scholarly journals Fault Clearance in Nine-Bus system using Custom Power Devices

The power transfer capability of a system determines the power quality and the reliability of the power system. The transmission side of the power system is of different configuration. This paper involves the modeling of a three-phase multi-machine system with nine bus configurations. The system is subjected to different fault conditions. The system is modeled with the help of MATLAB- Simulink. The power quality of the system is analyzed. The system active and the reactive power can be compensated by the FACTS devices. The FACTS devices are power compensating devices that play a vital role in increasing the power quality of the system. The three-phase multi-machine system is integrated with the FACTS devices like STATCOM and UPFC and different parameters where analyzed

Author(s):  
Liu Yang ◽  
Qinyue Tan ◽  
Di Xiong ◽  
Zhengguang Liu

The overrun of transient power quality index caused by the large-capacity electric arc furnace (EAF) has become a prominent problem affecting the safe and stable operation of the power system. (1) In this paper, the relationship between arc furnace volt-age and current is derived based on the different stages of arc combustion, and the random variation of chaotic phenomenon of the arc voltage are simulated. Established an EAF model suitable for the study of transient power quality problems. (2) Take 50t AC EAF as an example to analyze the reactive power impact and the influence on the point of common coupling (PCC) voltage caused by the three-phase short circuit of the electrode. The results show that the experimental results are consistent with the theoretical analysis, verifying the correctness and effectiveness of the model. (3) When the three-phase short-circuit occurs, the reactive power impact is nearly 6 times that of normal operation, the short-circuit current is 2.66 times that of normal operation, and the effective value of the PCC voltage has dropped by 40.37%, which provides a theoretical basis for real-time compensation of impulsive reactive power and improvement of the transient power quality of the EAF.


Circuit World ◽  
2020 ◽  
Vol 47 (1) ◽  
pp. 11-21
Author(s):  
Ananthan Nagarajan ◽  
Sivachandran P. ◽  
Suganyadevi M.V. ◽  
Muthukumar P.

Purpose The purpose of this study is to help the researchers, public, industries and government to realize the tremendous trends to improve the power quality of both sources and load side. Design/methodology/approach The work carried out in the Facts device and power quality issues. Findings Maintaining the quality of electric power is always a challenging task. The effect of power electronics devices leads to improper power quality. The use of FACTS devices is preferably the best approach to treat power-quality-related problems. Usually, all FACTS devices are constructed to operate on the side of either the source side or the load. Originality/value This paper explores a broad comprehensive study of various types of power quality problems and classification of FACTS devices with its recent developments. Furthermore unified power quality conditioner (UPQC) is particularly reviewed to highlight the advantages over other compensating devices. An exhaustive study of literature has been carried out and most significant concepts are presented


2020 ◽  
Vol 8 (5) ◽  
pp. 1962-1969

The Unified Power Quality Controller (UPQC) is the Custom Power device designed for improving the power quality of the electrical network. In this paper, we proposed UPQC design for an isolated power system network to attend both voltage and current distortion by using Unit Vector template algorithm and Instantaneous Reactive Power theory. Also UPQC is designed for the hybrid generation with Hysteresis control algorithm. The power quality improvement of the power system network is the main aim . The performance analysis is done by comparing its Total Harmonic Distortion (THD). Based on its THD the quality of the power at the “Point of common coupling (PCC)”with and without compensator is quantified in this paper. Keywords : About four key words or phrases in alphabetical order, separated by commas.


Energies ◽  
2019 ◽  
Vol 12 (20) ◽  
pp. 3971 ◽  
Author(s):  
Fermín Barrero-González ◽  
María Isabel Milanés-Montero ◽  
Eva González-Romera ◽  
Enrique Romero-Cadaval ◽  
Carlos Roncero-Clemente

Based on the assumption that vehicles served by petrol stations will be replaced by Electric Vehicles (EV) in the future, EV public charging station facilities, with off-board fast chargers, will be progressively built. The power demand of these installations is expected to cause great impact on the grid, not only in terms of peak power demanded but also in terms of power quality, because most battery chargers behave as non-linear loads. This paper presents the proposal of a novel comprehensive global control strategy for the power electronic converters associated with bidirectional three-phase EV off-board fast chargers. The Charging Station facility Energy Management System (CS-EMS) sends to each individual fast charger the active and reactive power setpoints. Besides, in case the charger has available capacity, it is assigned to compensate a fraction of the harmonic current demanded by other loads at the charging facility. The proposed approach works well under distorted and unbalanced grid voltages. Its implementation results in improvement in the power quality of each fast charger, which contributes to improvement in the power quality at the charging station facility level, which can even provide ancillary services to the distribution network. Simulation tests are conducted, using a 100 kW power electronic converter model, under different load and grid conditions, to validate the effectiveness and the applicability of the proposed control strategy.


Author(s):  
B. Santhosh Kumar ◽  
K.B. Madhu Sahu ◽  
K.B. Saikiran ◽  
CH. Krishna Rao

This paper investigates the problems associated with distribution system in terms of delivery of clean power and their solutions. Power quality has become a major issue in the present power system network. The network has mostly inductive nature.  This draws more reactive power.  This causes harmonics and voltage unbalance problems. So maintain the proper operation of interconnected power system, we are using one of the facts devices such as fuzzy controlled D-statcom. It provides suitable compensation and there by maintain proper power factor and also reduces harmonic contents.  The simulation is taken out by MATLAB/SIMULINK and the result shows the effectiveness of GA (Genetic algorithm) simulation. Optimized Fuzzy controlled D-STATCOM for improvement of power quality.


2020 ◽  
Vol 22 (1-2) ◽  
pp. 137-144
Author(s):  
Hidajet Salkić ◽  
Amir Softić ◽  
Amer Salkić

The electric power system, as an integrated system for transmission, distribution and consumption of electricity, is one of the most complex technical and economic systems today. Customers affect on the voltage quality of power network, but the network also has an impact on customers. All disturbances in the network can disrupt operation of the network and affect on operation of the customers, as well as reduce the level of efficiency and operation life or even seriously damage network. Number of customers is increasing every day, as well as proportion of customers who generate disturbances in the network and, at the same time, are sensitive to them. These circumstances impose the need for frequent monitoring of the network, so the analysis of power quality is not unjustified cost but extremely important and profitable investment. The quality of electricity, as part of the overall quality supply of electricity customers in deregulated conditions of liberal electricity market becomes significant regulatory parameter for network operators and a significant contracting parameter on the electricity market. Network operators are obliged to establish a system of individual measurements and a system of permanent monitoring of power quality parameters to determine the state and improve the parameters to the standardized level. Technical parameters are determined by the recommendations made at the international level and may, but do not need, be legally binding. Maintaining a certain level of voltage quality at some point of the network is the responsibility of electricity distributor. This task distributor executes by limiting of negative effects of producer/customer to the network. Therefore, each electricity producer/customer is obliged to reduce own negative feedback effects (injection of higher harmonics, taking of reactive power, emissions of flickers and loads unbalances) to a prescribed, prearranged, limited values. There are many norms that describe the quality of electricity, but in Europe the best known is EN50160 (issued by CENLEC). This paper presents the approach to measuring the voltage quality at the point of electricity delivery from distributed source into distribution network from the aspect of limiting the negative feedback of distributed source on the voltage quality.


2015 ◽  
Vol 16 (4) ◽  
pp. 357-384 ◽  
Author(s):  
Suresh Mikkili ◽  
Anup Kumar Panda

Abstract Electrical power quality has been an important and growing problem because of the proliferation of nonlinear loads such as power electronic converters in typical power distribution systems in recent years. Particularly, voltage harmonics and power distribution equipment problems result from current harmonics produced by nonlinear loads. The Electronic equipment like, computers, battery chargers, electronic ballasts, variable frequency drives, and switch mode power supplies, generate perilous harmonics and cause enormous economic loss every year. Problems caused by power quality have great adverse economic impact on the utilities and customers. Due to that both power suppliers and power consumers are concerned about the power quality problems and compensation techniques. Power quality has become more and more serious with each passing day. As a result active power filter gains much more attention due to excellent harmonic and reactive power compensation in two-wire (single phase), three-wire (three-phase without neutral), and four-wire (three-phase with neutral) ac power networks with nonlinear loads. However, this is still a technology under development, and many new contributions and new control topologies have been reported in the last few years. It is aimed at providing a broad perspective on the status of APF technology to the researchers and application engineers dealing with power quality issues.


2019 ◽  
Vol 4 (9) ◽  
pp. 1-8
Author(s):  
Montaser Abd El Sattar ◽  
Adel A. Elbaset ◽  
Ali H. KasemAlaboudy ◽  
Wessam Arafa Hafez

Wind energy system is lately receiving a lot of attention, because they are cost inexpensive, environmental safe and clean renewable energy source, as compared with nuclear and fossil fuel power generation. The operational characteristics of wind electric turbines has considerable dissatisfaction and stress on the quality of electric power system. Harmonics, variations of voltage and reactive power are most of power quality issues for grid connected with wind turbine. This paper introduces a design and simulation of unified power quality conditioner using a fuzzy controller to improve the power quality for Egyptian power grid connected to Zafarana Egypt wind system. The proposed performance of the unified power quality conditioner system is verified by simulating the model using MATLAB/SIMULINK environment. The simulation results showed that the proposed unified power quality conditioner provide efficient cancellation of both load current  harmonics  and supply voltage sag in addition to compensation of reactive power, and thus making the electrical grid connected wind energy system more efficient by improving the quality of power.


Sign in / Sign up

Export Citation Format