AN OBSERVATIONAL STUDY OF HEARING THRESHOLDS IN PROFESSIONAL DRIVERS

2021 ◽  
pp. 49-51
Author(s):  
R. Shanthimalar ◽  
R. Bhuvaneswari ◽  
V. Sumathi

Introduction: Noise has become a very important stress factor in the environment. Drivers are the most commonly affected persons due to trafc noise. The majority of drivers remain unaware about noise induced hearing loss as this is an insidious process, leading to temporary or permanent hearing impairment, but preventable. Pure Tone audiometric test is used to determine the degree of hearing loss in noise exposed individuals. Aim & Objective: To nd the hearing threshold levels for high and mid frequency sounds for both ears in Professional drivers. To evaluate the preponderance of hearing loss between right and left ear using hearing thresholds. Materials & Methods: This study was conducted in 100 Professional male drivers aged between 30-40 years who are working in Tamil Nadu State Transport Corporation, Madurai. Pure tone audiometry was used to measure the high and mid frequency hearing threshold levels in both ears. Results: The mean (SD) hearing threshold for high and mid frequency sounds was signicantly higher in left ear comparative to right ear with P value < 0.05. The statistically signicant difference in hearing loss was observed between both ears. Conclusion : Our study showed statistically signicant higher hearing threshold for high and mid frequency sounds in left ear compared to right ear, that concludes left ear is more prone for hearing loss than the right ear

2020 ◽  
Vol 14 (2) ◽  
pp. 106-114
Author(s):  
Abdullahi Musa Kirfi ◽  
◽  
Mohammed Bello Fufore ◽  
Garba Mohammed Mainasara ◽  
Abdulrazak Ajiya ◽  
...  

Background: Prisoners, due to confinement are isolated from contact with the society and access to many of the facilities, including medical care. This study aimed to evaluate the hearing threshold of inmates of Kaduna convict prison. Method: It was a cross-sectional study of prison inmates at the Kaduna convict prison between April 2017 and February 2019. Ethical approvals were obtained from relevant bodies and all consented inmates aged 18 – 55years in the Kaduna convict prison were enrolled. Equal number of control matched for age and gender were enrolled from the communities in Kaduna North Local Government Area. Data were collated using a structured questionnaire. A diagnostic Pure Tone Audiometry was performed to assess their hearing threshold. Statistical Package for Social Sciences (SPSS) version 20.0 was used for analysis. Results: Four hundred and thirty inmates and equal number of control group were enrolled. The mean age for the inmates and controls were 30.2±7.5 and 30.4±8.02 years respectively. There were 383 males and 47 females in both groups. Among the 860 ears of the inmates, 238(27.7%) ears had hearing loss while in the control group, 95/ (11.1%) ears had impaired hearing. Conductive hearing loss was the commonest among the inmates 111(46.6%) while sensorineural was commoner among the controls 57(60.0%). The mean pure tone average among the inmates was 25.6±11.3dBHL and 26.1±11.2dBHL on the right and left ears respectively while in the control group, it was 18.4±7.8dBHL on the right and 17.9±7.9dBHL on the left. Conclusion: This study revealed that hearing loss was more prevalent among prison inmates than the general population. In majority of the inmates, the hearing loss was mild, conductive and mostly affecting all the frequencies.


2010 ◽  
Vol 67 (9) ◽  
pp. 761-765 ◽  
Author(s):  
Zoran Komazec ◽  
Slobodanka Lemajic-Komazec ◽  
Rajko Jovic ◽  
Congor Nadj ◽  
Ljiljana Jovancevic ◽  
...  

Background/Aim. A more recent method, the auditory steadystate response (ASSR), has become more and more important test method due to difference that was found in previous investigations between hearing thresholds determined by the ASSR and the pure-tone audiometry (PTA). The aim of this study was to evaluate the reliability of the ASSR in determining the frequency specific hearing thresholds by establishing a correlation between the thresholds determined by PTA, as well as to evaluate the reliability of ASSR in determining the hearing threshold with respect to the level of hearing loss and the configuration of the PTA findings. Methods. The prospective study included 46 subjects (92 ears) which were assigned to groups based on their level of hearing loss and audiometric configuration. All the subjects underwent determination of hearing thresholds by PTA and ASSR without insight into their previously obtained PTA results. Results. The overall sample differences between the ASSR and PTA thresholds were 4.1, 2.5, 4.4, and 4.2 dB at 0.5, 1, 2, and 4 kHz, respectively. A high level of correlation was achieved in groups with different configurations of PTA findings. The correlation coefficients between the hearing thresholds determined by ASSR and PTA were significant in subjects with all levels of hearing loss. The differences between hearing thresholds determined by ASSR and PTA were less than 10 dB in 85% of subjects (ranging from 4 dB for moderately severe hearing loss to 7.2 dB for normal hearing). Conclusion. The ASSR is an excellent complementary method for the determination of hearing thresholds at the 4 carrier frequencies, as well as determination of the level of hearing loss and the audiometric configuration.


2021 ◽  
Author(s):  
Abubakar O Aliyu ◽  
Waheed A Adedeji ◽  
Adekunle Daniel ◽  
Tajudeen Yusuf ◽  
Paul A Onakoya ◽  
...  

Abstract Introduction: Navy personnel are exposed to several risk factors that increase hearing thresholds and impair hearing. The aim of the study was to determine the prevalence of hearing impairment among Nigerian Navy personnel. Materials and Method: This was a cross sectional study of Nigerian Navy personnel working in various ships. Structured, self-administered questionnaire was used to obtain information on hearing. All the subjects had ear examination and pure tone audiometry of both ears. Results: The prevalence of hearing impairment was 22(14.7%) in the right and 17(11.3%) in the left ears. The Pure Tone Average for the right and left ear were 19.0±8.6dB and 17.4±6.7dB respectively. There was a statistically significant association between noisy work place and total hearing loss (p<.01), pure tone average in the left ear (p<.05) and frequencies of 3000 Hz (p<.05), 2000 Hz (p<.001) and 1000Hz (p<.05) in the left ear. The association between past history of ear infections and pure tone average in the left ear (p<.05) and the frequency 2000 Hz (p<.005) in the left ear were significant. The length of service years, occupational group, age, sex report of change in hearing, non-use of hearing protection and presence of tinnitus did not show significant association with pure tone averages nor on the frequencies tested. Conclusion: The significant unilateral hearing impairment on the right ear suggests the need for more research on hearing impairment in the Nigerian Navy as well as development of a comprehensive hearing conservation programme.


1995 ◽  
Vol 109 (4) ◽  
pp. 291-295 ◽  
Author(s):  
H. J. Cox ◽  
G. R. Ford

AbstractThe air conduction thresholds in the right and left ears, and the interaural asymmetry of thresholds at 0.5, 1, 2, 3, 4 and 6 kHz were measured in a group of 225 soldiers exposed to a variety of weapon noise who were referred for assessment because of a deterioration in hearing on routine testing. At 0.5 and I kHz the threshold levels rarely exceeded 25 dB and the interaural asymmetry was 10 dB or less in 90 per cent of cases. The degree of hearing loss and interaural asymmetry increased as the frequency increased, with the average loss being significantly greater in the left ear at 2, 3, 4 and 6 kHz.Recommendations are made for the selection of cases of asymmetrical hearing loss exposed to weapon noise which require further investigation to exclude a retrocochlear cause or to define spurious hearing threshold levels.


2013 ◽  
Author(s):  
Βασίλειος Ψαλτάκος

Although several reports exist concerning the occurrence of hearing loss in patients withdisorders of thyroid function, there are still several unsettled issues, such as theincidence and the severity of hearing impairment, the anatomic site of the auditorypathway involved, and the possible pathogenetic mechanisms. Both congenitalhypothyroidism and environmentally based iodine deficiency are established causes ofhearing loss in humans and rodents. Congenital thyroid deficiency in humans can resultin a profound, hearing deficit, which may be prevented by early hormonal replacementtreatment in infants with hypothyroidism. However, the effect of acute or chronichypothyroidism in adults has not been adequately studied, and most information hasbeen obtained from animal experiments, whereas research in humans has been basicallybased on behavioral audiometry. The use of otoacoustic emissions may provide moreinsight into the hearing function of these patients than pure-tone audiometry, since it isconsidered as a sensitive test of the cochlear status. The aim of this study was toevaluate the hearing in a group of patients with acute hypothyroidism, using bothconventional audiometry and transiently evoked otoacoustic emissions (TEOAEs). Material and methods:A group of 52 patients with thyroid carcinoma who underwent total thyroidectomy wasstudied prospectively, All patients were examined before surgery and 6-8 weekspostoperatively. During this period there was no replacement with levothyroxine and themagnitude of thyroxin depletion was monitored by serum thyroid-stimulating hormone levels. On preoperative encounter with each patient, a detailed questionnaire of historyof hearing loss, tinnitus, vertigo, previous ear infections, noise exposure, medications,and recent upper respiratory tract infection was completed. Patients were excluded ifthey were older than 50 years, in order to avoid the phenomenon of presbycusis, or ifthey had a history of cochleovestibular, vascular or neurologic disease, or any other riskfactor for hearing impairment. Pure-tone audiometry, tympanometry and transientlyevoked otoacoustic emissions were performed. A group of healthy volunteers of similarage and sex were used for comparison.Results:(1) Tympanograms were normal, either on initial testing (75%) or on repeat testing(25%).(2) Audiometry showed elevation of all postoperative hearing thresholds, whereas thethresholds varied significantly across frequency.(3) TEOAE testing showed response signal to noise ratios lower in the postoperativesession (hypothyroid state) than in the preoperative session on all measured frequencies.(4) Emission levels varied significantly across frequency, with maximum responseobserved at 2 kHz.(5) Comparison of significant pure-tone and otoacoustic emission shifts for individualears showed more ears affected in otoacoustic emission testing, indicating subclinicalcochlear involvement.(6) Comparison of hearing thresholds and otoacoustic emission levels between patientsand controls showed significant differences on postoperative testing. Conclusions:Acute hypothyroidism in adults causes elevation of hearing thresholds and reducedotoacoustic emissions. The effect on otoacoustic emissions is greater, indicatingsubclinical damage of the cochlear function.


e-CliniC ◽  
2015 ◽  
Vol 3 (1) ◽  
Author(s):  
Febrina R. Wuwung ◽  
Ora I. Palandeng ◽  
Olivia C. P. Pelealu

Abstract: Diabetes mellitus is a group of chronic metabolic disease which can affect nearly every organ system in the body. Complications of this disease are diverse and include retinopathy, nepropathy and neuropathy. It has a high prevalence and continued to increase. The relationship between diabetes mellitus and hearing loss have been studied. This study aimed to obtain the average of hearing threshold in patients with diabetes mellitus. This was a descriptive observational study with a cross sectional design. Total 38 diabetes mellitus patients were included in the study. Hearing threshold obtained based on air conduction pure tone audiometry average at 500, 1000, 2000, and 4000 Hz. The results showed that subjects were 65.8% females and 32.4% males. There were 9 subjects (23.6%) with normal hearing, 24 subjects (63.2%) with bilateral hearing loss, and 5 subjects (13.2%) with unilateral hearing loss. Of the 29 subjects with hearing loss, the levels were mild and moderate. None of the subjects had moderately severe, severe, or profound. Conclusion: The majority of subjects in this study had hearing loss.Keywords: diabetes mellitus, hearing threshold, pure tone audiometryAbstrak: Diabetes melitus merupakan suatu kelompok penyakit metabolik kronik yang dapat mempengaruhi hampir setiap sistem organ dalam tubuh. Komplikasi penyakit ini beragam, termasuk retinopati, nefropati dan neuropati. Prevalensinya cukup tinggi dan diperkirakan akan terus meningkat. Terdapat beberapa penelitian yang menghubungkan diabetes melitus dan gangguan pendengaran. Penelitian ini bertujuan untuk mengetahui ambang pendengaran rata – rata pada penderita diabetes melitus. Penelitian ini merupakan penelitian deskriptif observasional dengan desain penelitian potong lintang. Sampel total ialah 38 pasien diabetes melitus. Ambang pendengaran rata – rata diperoleh berdasarkan hantaran udara audiometri nada murni rata-rata pada frekuensi 500, 1000, 2000, dan 4000 Hz. Hasil penelitian memperlihatkan bahwa subjek penelitian 65,8% perempuan dan 34,2% laki – laki. Terdapat 9 orang (23,6%) yang mempunyai pendengaran normal, 24 orang (63,2 %) mengalami gangguan pendengaran bilateral dan 5 orang (13,2%) dengan gangguan pendengaran unilateral. Dari 29 subjek penelitian dengan gangguan pendengaran mengalami gangguan pendengaran kategori ringan dan sedang. Tidak ditemukan subjek penelitian dengan gangguan pendengaran kategori sedang berat, berat atau sangat berat. Simpulan: Mayoritas subjek penelitian mengalami gangguan pendengar.Kata kunci: ambang pendengaran, audiometri nada murni, diabetes melitus


2021 ◽  
Vol 3 ◽  
Author(s):  
Marco Cox ◽  
Bert de Vries

Pure-tone audiometry—the process of estimating a person's hearing threshold from “audible” and “inaudible” responses to tones of varying frequency and intensity—is the basis for diagnosing and quantifying hearing loss. By taking a probabilistic modeling approach, both optimal tone selection (in terms of expected information gain) and hearing threshold estimation can be derived through Bayesian inference methods. The performance of probabilistic model-based audiometry methods is directly linked to the quality of the underlying model. In recent years, Gaussian process (GP) models have been shown to provide good results in this context. We present methods to improve the efficiency of GP-based audiometry procedures by improving the underlying model. Instead of a single GP, we propose to use a GP mixture model that can be conditioned on side-information about the subject. The underlying idea is that one can typically distinguish between different types of hearing thresholds, enabling a mixture model to better capture the statistical properties of hearing thresholds among a population. Instead of modeling all hearing thresholds by a single GP, a mixture model allows specific types of hearing thresholds to be modeled by independent GP models. Moreover, the mixing coefficients can be conditioned on side-information such as age and gender, capturing the correlations between age, gender, and hearing threshold. We show how a GP mixture model can be optimized for a specific target population by learning the parameters from a data set containing annotated audiograms. We also derive an optimal tone selection method based on greedy information gain maximization, as well as hearing threshold estimation through Bayesian inference. The proposed models are fitted to a data set containing roughly 176 thousand annotated audiograms collected in the Nordic countries. We compare the predictive accuracies of optimized mixture models of varying sizes with that of an optimized single-GP model. The usefulness of the optimized models is tested in audiometry simulations. Simulation results indicate that an optimized GP mixture model can significantly outperform an optimized single-GP model in terms of predictive accuracy, and leads to significant increases the efficiency of the resulting Bayesian audiometry procedure.


2015 ◽  
Vol 2015 ◽  
pp. 1-5 ◽  
Author(s):  
Veronika Vielsmeier ◽  
Astrid Lehner ◽  
Jürgen Strutz ◽  
Thomas Steffens ◽  
Peter M. Kreuzer ◽  
...  

Objective. The majority of tinnitus patients suffer from hearing loss. But a subgroup of tinnitus patients show normal hearing thresholds in the conventional pure-tone audiometry (125 Hz–8 kHz). Here we explored whether the results of the high frequency audiometry (>8 kHz) provide relevant additional information in tinnitus patients with normal conventional audiometry by comparing those with normal and pathological high frequency audiometry with respect to their demographic and clinical characteristics.Subjects and Methods. From the database of the Tinnitus Clinic at Regensburg we identified 75 patients with normal hearing thresholds in the conventional pure-tone audiometry. We contrasted these patients with normal and pathological high-frequency audiogram and compared them with respect to gender, age, tinnitus severity, pitch, laterality and duration, comorbid symptoms and triggers for tinnitus onset.Results. Patients with pathological high frequency audiometry were significantly older and had higher scores on the tinnitus questionnaires in comparison to patients with normal high frequency audiometry. Furthermore, there was an association of high frequency audiometry with the laterality of tinnitus.Conclusion. In tinnitus patients with normal pure-tone audiometry the high frequency audiometry provides useful additional information. The association between tinnitus laterality and asymmetry of the high frequency audiometry suggests a potential causal role for the high frequency hearing loss in tinnitus etiopathogenesis.


2014 ◽  
Vol 2014 ◽  
pp. 1-4 ◽  
Author(s):  
Nandini Vijaya Singham ◽  
Mimiwati Zahari ◽  
Mohammadreza Peyman ◽  
Narayanan Prepageran ◽  
Visvaraja Subrayan

Background. Our study aimed to investigate an association between ocular pseudoexfoliation (PXF) and sensorineural hearing loss (SNHL) and to compare them with age and sex matched controls without pseudoexfoliation.Method. This was a case-control study of 123 patients which included 68 cases with PXF (at least one eye) and 55 controls without pseudoexfoliation. Pure-tone audiometry (PTA) was done for these patients at sound frequencies taken as important for speech comprehension, that is, 250 Hertz (Hz), 500 Hz, 1000 Hz, and 2000 Hz.Results. There were 41 patients with pseudoexfoliation syndrome (PXE) and 27 with pseudoexfoliative glaucoma (PXEG). The majority of patients with hearing loss (60%;n=51) were PXF patients and the remaining 40%(n=34)were controls. Below average hearing thresholds were significantly higher in the pseudoexfoliation group compared to the control group (P=0.01; odds ratio (OR), 3.00; 95% confidence interval (CI), 1.25–7.19). However, there was no significant difference in the mean hearing threshold levels between the three groups (PXE, PXEG, and controls) in either ear (ANOVA, right ear:P=0.46and left earP=0.36).Conclusion. Our study found an association between PXF and SNHL, confirming that PXF can involve organs in the body other than the eye.


2018 ◽  
Vol 46 (11) ◽  
pp. 4527-4534 ◽  
Author(s):  
Geza Benke ◽  
Christina Dimitriadis ◽  
Berihun M. Zeleke ◽  
Imo Inyang ◽  
Dean McKenzie ◽  
...  

Objective This study was performed to determine whether exposure to personal music players (PMPs) in the immediate morning prior to hearing testing confounds the association between mobile phone use and hearing thresholds of adolescents. Design In this cohort study of cognitive function in year 7 students (median age 13 years, range 11–14), information regarding the weekly use of mobile phones and the use of PMPs was assessed by a questionnaire. Pure-tone audiometry was used to establish hearing thresholds for all participants. Results Among a cohort of 317 adolescents (60.9% females), 130 were unexposed to PMP use while 33 were exposed to PMP use in the morning prior to hearing testing. No statistically significant difference in hearing threshold shifts was found between adolescents who were and were not exposed to PMP use prior to hearing testing. Likewise, the difference in the use of mobile phones according to the PMP use status was not statistically significant. Conclusion Exposure to PMPs prior to hearing testing did not introduce confounding in the present study of mobile phone use and hearing loss among adolescents.


Sign in / Sign up

Export Citation Format

Share Document