Hypoxia-on-a-Chip system was recently developed. The chip system consists of several individually laser-structured layers which are bonded using a hot press or chemical treatment. Oxygen sensing spots are integrated into the system which can be monitored continuously with an optical sensor by means of fluorescence lifetime detection.Hereby presented is the developed hard- and software requiered to control the oxygen content within this microfluidic system. This system forms a closed-loop control system which is parameterized and evaluated.


2011 ◽  
Vol 418-420 ◽  
pp. 1865-1868
Author(s):  
Ming Jin Yang ◽  
Xi Wen Li ◽  
Zhi Gang Wang ◽  
Tie Lin Shi

The performance of speed regulating is very important to the mixing process with safe, efficient operation and high quality of production. Strategies and practices of responses and optimization of a PID-based speed regulating system of a planetary mixer were presented in this paper. Research results show that: by means of the signal constraint function presented by Simulink Response Optimization, optimization PID parameters of the 2-DOF-PID controller can be obtained, and the response of close-loop control system has quite good performance of overshoot, response time, and stability compared with an open-loop control system.


Author(s):  
Bahram Yaghooti ◽  
Ali Siahi Shadbad ◽  
Kaveh Safavi ◽  
Hassan Salarieh

In this article, an adaptive nonlinear controller is designed to synchronize two uncertain fractional-order chaotic systems using fractional-order sliding mode control. The controller structure and adaptation laws are chosen such that asymptotic stability of the closed-loop control system is guaranteed. The adaptation laws are being calculated from a proper sliding surface using the Lyapunov stability theory. This method guarantees the closed-loop control system robustness against the system uncertainties and external disturbances. Eventually, the presented method is used to synchronize two fractional-order gyro and Duffing systems, and the numerical simulation results demonstrate the effectiveness of this method.


2012 ◽  
Vol 229-231 ◽  
pp. 2201-2204
Author(s):  
Cun Hai Pan ◽  
Hui Li ◽  
Su Mei Du ◽  
Wei Gao

A twin-rotary motion control system was built based on a cam technology and Siemens S7-300T PLC in this paper. The system can position accurately in a three-dimension space using a twin-servo closed loop control system and can real-time monitor various parameters of positioning system by HMI (Human Machine Interface). It also can automatically collect various parameter information and judge the type of fault.At the same time, the degree of automation has been raised and the cost of production was reduced.


Sign in / Sign up

Export Citation Format

Share Document