scholarly journals Qualitative and Quantitative Comparison of Hemodynamics Between MRI Measurement and CFD Simulation on Patient-specific Cerebral Aneurysm – A Review

Author(s):  
Lim Sheh Hong ◽  
Mohd Azrul Hisham Mohd Adib ◽  
Mohd Shafie Abdullah ◽  
Radhiana Hassan
CFD letters ◽  
2020 ◽  
Vol 12 (10) ◽  
pp. 1-14
Author(s):  
Lim Sheh Hong ◽  
Mohd Azrul Hisham Mohd Adib ◽  
Mohd Shafie Abdullah ◽  
Nur Hartini Mohd Taib ◽  
Radhiana Hassan ◽  
...  

The recent diagnostic assessment of cerebrovascular disease makes use of computational fluid dynamics (CFD) to quantify blood flow and determine the hemodynamics factors contributing to the disease from patient-specific models. However, compliant and anatomical patient-specific geometries are generally reconstructed from the medical images with different threshold values subjectively. Therefore, this paper tends to present the effect of extracted geometry with different threshold coefficient, Cthres by using a patient-specific cerebral aneurysm model. A set of medical images, digital subtraction angiography (DSA) images from the real patient diagnosed with internal carotid artery (ICA) aneurysm was obtained. The threshold value used to extract the patient-specific cerebral aneurysm geometry was calculated by using a simple threshold determination method. Several threshold coefficients, Cthres such as 0.2, 0.3, 0.4, 0.5 and 0.6 were employed in the image segmentation creating three-dimensional (3D) realistic arterial geometries that were then used for CFD simulation. As a result, we obtained that the volume of patient-specific cerebral aneurysm geometry decreases as the threshold coefficient, Cthres increases. There is dislocation of artery attached to the ICA aneurysm geometry occurred at a high threshold coefficient, Cthres. Besides, the physical changes also bring remarkable physiological effect on the wall shear stress (WSS) distribution and velocity flow field at patient-specific cerebral aneurysm geometry reconstructed with different threshold coefficient, Cthres.


2021 ◽  
Vol 140 ◽  
pp. 111774
Author(s):  
Mohammad Reza Khazdair ◽  
Zahra Gholamnezhad ◽  
Ramin Rezaee ◽  
Mohammad Hossein Boskabady

1976 ◽  
Vol 6 (4) ◽  
pp. 383-393 ◽  
Author(s):  
FRANCOIS B. MICHEL ◽  
PIERRE COUR ◽  
LYNE QUET ◽  
JEAN P. MARTY

2019 ◽  
Vol 11 (10) ◽  
pp. 999-1003 ◽  
Author(s):  
Michael R Levitt ◽  
Christian Mandrycky ◽  
Ashley Abel ◽  
Cory M Kelly ◽  
Samuel Levy ◽  
...  

ObjectivesTo study the correlation between wall shear stress and endothelial cell expression in a patient-specific, three-dimensional (3D)-printed model of a cerebral aneurysm.Materials and methodsA 3D-printed model of a cerebral aneurysm was created from a patient’s angiogram. After populating the model with human endothelial cells, it was exposed to media under flow for 24 hours. Endothelial cell morphology was characterized in five regions of the 3D-printed model using confocal microscopy. Endothelial cells were then harvested from distinct regions of the 3D-printed model for mRNA collection and gene analysis via quantitative polymerase chain reaction (qPCR.) Cell morphology and mRNA measurement were correlated with computational fluid dynamics simulations.ResultsThe model was successfully populated with endothelial cells, which survived under flow for 24 hours. Endothelial morphology showed alignment with flow in the proximal and distal parent vessel and aneurysm neck, but disorganization in the aneurysm dome. Genetic analysis of endothelial mRNA expression in the aneurysm dome and distal parent vessel was compared with the proximal parent vessels. ADAMTS-1 and NOS3 were downregulated in the aneurysm dome, while GJA4 was upregulated in the distal parent vessel. Disorganized morphology and decreased ADAMTS-1 and NOS3 expression correlated with areas of substantially lower wall shear stress and wall shear stress gradient in computational fluid dynamics simulations.ConclusionsCreating 3D-printed models of patient-specific cerebral aneurysms populated with human endothelial cells is feasible. Analysis of these cells after exposure to flow demonstrates differences in both cell morphology and genetic expression, which correlate with areas of differential hemodynamic stress.


Psihologija ◽  
2008 ◽  
Vol 41 (2) ◽  
pp. 195-211
Author(s):  
Jasmina Vuksanovic ◽  
Milena Djuric

Fluency tests are frequently used in clinical practice to asses executive functions. The literature data are not unequivocal although in a great number of papers is pointed out the importance of the left hemisphere, specially of the left frontal lobes in the mediation of phonological fluency and the right hemisphere in the mediation of nonverbal fluency. This paper considers the suitability of fluency tests for the detection of left versus right seizure laterality. The sample consisted of thirty-two epilepsy patients divided into two groups: LHF-participants with the seizure focus in the left hemisphere (n=16), and DHF-participants with the seizure focus in the right hemisphere (n=16), and K-the control group of t age-matched healthy children (n=50) aged 7-11 years. The qualitative and quantitative comparison of the phonological and nonverbal fluency performance was carried out in consideration of the seizure laterality as well as compared to the healthy controls. The results of phonological fluency performance revealed that the performance of the LHF group was significantly reduced as compared to both DHF and K group. The analysis of nonverbal fluency performance revealed that the performance of the DHF group was significantly reduced as compared to both LHF and K group The qualitative analysis obtained valuable data, which could additionally contribute to the neuropsychological evaluation of the left versus right seizure laterality.


Author(s):  
Rajanikanth Rao Vedula ◽  
Shah Mohammed Abdul Khader ◽  
Raghuvir Pai ◽  
Anurag Ayachit ◽  
Kamarul Arifin Ahmad ◽  
...  

2008 ◽  
pp. 738-754
Author(s):  
Matteo Golfarelli ◽  
Stefano Rizzi

Though in most data warehousing applications no relevance is given to the time when events are recorded, some domains call for a different behavior. In particular, whenever late measurements of events take place, and particularly when the events registered are subject to further updates, the traditional design solutions fail in preserving accountability and query consistency. In this article, we discuss the alternative design solutions that can be adopted, in presence of late measurements, to support different types of queries that enable meaningful historical analysis. These solutions are based on the enforcement of the distinction between transaction time and valid time within the schema that represents the fact of interest. Besides, we provide a qualitative and quantitative comparison of the solutions proposed, aimed at enabling wellinformed design decisions.


Sign in / Sign up

Export Citation Format

Share Document