Modeling of Gelatin-Based Head Phantom Based on its Electrical Properties for Wideband Microwave Imaging Application

2015 ◽  
Vol 781 ◽  
pp. 608-611 ◽  
Author(s):  
Mohd Sollehudin Md Said ◽  
Norhudah Seman ◽  
Noor Redzuan Sulaiman ◽  
Tharek Abd Rahman

This article presents a human head phantom characterization based on the study of its electrical properties across 1 to 6 GHz. The study focuses on the grey matter, white matter, cerebral spinal fluid (CSF), blood and skin of human head. Through the investigation and study of the human head characteristics, its phantom can be modeled using simple and common materials, which are gelatin, water and sugar. The electrical properties of the chosen mixtures of materials mimicking the electrical properties of human head are measured using special dielectric probe connected to a vector network analyser (VNA). This human head phantom later can be applied in the microwave imaging system for a further study on the health monitoring of human body.

2015 ◽  
Vol 73 (6) ◽  
Author(s):  
Mohd Sollehudin Md Said ◽  
Norhudah Seman ◽  
Haliza Jaafar

Characterization of phantom material based on its electrical properties across 1 to 6 GHz is investigated and presented in purpose for modelling of a human head phantom. This article presents five phantom samples mimicking main head tissues, which are the tissue of grey matter, white matter, cerebral spinal fluid (CSF), blood and skin. The preparation of phantom samples is performed by using common and cheap materials, which are jelly powder, gelatine, water and sugar. The characteristics of materials used are discussed on the composition ratios and electrical properties. The electrical properties of materials are measured using a special dielectric coaxial probe connected to a vector network analyser (VNA). The obtained data is analysed in terms of relative permittivity,  and conductivity,  for the observation and further discussion on the characterizations. This phantom of the human head tissues later can be applied in the microwave imaging system for a further study on the health monitoring of the human body.


2013 ◽  
Vol 64 (3) ◽  
Author(s):  
Rashidah Che Yob ◽  
Norhudah Seman

This article presents the reflection coefficient measurement by using a wideband multi-port reflectometer for microwave imaging application of human head. The configuration of the proposed wideband multi-port reflectometer is formed by passive components, which are four couplers and two power dividers operating from 1 to 6 GHz. The investigation is successfully done through simulation using the Agilent’s Advanced Design Systems (ADS) software and practical measurement in laboratory. An error correction method with three standards of match, open and short load is then applied to the constructed wideband multi-port reflectometer to remove its imperfect characteristics. The wideband characteristics of proposed reflectometer are analyzed and verified across the designated frequency band.  Its operation in reflection coefficient is tested with the chosen device under test (DUT).


2018 ◽  
Vol 2018 ◽  
pp. 1-12 ◽  
Author(s):  
Reefat Inum ◽  
Md. Masud Rana ◽  
Kamrun Nahar Shushama ◽  
Md. Anwarul Quader

A microwave brain imaging system model is envisaged to detect and visualize tumor inside the human brain. A compact and efficient microstrip patch antenna is used in the imaging technique to transmit equivalent signal and receive backscattering signal from the stratified human head model. Electromagnetic band gap (EBG) structure is incorporated on the antenna ground plane to enhance the performance. Rectangular and circular EBG structures are proposed to investigate the antenna performance. Incorporation of circular EBG on the antenna ground plane provides an improvement of 22.77% in return loss, 5.84% in impedance bandwidth, and 16.53% in antenna gain with respect to the patch antenna with rectangular EBG. The simulation results obtained from CST are compared to those obtained from HFSS to validate the design. Specific absorption rate (SAR) of the modeled head tissue for the proposed antenna is determined. Different SAR values are compared with the established standard SAR limit to provide a safety regulation of the imaging system. A monostatic radar-based confocal microwave imaging algorithm is applied to generate the image of tumor inside a six-layer human head phantom model. S-parameter signals obtained from circular EBG loaded patch antenna in different scanning modes are utilized in the imaging algorithm to effectively produce a high-resolution image which reliably indicates the presence of tumor inside human brain.


Author(s):  
Lulu Wang ◽  
Jinzhang Xu

Previous studies have shown that microwave imaging offers an alternative or additional way for early diagnosis of breast cancer. Microwave antenna plays an important role in a microwave imaging system. The paper presents a wideband microwave antenna for medical microwave breast imaging application. Various simulations were conducted to validate the proposed antenna. Results show that the proposed antenna has the potential for application in a microwave imaging system to identify breast lesions.


2021 ◽  
Vol 11 (1) ◽  
Author(s):  
Mohammad Shahidul Islam ◽  
Mohammad Tariqul Islam ◽  
Ali F. Almutairi

AbstractThis paper presents the preparation and measurement of tissue-mimicking head phantom and its validation with the iteratively corrected coherence factor delay-multiply-and-sum (IC-CF-DMAS) algorithm for brain stroke detection. The phantom elements are fabricated by using different chemical mixtures that imitate the electrical properties of real head tissues (CSF, dura, gray matter, white matter, and blood/stroke) over the frequency band of 1–4 GHz. The electrical properties are measured using the open-ended dielectric coaxial probe connected to a vector network analyzer. Individual phantom elements are placed step by step in a three-dimensional skull. The IC-CF-DMAS image reconstruction algorithm is later applied to the phantom to evaluate the effectiveness of detecting stroke. The phantom elements are preserved and measured multiple times in a week to validate the overall performance over time. The electrical properties of the developed phantom emulate the similar properties of real head tissue. Moreover, the system can also effectively detect the stroke from the developed phantom. The experimental results demonstrate that the developed tissue-mimicking head phantom is time-stable, and it shows a good agreement with the theoretical results in detecting and reconstructing the stroke images that could be used in investigating as a supplement to the real head tissue.


Author(s):  
Renato Cicchetti ◽  
Valentina Cicchetti ◽  
Sandra Costanzo ◽  
Paolo D'Atanasio ◽  
Alessandro Fedeli ◽  
...  

Micromachines ◽  
2021 ◽  
Vol 12 (6) ◽  
pp. 647
Author(s):  
Sameer Alani ◽  
Zahriladha Zakaria ◽  
Tale Saeidi ◽  
Asmala Ahmad ◽  
Muhammad Ali Imran ◽  
...  

Skin cancer is one of the most widespread and fast growing of all kinds of cancer since it affects the human body easily due to exposure to the Sun’s rays. Microwave imaging has shown better outcomes with higher resolution, faster processing time, mobility, and less cutter and artifact effects. A miniaturized elliptical ultra-wideband (UWB) antenna and its semi-spherical array arrangement were used for signal transmission and reception from the defected locations in the breast skin. Several conditions such as various arrays of three, six, and nine antenna elements, smaller tumor, multi-tumors, and skin on a larger breast sample of 30 cm were considered. To assess the ability of the system, a breast shape container with a diameter of 130 mm and height of 60 mm was 3D printed and then filled with fabricated skin and breast fat to perform the experimental investigation. An improved modified time-reversal algorithm (IMTR) was used to recreate 2D images of tumors with the smallest radius of 1.75 mm in any location within the breast skin. The reconstructed images using both simulated and experimental data verified that the system can be a reliable imaging system for skin cancer diagnosis having a high structural similarity index and resolution.


Author(s):  
David O. Rodriguez-Duarte ◽  
Jorge A. Tobon Vasquez ◽  
Rosa Scapaticci ◽  
Lorenzo Crocco ◽  
Francesca Vipiana

Sign in / Sign up

Export Citation Format

Share Document