Transitioning Hearing Aid Users with Severe and Profound Loss to a New Gain/Frequency Response: Benefit, Perception, and Acceptance

2011 ◽  
Vol 22 (03) ◽  
pp. 168-180 ◽  
Author(s):  
Elizabeth Convery ◽  
Gitte Keidser

Background: Adults with severe and profound hearing loss tend to be long-term, full-time users of amplification who are highly reliant on their hearing aids. As a result of these characteristics, they are often reluctant to update their hearing aids when new features or signal-processing algorithms become available. Due to the electroacoustic constraints of older devices, many severely and profoundly hearing-impaired adults continue to wear hearing aids that provide more low- and mid-frequency gain and less high-frequency gain than would be prescribed by the National Acoustic Laboratories’ revised formula with profound correction factor (NAL-RP). Purpose: To investigate the effect of a gradual change in gain/frequency response on experienced hearing-aid wearers with moderately severe to profound hearing loss. Research Design: Double-blind, randomized controlled trial. Study Sample: Twenty-three experienced adult hearing-aid users with severe and profound hearing loss participated in the study. Participants were selected for inclusion in the study if the gain/frequency response of their own hearing aids differed significantly from their NAL-RP prescription. Participants were assigned either to a control or to an experimental group balanced for aided ear three-frequency pure-tone average (PTA) and age. Intervention: Participants were fitted with Siemens Artis 2 SP behind-the-ear (BTE) hearing aids that were matched to the gain/frequency response of their own hearing aids for a 65 dB SPL input level. The experimental group progressed incrementally to their NAL-RP targets over the course of 15 wk, while the control group maintained their initial settings throughout the study. Data Collection and Analysis: Aided speech discrimination testing, loudness scaling, and structured questionnaires were completed at 3, 6, 9, 12, and 15 wk postfitting. A paired comparison between the old and new gain/frequency responses was completed at 1 and 15 wk postfitting. Statistical analysis was conducted to examine differences between the experimental and control groups and changes in objective performance and subjective perception over time. Results: The results of the study showed that participants in the experimental group were subjectively accepting of the changes to their amplification characteristics, as evidenced by nonsignificant changes in the ratings of device performance over time. Perception of loudness, sound quality, speech intelligibility, and own voice volume did not change significantly throughout the study. Objectively, participants in the experimental group demonstrated poorer speech discrimination performance as the study progressed, although there was no change in objective loudness perception. According to the paired comparison, there was an overall subjective preference for the original gain/frequency response among all participants, although participants in the experimental group did show an increase in preference for the NAL-RP response by the end of the study. Conclusions: Based on the findings of this study, we suggest that undertaking a gradual change to a new gain/frequency response with severely and profoundly hearing-impaired adults is a feasible procedure. However, we recommend that clinicians select transition candidates carefully and initiate the procedure only if there is a clinical reason for doing so. A validated prescriptive formula should be used as a transition target, and speech discrimination performance should be monitored throughout the transition.

2003 ◽  
Vol 14 (02) ◽  
pp. 084-099 ◽  
Author(s):  
Francis K. Kuk ◽  
Lisa Potts ◽  
Michael Valente ◽  
Lidia Lee ◽  
Jay Picirrillo

The present study examined the phenomenon of acclimatization in persons with a severe-to-profound hearing loss. A secondary purpose was to examine the efficacy of a digital nonlinear power hearing aid that has a low compression threshold with expansion for this population. Twenty experienced hearing aid users wore the study hearing aids for three months and their performance with the study hearing aids was evaluated at the initial fitting, one month, and three months after the initial fitting. Performance of their current hearing aids was also evaluated at the initial fitting. Speech recognition testing was conducted at input levels of 50 dB SPL and 65 dB SPL in quiet, and 75 dB SPL in noise at a +10 SNR. Questionnaires were used to measure subjective performance at each evaluation interval. The results showed improvement in speech recognition score at the one-month evaluation over the initial evaluation. No significant improvement was seen at the three-month evaluation from the one-month visit. In addition, subjective and objective performance of the study hearing aids was significantly better than the participants' own hearing aids at all evaluation intervals. These results provided evidence of acclimatization in persons with a severe-to-profound hearing loss and reinforced the precaution that any trial of amplification, especially from linear to nonlinear mode, should consider this phenomenon.


1980 ◽  
Vol 23 (2) ◽  
pp. 470-479 ◽  
Author(s):  
Elmer Owens ◽  
Sharon Fujikawa

Subjects with profound postlingual hearing loss completed the Hearing Performance Inventory (HPI) during the course of their hearing aid evaluations. Comparisons of responses to the HPI were made for (a) subjects who wore hearing aids versus subjects who did not, and (b)hearing aid users with losses greater than 100 dB versus users with losses between 80-100 dB. The former set of comparisons indicated consistently superior performance for the aided group, and the latter set indicated consistently superior performance for the 80-100 dB group. The HPI may be a valuable tool in hearing aid considerations.


2010 ◽  
Vol 21 (03) ◽  
pp. 169-175 ◽  
Author(s):  
Kathy S. Halpin ◽  
Kay Y. Smith ◽  
Judith E. Widen ◽  
Mark E. Chertoff

Background: Universal Newborn Hearing Screening (UNHS) was introduced in Kansas in 1999. Prior to UNHS a small percentage of newborns were screened for and identified with hearing loss. Purpose: The purpose of this study was to determine the effects of UNHS on a local early intervention (EI) program for young children with hearing loss. Research Design: This was a retrospective study based on the chart review of children enrolled in the EI program during target years before and after the establishment of UNHS. Study Sample: Charts for 145 children were reviewed. Data Collection and Analysis: The chart review targeted the following aspects of the EI program: caseload size, percentage of caseload identified by UNHS, age of diagnosis, age of enrollment in EI, degree of hearing loss, etiology of hearing loss, late onset of hearing loss, age of hearing aid fit, percentage of children fit with hearing aids by 6 mo, percentage of children with profound hearing loss with cochlear implants, and percentage of children with additional disabilities. Results: Changes in the EI program that occurred after UNHS were increases in caseload size, percentage of caseload identified by UNHS, percentage of children fit with hearing aids by 6 mo of age, and percentage of children with profound hearing loss with cochlear implants. There were decreases in age of diagnosis, age of enrollment in EI, and age of hearing aid fit. Before UNHS, the majority of children had severe and profound hearing loss; after UNHS there were more children with mild and moderate hearing loss. The percentage of known etiology and late-onset hearing loss was approximately the same before and after UNHS, as was the percentage of children with additional disabilities. Conclusion: UNHS had a positive impact on caseload size, age of diagnosis, age of enrollment in EI, and age of hearing aid fit. The percentage of the caseload identified in the newborn period was about 25% before UNHS and over 80% after its implementation. After UNHS, the EI caseload included as many children with mild and moderate hearing loss as with severe and profound loss. By the last reporting year in the study (academic year 2005–2006) all children with profound hearing losses had cochlear implants.


1980 ◽  
Vol 45 (3) ◽  
pp. 325-335 ◽  
Author(s):  
Jerry L. Punch ◽  
Edwin L. Beck

Connected discourse was processed by a master hearing aid via two channels that were independently adjusted to seven discrete settings of low-cutoff frequency. Signals were tape-recorded and played back in a paired-comparison format to 12 listeners with gradually sloping sensorineural hearing loss, who selected the speech channel preferred for its sound quality. Four experimental trials were administered, each of which consisted of 21 randomized paired conditions. Results across the four trials revealed high intersubject and intrasubject response agreement. Listeners indicated strong and systematic preferences for speech reproduced by circuitry having progressively extended low-frequency emphasis. Findings confirm earlier experimental observations that hearing-impaired listeners are capable of making repeatable paired-comparison preference judgments of the quality of hearing-aid processed speech. Additionally, results demonstrate definitively that low-cutoff frequency is sufficiently robust to be regarded as the probable source of a potent perceptual basis for such judgments. The clinical implication is that hearing-impaired listeners can be expected to exhibit strong preferences for the quality of speech reproduced by hearing aids having relatively extended low-frequency response.


2019 ◽  
Vol 30 (05) ◽  
pp. 346-356 ◽  
Author(s):  
Tian Kar Quar ◽  
Cila Umat ◽  
Yong Yee Chew

AbstractThe use of probe microphone measures in hearing aid verification is often neglected or not fully used by practitioners. Some practitioners rely on simulated gain and output provided by manufacturer's fitting software to verify hearing aids.This study aims to evaluate the effectiveness of manufacturer’s prefit procedure in matching the prescribed real-ear targets. It also aims to study its correlated impact on the predicted speech perception in children with severe and profound hearing loss.This cross-sectional experiment was carried out by measuring the output of hearing aids based on prefit versus real-ear at low-, moderate-, and high-input levels. The predicted speech perception for different hearing aid fittings was determined based on the Speech Intelligibility Index (SII).Sixteen children (28 ears) aged between 4 and 7 yr, with severe to profound sensorineural hearing loss took part in the study.Two different types of hearing aids (Phonak and Unitron) were programmed based on their respective manufacturers’ Desired Sensation Levels (DSL) v5 Child procedure. The hearing aids were then verified using coupler-based measurements and individual real-ear-to-coupler differences. The prefit outputs were compared with the DSL v5 Child–prescribed outputs at low-, moderate-, and high-input levels. The hearing aids were then adjusted to closely match the prescribed output. The SIIs were calculated for the fittings before and after adjustment.Sixty four percent of fittings that were based on the prefit procedure achieved the optimal fit-to-targets, with less than 5-dB RMS deviations from the DSL v5 Child targets. After adjusting the hearing aids to attempt to meet the DSL v5 Child targets, 75% of the ears tested achieved the optimal fit-to-targets. On average, hearing aid outputs generated by the manufacturer’s prefit procedure had good and reasonable agreement with the DSL v5 Child–prescribed outputs at low- and mid-frequencies. Nonetheless, at 4000 Hz, the hearing aid output mostly fell below the DSL v5 Child–prescribed outputs. This was still the case even after the hearing aid was adjusted to attempt to match with the targets. At low input level, some prefit outputs were found to be higher than the prescribed outputs. The deviations of prefit outputs from the prescribed outputs were dependent on the type of hearing aid and input levels. There was no significant difference between the SII calculated for fittings based on the prefit and adjusted fit.Prefit procedure tends to produce outputs that were below the DSL v5 Child–prescribed outputs, with the largest mean difference at 4000 Hz. Even though the hearing aid gains were adjusted to attempt to match with the targets, the outputs were still below the targets. The limitations of hearing aids to match the DSL v5 Child targets at high-frequency region have resulted in no improvement in the children’s predicted speech perception.


2017 ◽  
Vol 96 (7) ◽  
pp. E28-E33 ◽  
Author(s):  
Timothy Mclean ◽  
Irumee Pai ◽  
Andrew Philipatos ◽  
Michael Gordon

We prospectively evaluated the surgical, audiologic, and quality-of-life outcomes in 5 patients—2 men and 3 women, aged 22 to 64 years (mean: 41.8)—who were implanted with the Sophono Alpha 2 MPO Processor. The indications for implantation of this bone-conduction device included recurrent ear canal infections with hearing aids (n = 3), single-sided deafness (n = 1), and patient preference in view of difficulty using a conventional hearing aid (n = 1). In addition to the patient with single-sided deafness, 3 patients had a bilateral mixed hearing loss and 1 had a bilateral conductive hearing loss. Outcomes measures included surgical complications, functional gain (FG), speech discrimination in quiet and noise, and patient satisfaction as determined by the Glasgow Benefit Inventory (GBI) and the Entific Medical Systems bone-anchored hearing aid questionnaire (BAQ). The only postsurgical complication noted was a minor skin reaction and pain in 1 patient that resolved with conservative management. In the 3 patients with the mixed hearing loss, the mean FG was 13.3, 20.0, 11.7, and 11.7 dB at 0.5, 1, 2, and 4 kHz, respectively; in the patient with the bilateral conductive hearing loss, the FG was 10, 25, 10, and 15 dB at the same frequencies. Speech discrimination scores with the Sophono device were comparable to those seen with conventional hearing aids. After implantation, all 5 patients experienced a positive quality-of-life outcome according to the GBI, although 1 of them had only a marginal improvement. On follow-up, all patients reported that they remained satisfied with their implant and that they used their device all day long. We conclude that the Sophono bone-conduction system is a safe and effective option that should be considered for patients with a mixed or conductive hearing loss who are unable to use a conventional hearing aid, as well as for those with single-sided deafness.


Author(s):  
Mohammed Iftekharul Alam ◽  
Kiran Natarajan ◽  
Takhellambam Biram Singh ◽  
Abha Kumari ◽  
Mohan Kameswaran

<p class="abstract"><strong>Background:</strong> <span lang="EN-IN">Advanced otosclerosis affects approximately 10% of patients with otosclerosis. Ossification of the cochlea increases with the course of the disease and may cause sensori-neural or mixed hearing loss. Hearing aids, stapedotomy and cochlear implants are management options for hearing loss associated with advanced otosclerosis. </span></p><p class="abstract"><strong>Methods:</strong> <span lang="EN-IN">A retrospective study of 153 patients with advanced otosclerosis was done in a tertiary ENT centre. 110 patients with advanced otosclerosis underwent stapedotomy and 43 patients with advanced otosclerosis underwent cochlear implantation (CI) from 1997 till date. Exclusion criteria included patients with profound hearing loss from causes other than otosclerosis. The aim was to study the indications, selection criteria, as well as surgical issues of stapedotomy and cochlear implantation in patients with advanced otosclerosis.  </span></p><p class="abstract"><strong>Results:</strong> <span lang="EN-IN">Stapedotomy followed by use of hearing aid was found to give good outcomes in advanced otosclerosis. Patients with advanced otosclerosis who had poor pre-operative speech discrimination underwent CI. Complete insertion was possible in 39 patients and partial insertion was done in 4 patients. The outcomes of cochlear implantation were found to be satisfactory. Facial nerve stimulation was seen in 5 patients who underwent CI; however this was successfully managed by reprogramming or switching off the concerned electrodes. </span></p><p class="abstract"><strong>Conclusions:</strong> <span lang="EN-IN">In our experience, stapedotomy or CI in advanced otosclerosis has proven successful, with a low complication rate. The selection criteria for stapedotomy versus CI have to be stringent for optimal outcomes.</span></p>


1976 ◽  
Vol 41 (4) ◽  
pp. 464-476 ◽  
Author(s):  
Randall C. Beattie ◽  
Bradly J. Edgerton

In spite of criticism, monosyllabic discrimination tests are widely employed for hearing aid selection. The current study was designed to investigate the following questions: (1) How reliable is aided speech discrimination of monosyllables in a background of white noise? (2) Can differences among hearing aids be reliably demonstrated by measuring intelligibility of monosyllables in a background of white noise? and (3) Do hearing aids interact with hearing loss? Twenty subjects with mild-moderate sensorineural hearing losses participated in two experimental sessions. Four hearing aids were evaluated using the NU-6 monosyllables in a background of white noise (s/n = +20 dB). Since the standard deviation of the test-retest differences was 6%, differences between aids were not considered significant unless they exceeded 12%. An interaction between subjects and hearing aids was found; that is, the best aid for one person was not the best for all. Measuring monosyllabic word intelligibility in a background of white noise does not reliably identify a single best aid. However, one or more inferior aids were consistently eliminated in 80% of the subjects.


1996 ◽  
Vol 110 (21) ◽  
pp. 13-20 ◽  
Author(s):  
H. R. Cooper ◽  
S. P. Burrell ◽  
R. H. Powell ◽  
D. W. Proops ◽  
J. A. Bickerton

AbstractThe Birmingham bone anchored hearing aid team is part of the Birmingham osseointegrated programme. In the first seven years of its existence it has received 309 referrals. Twenty-six per cent had suffered a congenital conductive hearing loss and 74 per cent had an acquired conductive hearing loss; the majority secondary to chronic suppurative otitis media.This report is of 68 out of 106 adults wearing bone anchored hearing aids (BAHAs). Ninety-eight per cent showed audiological improvement with the congenital group demonstrating marginally the best freefield thresholds and speech discrimination. Questionnaire data as to the patient experience confirms the benefits especially hearing in noise, and comfort, and the vast majority were more satisfied with the bone anchored hearing aid than their previous aid.