Soil Profile and Ground Properties Influence on Vertical Ground Heat Exchanger Efficiency
Soil properties have a significant impact on the performance of ground heat exchangers. Exchangers cooperating with heat pumps are a reliable and efficient source of renewable energy. In the article concentric vertical ground heat exchanger is analysed, which is a common application cooperating with heat pumps. Soil and ground properties have great im-portance during sizing the system, i.e.: determining the length, configuration and deployment of ground heat exchangers. With the depth the soil/ground type and its properties can change significantly. In addition, occurrence of a ground water can influence physical and thermal properties. Determination of soil type present at different depths in a specific location is possible by performing a soil profile. The article presents an analysis of the impact of two soil profiles on the efficien-cy of the vertical ground heat exchanger. The analysis was performed based on the model of a single heat exchanger made using CFD (Computational Fluid Dynamics) program. The model is divided into two parts: model of heat ex-changer together with grout filling the borehole, second: axis-symmetric model of the ground surrounding the exchanger. Both models are coupled by first-type boundary condition. Simulations of ground heat exchanger work are made for a part of heating season period. The calculation results were compared to reference one with uniform ground profiles. Dif-ference in heat rejected form ground in two analysed does not show high influence of ground layers on ground heat ex-changer performance. On the other hand, results strongly depends on analysed soil profile.