Innovative Adhesive Systems for Dental Giomer Restorations

2018 ◽  
Vol 69 (10) ◽  
Author(s):  
Ioana Hodisan ◽  
Cristina Prejmerean ◽  
Tinca Buruiana ◽  
Doina Prodan ◽  
Loredana Colceriu ◽  
...  

The aim of this work was to reduce microleakage in giomer restorations by using innovative materials in both adhesive systems and light-cured dental giomer. Two adhesive systems with different primers were investigated. The innovative compounds in the primers were acrylic acid (AA)/itaconic acid (IA) copolymer modified with methacrylic groups and AA/IA/N-acryloyl-L-leucine copolymer grafted with methacrylic groups. In addition, the investigated new giomer G contains a pre-reacted glass based on the latter copolymer. The commercial Beautifil II giomer and the FL-Bond II adhesive system were used for comparison. Microleakage was evaluated by determining the scores and percentages of dye penetration lengths after thermocycling of a series of light-cured dental giomer restorations performed on 42 premolars extracted for orthodontic reasons. A lower microleakage value was recorded for the adhesive system containing the AA/IA/N-acryloyl-L-leucine copolymer grafted with methacrylic groups than for the commercial adhesive, which was in substantial agreement with SEM and AFM investigations. In this case, remarkable dentin sealing and a strong adhesion at the giomer restoration�tooth interface was observed, and the innovative adhesive was proven to be promising for dental applications.

2016 ◽  
Vol 39 (1) ◽  
pp. 171-180 ◽  
Author(s):  
Juan Carlos Carrillo-Rodríguez ◽  
Héctor Iván Meléndez-Ortiz ◽  
Bertha Puente-Urbina ◽  
Gabriela Padrón ◽  
Antonio Ledezma ◽  
...  

2004 ◽  
Vol 18 (3) ◽  
pp. 253-259 ◽  
Author(s):  
Fabiana Mantovani Gomes França ◽  
Flávio Henrique Baggio Aguiar ◽  
Alex José Souza dos Santos ◽  
José Roberto Lovadino

The aim of this in vitro study was to evaluate quantitatively the microleakage in class V cavities restored with one-bottle and self-etching adhesive systems with and without previous acid etching. Two one-bottle adhesive systems (Single Bond and Prime & Bond 2.1) and one self-etching adhesive system (Clearfil Mega Bond) were used in this study. One hundred and twenty sound human premolar teeth were randomly divided into 6 groups, and 20 class V restorations were prepared in the root dentin to test each bonding system. Each bonding system was used with and without acid etching. Specimens were prepared, dyed with 2% methylene blue, sectioned, triturated, and evaluated with an absorbance spectrophotometer test in order to quantify the infiltrated dye. Results were statistically evaluated by ANOVA and Tukey-Kramer test. No statistically significant differences were found among the adhesive systems when no etching agent was used. However, the Single Bond adhesive system showed statistically significant lower microleakage means than Clearfil Mega Bond and Prime & Bond 2.1 when 37% phosphoric acid was used. Single Bond and Clearfil Mega Bond adhesive systems presented similar behavior when the manufacturers' instructions were followed.


2002 ◽  
Vol 16 (2) ◽  
pp. 115-120 ◽  
Author(s):  
César Augusto Galvão Arrais ◽  
Marcelo Giannini

The formation of a hybrid layer is the main bonding mechanism of current dentin-bonding systems. This study evaluated the morphology and thickness of the resin-infiltrated dentinal layer after the application of adhesive systems. The dentin-bonding agents were evaluated on flat dentinal preparations confected on the occlusal surfaces of human teeth. The test specimens were prepared and inspected under scanning electron microscopy at a magnification of X 2,000. The adhesive systems were responsible for different hybrid layer thicknesses (p < 0.05), and the mean values were: for Scotchbond MP Plus (SM), 7.41 ± 1.24mum; for Single Bond (SB), 5.55 ± 0.82mum; for Etch & Prime 3.0 (EP), 3.86 ± 1.17mum; and for Clearfil SE Bond (CB), 1.22 ± 0.45mum. The results suggest that the conventional three-step adhesive system (SM) was responsible for the thickest hybrid layer, followed by the one-bottle adhesive (SB). The self-etching adhesives, EP and CB, produced the formation of the thinnest hybrid layers.


2007 ◽  
Vol 31 (1) ◽  
pp. 35-40 ◽  
Author(s):  
Carla Miranda ◽  
Luiz Henrique Maykot Prates ◽  
Ricardo de Souza Vieira ◽  
Maria Cristina Marino Calvo

The aims of this study were to evaluate the shear bond strength (SBS) of four adhesive systems applied to primary dentin and enamel and verify, after SBS testing, the failure mode of the adhesive interface. Sixty extracted sound primary molars were selected and crowns were sectioned in a mesial-distal direction. Specimens were randomly assigned into two groups (adhesion to enamel and adhesion to dentin) and then subdivided into four subgroups according to the adhesive system (n=15): Scotchbond Multi-Purpose (SMP) – Single Bond (SB) – Clearfil SE Bond (and Adper Prompt LPop (APL) – SBS tests were performed and the obtained values were statistically analyzed using ANOVA and Tukey tests (p&lt;0.05). The failure mode analysis was performed with a Scanning Electron Microscope (XL-30, Philips). SBS mean values on enamel were [MPa (SD)]: SMP – 27.89 (7.49); SB – 23.92 (8.8); CSB – 24.36 (6.69); APL – 25.96 (4.08); and on dentin: SMP – 17.29 (4.25); SB – 18.2 (8.74); CSB – 16.13 (7.14); APL – 6.04 (3.35). The predominant failure mode was cohesive (primarily of the bonding agent). On enamel SBS was statistically similar for all four adhesives. On dentin SBS of APL was lower than the other tested adhesives.


2016 ◽  
Vol 5 (1) ◽  
pp. 1228-1236 ◽  
Author(s):  
Peng Li ◽  
Songqi Ma ◽  
Jinyue Dai ◽  
Xiaoqing Liu ◽  
Yanhua Jiang ◽  
...  

2009 ◽  
Vol 79 (1) ◽  
pp. 138-143 ◽  
Author(s):  
Sabri Ilhan Ramoglu ◽  
Tancan Uysal ◽  
Mustafa Ulker ◽  
Huseyin Ertas

Abstract Objective: To test the null hypothesis that there is no significant difference between the microleakage of adhesive interferences at the occlusal and gingival margins of both ceramic and metallic brackets bonded with light-cured resin-modified glass ionomer and a conventional adhesive. Materials and Methods: Sixty freshly extracted human maxillary premolar teeth were randomly divided into four groups of 15 teeth each. Metal and ceramic brackets were bonded to groups 1 and 2 with resin-modified glass ionomer adhesive (RMGIA). Metal and ceramic brackets were bonded to group 3 and group 4 with a conventional adhesive (CA) system. A dye-penetration method was used for microleakage evaluation. Microleakage from the occlusal and gingival margins was determined by a stereomicroscope for the enamel-adhesive and bracket-adhesive interfaces. Statistical analysis was performed using the Kruskal-Wallis test and the Mann-Whitney U-test with a Bonferroni correction. Results: The gingival side of all groups exhibited higher microleakage scores compared with the occlusal side for both adhesive interfaces. All bracket and adhesive combinations displayed statistically significant differences in microleakage between the enamel-adhesive and adhesive-bracket interfaces at the occlusal and gingival sides of the brackets (P &lt; .001). When the adhesive systems were compared, the RMGIA showed more microleakage than the CA between the different interfaces. Conclusions: The hypothesis is rejected. RMGIA results in more microleakage between enamel-adhesive interfaces.


2014 ◽  
Vol 62 (4) ◽  
pp. 365-370 ◽  
Author(s):  
Ricardo Alves dos SANTOS ◽  
Eliane Alves de LIMA ◽  
Mônica Maria de Albuquerque PONTES ◽  
Alexandre Batista Lopes do NASCIMENTO ◽  
Marcos Antônio Japiassú Resende MONTES ◽  
...  

OBJECTIVE: To assess the bond strength to dentin of the Single Bond (3M ESPE) and XP Bond (Dentsply) total-etch and Adper SE Plus (3M ESPE) self-etch adhesive systems. METHODS: Fifteen healthy human third molars were randomly allocated across three different groups of five teeth each according to the adhesive system. The occlusal portion of each tooth was removed under refrigeration using a flexible diamond disc (EXTEC, Enfield, CT, USA) down to an area of dentin that did not reveal enamel, as confirmed under a 40X stereo microscope (Ramsor, São Paulo, Brazil). A standardized smear layer was created with #600 grit silicon-carbide paper. The adhesive systems were applied as per manufacturer recommendations, with the exception of the Adper SE Plus system, which was triple-polymerized. Composite resin blocks (5 mm) were placed on the dentin surface. The specimens were stored in distilled water for 24 hours at 37ºC. Using a flexible diamond disc (EXTEC, Enfield, CT, USA), toothpick-like specimens with an adhesive area of less than 1 mm² were obtained. A microtensile bond test was then carried out using a universal testing machine (KRATOS) with a crosshead speed of 0.5 mm/min. Analysis of variance (ANOVA) and Tukey's test were used for comparisons. RESULTS: The bond strength values obtained with each adhesive system were as follows: XP Bond, 96.24 MPa; Adper Single Bond, 72.39 MPa; Adper SE Plus, 49.91 MPa. CONCLUSION: In terms of bond strength to dentin, conventional adhesives outperform self-etching systems.


2004 ◽  
Vol 12 (1) ◽  
pp. 12-17 ◽  
Author(s):  
Linda Wang ◽  
Marília Afonso Rabelo Buzalaf ◽  
Maria Teresa Atta

A dhesive systems associated to resin-modified glass ionomer cements are employed for the achievement of a higher bond strength to dentin. Despite this benefit, other properties should not be damaged. This study aimed at evaluating the short-time fluoride release of a resin-modified glass ionomer cement coated with two one-bottle adhesive systems in a pH cycling system. Four combinations were investigated: G1: Vitremer (V); G2: Vitremer + Primer (VP); G3: Vitremer + Single Bond (VSB) and G4: Vitremer + Prime & Bond 2.1 (VPB). SB is a fluoride-free and PB is a fluoride-containing system. After preparation of the Vitremer specimens, two coats of the selected adhesive system were carefully applied and light-cured. Specimens were immersed in demineralizing solution for 6 hours followed by immersion in remineralizing solution for 18 hours, totalizing the 15-day cycle. All groups released fluoride in a similar pattern, with a greater release in the beginning and decreasing with time. VP showed the greatest fluoride release, followed by V, with no statistical difference. VSB and VPB released less fluoride compared to V and VP, with statistical difference. Regardless the one-bottle adhesive system, application of coating decreased the fluoride release from the resin-modified glass ionomer cements. This suggests that this combination would reduce the beneficial effect of the restorative material to the walls around the restoration.


Soft Matter ◽  
2019 ◽  
Vol 15 (47) ◽  
pp. 9700-9709 ◽  
Author(s):  
Micaela A. Macchione ◽  
M. Florencia Sacarelli ◽  
Ana C. Racca ◽  
Catalina Biglione ◽  
Graciela M. Panzetta-Dutari ◽  
...  

Monodispersed nanogels based on oligo(ethylene glycol) methacrylates and acrylic acid or itaconic acid as candidates for biomedical applications.


2020 ◽  
Vol 2020 ◽  
pp. 1-7
Author(s):  
Mariana Almeida Mello Proença ◽  
Karime Tavares Lima da Silva ◽  
Alisson Costa e Silva ◽  
Edilausson Moreno Carvalho ◽  
José Bauer ◽  
...  

Objectives. The aim of this study was to evaluate the shear bond strength of metal brackets bonded with different universal adhesive systems containing 10-MDP and Transbond Plus Self Etching Primer after 20,000 thermal cycles. Materials and Methods. A total of 130 sound bovine teeth were used, which are divided into 5 groups (n = 26) according to the adhesive system used: All-Bond Universal (Bisco), Ambar Universal (FGM), Clearfil Universal Bond (Kuraray), Single Bond Universal (3M/ESPE), and Transbond Plus SEP (3M/ESPE) as control. The adhesives were applied for 20 seconds and bonded with a resin Transbond XT (3M/ESPE). After this, the teeth were submitted to 20,000 cycles at 5°C and 55°C. Afterwards, the shear bond strength test was performed in a universal test machine (Instron 3342). The adhesive remnant index (ARI) was evaluated under a stereomicroscope at 10x magnification and scanning electronic microscopy (SEM, Hitachi 3030). The shear bond strength data were submitted to One-Way ANOVA (α = 0.05) and the ARI to the Kruskal–Wallis test (α = 0.05). Results. Statistical analysis showed that the universal adhesive systems presented mean shear bond strength values similar to Transbond Plus SEP (p<0.05). The universal adhesive presented similar ARI values among them but differed from those of Transbond Plus SEP (p<0.001). Transbond Plus SEP presented a high ARI value when compared with the universal adhesive systems and high demineralization of enamel. Conclusions. The results show that universal adhesive systems may be used for bonding metal brackets if the orthodontist wants to maintain dental enamel health.


Sign in / Sign up

Export Citation Format

Share Document