A Study on the Structural Performance of New Shape Built-up Square Column under Concentric Axial Load

Author(s):  
Sun-Hee Kim ◽  
Sung-Mo Choi ◽  
Kyong-Soo Yom
Author(s):  
Takahiro Kume ◽  
Takashi Fujinaga ◽  
Yuping Sun

In this paper, structural performance of damaged SRC beam-columns with open-web type of batten steel plate after retrofitting was investigated. Three open-web type SRC beam-columns with bolt-connected batten steel plates were fabricated and tested under combined constant axial load and cyclic lateral load. At first, each beam-column was cyclically loaded to the targeted displacement. After the first loading, the test columns were retrofitted and reloaded till large deformation or failure. The damaged portion of each column was retrofitted with the polymer cement mortar and epoxy resin was injected into the cracks. The measured stiffness of retrofitted columns varied between 71.4% and 85.5% of the initial one. And, test results also indicated that the column which experienced the larger displacement and higher axial load showed lower load carrying capacity, but the others showed approximately the same capacities as the initial columns. Numerical analysis was also conducted to explain the retrofitted columns. Analytical results predicted the experimental behavior fairly well, which verifies the validity of the analytical models in low axial load.


2013 ◽  
Vol 634-638 ◽  
pp. 2746-2751 ◽  
Author(s):  
Noridah Mohamad ◽  
Najmuddin Hassan

The progressive research upon the issue on renewal technology that can improve the construction industry has initiated the study of Precast Lightweight Foam Concrete Sandwich Panel (PLFP) as an alternative to Industrialize Building System (IBS). This paper reports the analysis of structural behavior of PLFP with double shear connectors under axial load. The PLFP panel consists of two wythes which enclosed a layer of polystyrene layer. Six (6 mm) rebar was used as the vertical and horizontal reinforcement and 9 mm steel bar bent at 450 was used as the connector. Full scaled panel was tested under axial load till failure. It was found that PLFP panel with double shear truss connector has higher ultimate strength capacity compared to PLFP with single shear connectors ehen tested under axial load.


2018 ◽  
Vol 22 (4) ◽  
pp. 1179-1192 ◽  
Author(s):  
Y. H. Mugahed Amran ◽  
Raizal S. M. Rashid ◽  
Farzad Hejazi ◽  
A. A. Abang Ali ◽  
Nor Azizi Safiee ◽  
...  

2021 ◽  
Author(s):  
Antonio Taormina

Double skin composite walls (DSCWs) consist of two skins of profiled steel sheeting and in-fill of concrete. DSCWs are proposed to act as axial and lateral load resisting elements in buildings. This research concentrates on the structural performance of DSCWs made of high performance concretes (HPCs) subjected to elevated temperatures of 800


2017 ◽  
Vol 134 ◽  
pp. 185-198 ◽  
Author(s):  
Noridah Mohamad ◽  
Wan Inn Goh ◽  
Redzuan Abdullah ◽  
Abdul Aziz Abdul Samad ◽  
Priyan Mendis ◽  
...  

2021 ◽  
Author(s):  
Antonio Taormina

Double skin composite walls (DSCWs) consist of two skins of profiled steel sheeting and in-fill of concrete. DSCWs are proposed to act as axial and lateral load resisting elements in buildings. This research concentrates on the structural performance of DSCWs made of high performance concretes (HPCs) subjected to elevated temperatures of 800


Sign in / Sign up

Export Citation Format

Share Document