The Applied Research of Real-Time Monitoring System for Earthquake

2010 ◽  
Vol 143-144 ◽  
pp. 837-840
Author(s):  
Ying Li Liu ◽  
Te Liang Yan ◽  
Zhen Jiang

In the vibration isolating foundation buildings, build strong earthquake observation system, at the same time, join the seismic observation to this system, underground observation is carrying along with the observation of the seismic response on the ground and the buildings. The dynamic accelerator-type apparatus applied in the system, comes into being an accelerator-characteristics from 0.05HZ to 50HZ by electronics feeding back, enormously decrease affects of super low frequency interference and the linear and dynamic ranges can suffice the actual functions, avoids obviously errors of displacement-type apparatus in low frequencies, acquires satisfied effects.

Author(s):  
Scot McNeill ◽  
Paul Angehr ◽  
Dan Kluk ◽  
Tomokazu Saruhashi ◽  
Ikuo Sawada ◽  
...  

A method is described for determining quasi-static and dynamic riser angles using measured data typically found in a riser fatigue monitoring system, specifically acceleration and angular rate data. Quasi-static riser inclination and orientation of the inclination plane are determined from the low frequency triaxial accelerations, containing measurement of the gravitational body force. Components of the gravitational body force along the accelerometer axes vary slowly with the riser quasi-static response. The slowly varying Euler angles are determined from the components of gravity along the three axes. Dynamic riser inclination along and transverse to the quasi-static inclination plane are determined by integration of the angular rates, followed by transformation into a coordinate system aligned with the quasi-static inclination plane. The quasi-static and dynamic inclination angles are combined to arrive at the time trace of riser inclination angles. Following implementation of the method in Matlab®, the procedure was validated and the program verified using laboratory test data. A double-gimbaled platform was constructed, on which were mounted a triaxial accelerometer, biaxial angular rate and biaxial inclinometer (reference sensor). A battery of static and dynamic tests was carried out on the platform. Machinists’ levels and angle gauges were used to set the inclination in the various tests. The angles derived from the acceleration and angular rate data were compared to those of the reference inclinometer. Angle estimates were shown to match the reference angles with negligible error. The method was then implemented into the real-time Riser Fatigue Monitoring System (RFMS) aboard the Chikyu drillship. The algorithm was run using data from an emergency disconnect event that occurred in November, 2012. Quasi-static riser inclination angles were quite large due to high currents near the sea surface. Dynamic riser inclination angles proved to be significant due to Vortex Induced Vibration of the lower portion of the riser that immediately followed the disconnect event. It is important to note that the method uses data that is typically already included in real-time riser monitoring systems. Therefore only a software update is required to provide real-time riser angle information. If the method is built into data processing routines for real-time riser monitoring systems, the need for additional instrumentation, such as inclinometers near flex joints, may be circumvented. On the other hand, if inclinometers already exist, the method serves as an independent source of riser angle information at several locations on the riser. The method can also be used to calculate riser and Blow out Preventer (BOP) stack angles from data recorded using stand-alone, battery-powered loggers.


2004 ◽  
Vol 58 ◽  
pp. S28-S30 ◽  
Author(s):  
Takemi Matsui ◽  
Bonpei Takase ◽  
Kousuke Hagisawa ◽  
Makoto Kikuchi ◽  
Minoru Suzuki ◽  
...  

2010 ◽  
Vol 37 (12) ◽  
pp. 3086-3090
Author(s):  
赵天卓 Zhao Tianzhuo ◽  
樊仲维 Fan Zhongwei ◽  
余锦 Yu Jin ◽  
刘洋 Liu Yang ◽  
张雪 Zhang Xue ◽  
...  

2015 ◽  
Vol 1 (1) ◽  
pp. 37-45
Author(s):  
Irwansyah Irwansyah ◽  
Hendra Kusumah ◽  
Muhammad Syarif

Along with the times, recently there have been found tool to facilitate human’s work. Electronics is one of technology to facilitate human’s work. One of human desire is being safe, so that people think to make a tool which can monitor the surrounding condition without being monitored with people’s own eyes. Public awareness of the underground water channels currently felt still very little so frequent floods. To avoid the flood disaster monitoring needs to be done to underground water channels.This tool is controlled via a web browser. for the components used in this monitoring system is the Raspberry Pi technology where the system can take pictures in real time with the help of Logitech C170 webcam camera. web browser and Raspberry Pi make everyone can control the devices around with using smartphone, laptop, computer and ipad. This research is expected to be able to help the users in knowing the blockage on water flow and monitored around in realtime.


2014 ◽  
Author(s):  
Rozaimi Ghazali ◽  
◽  
Asiah Mohd Pilus ◽  
Wan Mohd Bukhari Wan Daud ◽  
Mohd Juzaila Abd Latif ◽  
...  

Author(s):  
Jia Hua-Ping ◽  
Zhao Jun-Long ◽  
Liu Jun

Cardiovascular disease is one of the major diseases that threaten the human health. But the existing electrocardiograph (ECG) monitoring system has many limitations in practical application. In order to monitor ECG in real time, a portable ECG monitoring system based on the Android platform is developed to meet the needs of the public. The system uses BMD101 ECG chip to collect and process ECG signals in the Android system, where data storage and waveform display of ECG data can be realized. The Bluetooth HC-07 module is used for ECG data transmission. The abnormal ECG can be judged by P wave, QRS bandwidth, and RR interval. If abnormal ECG is found, an early warning mechanism will be activated to locate the user’s location in real time and send preset short messages, so that the user can get timely treatment, avoiding dangerous occurrence. The monitoring system is convenient and portable, which brings great convenie to the life of ordinary cardiovascular users.


Sign in / Sign up

Export Citation Format

Share Document