Application of the Self-Adjusting Fuzzy Control in Water System of Central Air-Conditioner for Saving Energy

2014 ◽  
Vol 1070-1072 ◽  
pp. 2010-2016 ◽  
Author(s):  
Yuan Yuan Zhang ◽  
Yu Nong Shen

Central air conditioning system with multi variable, nonlinear, time-varying, large time-delay characteristics using the traditional control strategy is difficult to control and good energy saving effect. For these features of central air conditioning system, self-adjustment fuzzy controller is studied based on the fuzzy controller. The simulation can be seen, the self-adjustment fuzzy controller has a faster response speed and smaller steady-state error, while there is a certain adaptive capacity. Its control performance is superior to conventional control strategies and conventional fuzzy controller. Central air-conditioning system uses the parameter self-adjusting fuzzy controller strategy combined with inverter technology. According to load changes, central air conditioning water system can automatically real-timely control the pumps to ensure that the comfort of central air-conditioning provided a significant reduction in energy consumption.

2011 ◽  
Vol 374-377 ◽  
pp. 543-546
Author(s):  
Shi Zhong Yang ◽  
Qing Chang Ren ◽  
Xia Li

The variable air volume (VAV) air-conditioning system with its superior energy saving effect has been applied in many developed countries, also drawn more and more attention in China. Due to the characteristics of VAV air-conditioning system are nonlinear, large time lag, strong coupling, multi-variable and multi-disturbance, the control complexity of the VAV system increase greatly. The energy conservation and comfort of the VAV air-conditioning system can not fully been embodied in application. The research on the VAV system has become the hot spot in the science and technology workers, many new methods and strategies have emerged. From the three aspects: the air system, the water system and the large scale system, the paper describes the control strategies, the control methods and the research progress about the VAV air-conditioning system.


2012 ◽  
Vol 204-208 ◽  
pp. 4280-4285 ◽  
Author(s):  
Jian Min Sun ◽  
Chun Dong Zhang ◽  
Ze Yang Zhou

Considering the central air conditioning system is highly susceptible to interferences from external environment, this paper established a dynamic mathematical model for chilled water system with the air conditioning area, fan coil unit and air conditioning area interference factors. Selection of chilled water system as a controlled object, designed the energy saving control system for central air-conditioning. The inputs of PID controller are deviation of actual temperature and setting temperature, and the change rate of the deviation; output is operation frequency of pump. Experiment shows that, PID control system in 90% time operating at a frequency of 10Hz-40Hz, average is 32.5Hz. Compared with no control system, the pump power consumption was reduced 33.9%.In conclusion, PID control in the central air conditioning system have a good energy saving effect.


2012 ◽  
Vol 516-517 ◽  
pp. 1224-1228
Author(s):  
Na Liang ◽  
Rui Li

Due to energy reserves reduces gradually and uneven distribution, all countries pay more and more attention to energy saving and improve the effective utilization of energy, China also attaches great important to this. Energy saving of buildings is a necessary development trend. Air conditioning system as a large important part of building energy consumption has a huge energy-saving potential. This article mainly introduced the related strategies of energy saving in central air conditioning water system from the following three points of view: the water treatment, the cooling tower, and the variable frequency pump.


2014 ◽  
Vol 1039 ◽  
pp. 409-414
Author(s):  
Tao Han ◽  
Xue Feng Lai ◽  
Liang Wen Yan ◽  
Zai Feng Zhang

This paper introduces the components of central air-conditioning system and compares the advantages and disadvantages of the PID control and fuzzy control.Fuzzy control theory and inverter technology are combined to design the Energy-Saving Monitoring System based on the fuzzy control box of STM32F103C8T6,Siemens S7-200 PLC, ABB inverter as the hardware system and interfaces configuration of KingView as the software. Experimental results show that the water system can be variable flow controlled based on the dynamic load, central air-conditioning energy efficiency the COP has greatly improved under the premise of ensuring the comfort of central air-conditioning.


2012 ◽  
Vol 608-609 ◽  
pp. 1097-1105
Author(s):  
Kai Jing Liu ◽  
Qun Li Zhang ◽  
De Ying Li

This article introduces the specific application of central air conditioning chilled water storage technology in the actual central air conditioning engineered reconstruction. The author analyzes the energy-saving effect of application of central air conditioning chilled water storage technology and the economy of central conditioning renovation project. Operation cost comparison shows that water storage air conditioning system saves money more above 35% than conventional air conditioning system.


2017 ◽  
Vol 13 (07) ◽  
pp. 91
Author(s):  
Yecong He ◽  
Min Tan

<span style="font-family: 宋体; font-size: 10pt; mso-fareast-language: ZH-CN; mso-bidi-font-family: 'Times New Roman'; mso-ansi-language: EN-US; mso-bidi-language: AR-SA;" lang="EN-US">U</span><span style="font-family: 'Times New Roman',serif; font-size: 10pt; mso-fareast-font-family: 'Times New Roman'; mso-fareast-language: DE; mso-ansi-language: EN-US; mso-bidi-language: AR-SA;" lang="EN-US">sing wireless sensor networks to collect indoor temperature and humidity data</span><span style="font-family: 宋体; font-size: 10pt; mso-fareast-language: ZH-CN; mso-bidi-font-family: 'Times New Roman'; mso-ansi-language: EN-US; mso-bidi-language: AR-SA;" lang="EN-US">,</span><span style="font-family: 'Times New Roman',serif; font-size: 10pt; mso-fareast-font-family: 'Times New Roman'; mso-fareast-language: DE; mso-ansi-language: EN-US; mso-bidi-language: AR-SA;" lang="EN-US"> a monitoring system is built.</span><span style="font-family: 'Times New Roman',serif; font-size: 10pt; mso-fareast-font-family: 'Times New Roman'; mso-fareast-language: DE; mso-ansi-language: EN-US; mso-bidi-language: AR-SA;" lang="EN-US">According to the data of the central processing unit, the state of the current room is analyzed, and the cooling capacity (heat) and air volume of the central air conditioner are calculated. Meanwhile, this system calculates the relevant fees based on the amount of cold (heat) consumed by each user, and provides a more accurate data base for the central air conditioning system for energy efficiency optimization. The</span><span style="font-family: 'Times New Roman',serif; font-size: 10pt; mso-fareast-font-family: 'Times New Roman'; mso-fareast-language: DE; mso-ansi-language: EN-US; mso-bidi-language: AR-SA;" lang="EN-US">results show that this system can accurately reflect the environmental status of the target room.</span><span style="font-family: 'Times New Roman',serif; font-size: 10pt; mso-fareast-font-family: 'Times New Roman'; mso-fareast-language: DE; mso-ansi-language: EN-US; mso-bidi-language: AR-SA;" lang="EN-US">Therefore, </span><span style="font-family: 'Times New Roman',serif; font-size: 10pt; mso-fareast-font-family: 宋体; mso-fareast-language: ZH-CN; mso-ansi-language: EN-US; mso-bidi-language: AR-SA;" lang="EN-US">it is concluded that </span><span style="font-family: 'Times New Roman',serif; font-size: 10pt; mso-fareast-font-family: 'Times New Roman'; mso-fareast-language: DE; mso-ansi-language: EN-US; mso-bidi-language: AR-SA;" lang="EN-US">the indoor environment monitoring system based on wireless sensor network and embedded technology proposed in this paper is effective and feasible.</span>


2013 ◽  
Vol 860-863 ◽  
pp. 1612-1615
Author(s):  
Zhou Wu ◽  
Fang Yang ◽  
Hui Fang Tian ◽  
Jing Jing Wang

The primary mission of this design is the air conditioning design of a hotel in Guangzhou city. The calculation of cooling load & heat load, division of the air conditioning system and the determination of the scheme, the design of the duct and water system, and the design of the smoke prevention and extraction system are all included. According to the related standard and considering the energy saving and comfort requirements, the air conditioning system are determined through the economic and technological comparison. Primary return air system is used for open office area and dining hall; fan-coil units with fresh air system is adopted for the guest rooms of the hotel; and the VRV system is adopted for the large conference room. The new air in restaurant rooms and the large conference room is handled by full-heat type fresh air exchanger; new air in guest room is handled by air conditioning units.


2011 ◽  
Vol 84-85 ◽  
pp. 743-746
Author(s):  
You Yuan Zhou

An example of a central air-conditioning project of a rebuilt department store is described in this paper. The design of air system, water system, layout and operations for the air conditioning system is presented in this paper. The system is different form ordinary ones because the floor height is lower; so many special considerations must be taken during the design. In addition, the low cost and easy maintenance place an important role in the design. The operational result of the design is promising and it can be referenced by other designers.


2012 ◽  
Vol 170-173 ◽  
pp. 2431-2436
Author(s):  
Yun Fan Zeng ◽  
Min Hui Zhang

This article presents the design of the air conditioning system in the building. In the project, ice storage for cold source and electric boiler thermal storage for heat source are taken while variable primary flow is used for water system. Taking into account the functions of each part, all air and fan coil unit with fresh air system are applied in ventilation system. The design of air exhaust system is introduced. A detail scheme about the annual operational regulation for energy saving is proposed. During the designing process, energy conservation is given enough attention, and the reliability of operation is also ensured.


Sign in / Sign up

Export Citation Format

Share Document