Eccentric Compressive Strength of High Strength Steel Octagonal Tube Stub Columns

Author(s):  
Han Fang ◽  
Tak-ming Chan ◽  
Ben Young
2012 ◽  
Vol 24 (1) ◽  
pp. 23-34 ◽  
Author(s):  
Cheol-Ho Lee ◽  
Dae-Kyung Kim ◽  
Kyu-Hong Han ◽  
Jin-Ho Kim ◽  
Seung-Eun Lee ◽  
...  

2018 ◽  
Vol 2018 ◽  
pp. 1-13 ◽  
Author(s):  
Hyung-Suk Jung ◽  
Baek-Il Bae ◽  
Hyun-Ki Choi ◽  
Joo-Hong Chung ◽  
Chang-Sik Choi ◽  
...  

This study was conducted to evaluate the applicability of concrete-filled steel tube (CFT) columns made from high-performance construction materials. KBC2016, South Korea’s current building code, limits the maximum compressive strength of concrete at 70 MPa and the maximum yield strength of steel at 650 MPa. Similar restrictions to material properties are imposed on major composite structural design parameters in other countries worldwide. With the recent acceleration of the pace of development in the field of material technology, the compressive strength of commercial concrete has been greatly improved and the problem of low tensile strength, known to be the major limitation of concrete, is being successfully addressed by adding fiber reinforcement to concrete. Therefore, the focus of this study was to experimentally determine the strength and ductility enhancement effects, which depend on material composition. To this end, we performed concentric axial loading tests on CFT stub columns made from steel with a yield strength of 800 MPa and steel fiber-reinforced high-strength concrete. By measuring the strain at the yield point of CFT steel during the test, we could determine whether steel yields earlier than ultimate failure load of the member, which is a key design concept of composite structures. The analysis results revealed that the yield point of steel preceded that of concrete on the stress-strain curve by the concurrent action of the strain increase at the maximum strength, attributable to the high compressive strength and steel fiber reinforcement, and the strain increase induced by the confining stress of the steel tube. Additionally, we performed parametric study using ABAQUS to establish the broad applications of CFT using high-performance materials, with the width-to-thickness ratio as the main parameter. Parametric study was undertaken as experimental investigation was not feasible, and we reviewed the criteria for limiting the width-to-thickness ratio as specified in the current building code.


2013 ◽  
Vol 372 ◽  
pp. 215-218 ◽  
Author(s):  
Hye Ran Kim ◽  
Seung Ju Han ◽  
Hyun Do Yun

This paper describes the experimental results of 70 MPa high strength steel fiber reinforced concrete (SFRC) with different steel fiber volume fractions in compression. The effect of steel fiber on fresh properties, compressive strength, toughness index, cracking procedure of high strength steel fiber concrete is also investigated. The steel fibers were added as the volume fractions of 0%, 0.5%, 1.0%, 1.5% and 2.0%. The cylindrical specimens with Φ100 x 200 for compressive tests were manufactured in accordance with ASTM C 39[. The experimental results showed that the slump of fresh SFRC was inversely proportional to the fiber volume fraction added to high strength concrete. As the addition of steel fiber increased, compressive strength of SFRC decreased. Inclusion of steel fiber improves compressive toughness of high strength SFRC.


2020 ◽  
Vol 157 ◽  
pp. 107078
Author(s):  
Meini Su ◽  
Yancheng Cai ◽  
Xuerui Chen ◽  
Ben Young

2021 ◽  
Vol 179 ◽  
pp. 106536
Author(s):  
Yancheng Cai ◽  
Meini Su ◽  
Xuerui Chen ◽  
Ben Young

2021 ◽  
Vol 169 ◽  
pp. 108422
Author(s):  
Andi Su ◽  
Ke Jiang ◽  
Yating Liang ◽  
Ou Zhao

Sign in / Sign up

Export Citation Format

Share Document