scholarly journals Comparative Analysis of Exergy and Efficiency for Stratified Thermal Storage Tank with Solar Flat Plate and Evacuated Tube Collectors

2016 ◽  
Vol 855 ◽  
pp. 114-118 ◽  
Author(s):  
Sukruedee Sukchai ◽  
Yodthong Mensin ◽  
Wikarn Wansungnern

In recent years, solar water heating technology has got the major importance in water heating applications. For the efficient and effective working of solar water heaters, storage of the hot water is the main issue in this water heating technologies. This paper mainly presents the exergy and efficiency comparison between the solar flat plate water heater and evacuated tube water heater. A five level stratified thermal storage tank is designed and developed for this analysis. At each level of the tank, temperature of the water is collected for each one hour interval from 9:00 to 16:00 hours in both cases and the overall exergy and efficiency of the two water heaters were calculated. The average efficiency of all the levels for flat plate and evacuated tube collectors are 7.91% and 8.20% respectively. The overall system efficiency is obtained as 39.54% for flat plate and 41.00% for evacuated tube solar collector. At each level exergy is calculate for both systems and the average exergy of all the levels for flat plate collector is 4.243 kW and for evacuated tube solar collector is 4.371 kW.

Climate ◽  
2020 ◽  
Vol 8 (6) ◽  
pp. 78
Author(s):  
Adriana Greco ◽  
Edison Gundabattini ◽  
Darius S. Gnanaraj ◽  
Claudia Masselli

Using TRNSYS software, a comparison of the energy performances of flat-plate collectors (FPCs) and evacuated-tube collectors (ETCs) in domestic solar water heating systems located in different climate areas was carried out in order to ascertain solar energy utilization. Investigations were carried out on single FPCs and ETCs and also for strings of four panels connected in series. Tests were conducted using simulations for water as heat transfer fluid with a fixed fluid flow rate and varying the temperature of the collector’s returning fluid. The maximum power peak decreases with the increase in the inlet temperature of the fluid to the collector in the FPC. The maximum outlet temperature of the FPC is higher than the ETC, most of the time. The evacuated-tube collector performs better only in cold climate areas. Simulations suggest that the use of the FPC is strongly discouraged in cold climatic areas due to thermal losses, whereas the ETC works well with reduced dispersion of heat. In warm seasons, on the contrary, the FPC takes advantage of the high environmental temperature which heats the fluid. The maximum yearly outlet temperature and useful power peak predicted in different climatic areas were investigated by varying the temperature of the fluid inlet fed to the two strings of four FPCs and ETCs. In all cases, the outlet temperature is higher in the ETC technology.


2017 ◽  
Author(s):  
Carola Sánchez ◽  
José Macías ◽  
Jonathan León ◽  
Geancarlos Zamora ◽  
Guillermo Soriano

Passive solar water heating (SWH) is a convenient method to meet domestic hot water requirements in rural areas, where electricity may not be available or fuel supply might be limited due to difficult access. In this work, a low-cost thermosiphon flat-plate solar collector alternative is presented. The design was purposely limited to materials and recyclable products widely available in the local market, such as Tetra Pak, plastic bottles, and polypropylene (PP) fittings and pipes. Since PP is a thermoplastic polymer, a poor heat conductor, it was necessary to ensure a suitable system isolation to obtain an optimum thermal performance, comparable to commercial solar collectors. The design was built and tested in Guayaquil, Ecuadorian coastal city. Six inexpensive temperature sensors were placed at the entrance and exit of the collector, on the flat-plate and inside the hot water storage tank. Data was recorded using an Arduino single-board computer and later analyzed with the data gathered via weather station. The implementation costs of the system are approximately US$300, the overall performance during January 2017 fluctuated between 54% and 23%, and the storage tank temperature range varied from to 46°C to 33°C. Due to its reliability and affordable cost, the SWH system is an attractive alternative to an Ecuadorian commercial solar flat plate collector, which price is set between US$600 and US$700, it has an efficiency around 60%, and the average annual storage tank temperature is 62°C.


2018 ◽  
Vol 37 (3) ◽  
pp. 1147-1161 ◽  
Author(s):  
Esdras Nshimyumuremyi ◽  
Wang Junqi

Solar water heating is a technology of capturing the energy from the sun's radiation for the purpose of raising the temperature of water from water supply temperature to the desired higher temperature depending on the use. There are many views and discussions on the questions of thermal efficiency of solar water heaters and their associated cost, especially different customers/users want to replace their existing conventional water heating energy by solar water heating systems. In this present paper, a deep investigation has been accomplished to determine thermal efficiency and cost analysis of solar water heater made in Rwanda. During manufacturing of solar water heater, the collector was the main part to emphasize on. The high efficiency of the system was achieved by replacing galvanized iron sheet by aluminum sheet slotted and black painted as an absorber plate. The ambient temperature and average solar radiation of the three sites where solar water heaters are installed were investigated. The used materials, specifications and sizing were discussed in this paper.


2014 ◽  
Vol 953-954 ◽  
pp. 111-114
Author(s):  
Sheng Xian Wei ◽  
Fen E Hu ◽  
Dong Yu Li ◽  
Hui Li

Based on the test methods for solar water heating systems, the unsteady thermal efficiency, the daily thermal efficiency and the daily water temperature rise of the balcony-type solar water heating system with a flat-plate solar collector fixed at a large tilt angle (≥60o) have been discussed by the experimental test in Kunming. The results indicate that the average daily thermal efficiencies of the solar collector installed at 60o, 70o, 80o and 90o are around 0.35, 0.39, 0.34 and 0.40. The intercept and the slope of the unsteady thermal efficiency equations are about 0.36~0.44 and 1.62~4.01W·°C-1·m-2. The average daily water temperature rise is 25.2°C, 20.1°C, 18.2°C and 17.4°C for the solar collector fixed at 60o, 70o, 80o and 90o.


Green ◽  
2011 ◽  
Vol 1 (2) ◽  
Author(s):  
Brian Norton

AbstractSolar water heating can be considered to be an established mature technology. The achievement of this status is the outcome of over a century of system development that culminated with a flourish of innovation in the last thirty years. Drivers for research and development have been achieving economic viability by devising systems that, for specific applications in particular climate contexts produced more hot water per unit cost. Reductions in both initial capital and installation costs have been achieved as well as in those associated with subsequent operation and maintenance. Research on solar water heating is discussed with the emphasis on overall systems though some key aspects of component development are also outlined. A comprehensive taxonomy is presented of the generic types of solar water heater that have emerged and their features, characteristics and performance are discussed.


2015 ◽  
Vol 2015 ◽  
pp. 1-7 ◽  
Author(s):  
Jichun Yang ◽  
Qingyang Jiang ◽  
Jingxin Hou ◽  
Chenglong Luo

A novel all-glass evacuated tube collector manifold header with an inserted tube is proposed in this paper which makes water in all-glass evacuated solar collector tube be forced circulated to improve the performance of solar collector. And a dynamic numerical model was presented for the novel all-glass evacuated tube collector manifold header water heater system. Also, a test rig was built for model validation and comparison with traditional all-glass evacuated tube collector. The experiment results show that the efficiency of solar water heater with a novel collector manifold header is higher than traditional all-glass evacuated tube collector by about 5% and the heat transfer model of water heater system is valid. Based on the model, the relationship between the average temperature of water tank and inserted tube diameter (water mass flow) has been studied. The results show that the optimized diameter of inserted tube is 32 mm for the inner glass with the diameter of 47 mm and the water flow mass should be less than 1.6 Kg/s.